All Rules in HewlettPackard.Servers.ProLiant.WMI Management Pack

 DisplayNameDescriptionIDTargetCategoryEnabledInstance NameCounter NameFrequencyEvent_IDEvent SourceAlert GenerateAlert SeverityAlert PriorityRemotableEvent Log
HewlettPackard.Servers.ProLiant.WMI.Advanced_Memory_Protection_degraded_RuleHP Windows (WMI) Memory degraded.The Advanced Memory Protection (AMP) system is operating with degraded redundancy. The targeted configuration has degraded or is operating with memory modules that have failed or predicted to fail.HewlettPackard.Servers.ProLiant.WMI.Advanced_Memory_Protection_degraded_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIMemoryAlertTrue03HP MemoryTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.ASR_reboot_occurred_RuleHP Windows (WMI) ASR reboot occurred.The system has rebooted from a Automatic Server Recovery (ASR) event.HewlettPackard.Servers.ProLiant.WMI.ASR_reboot_occurred_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessorsAlertTrue01HP SystemTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Controller_battery_status_Failed_RuleHP Windows (WMI) Smart Array Controller battery failed.A Smart Array controller battery status changed to Failed.HewlettPackard.Servers.ProLiant.WMI.Controller_battery_status_Failed_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue08HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Controller_Battery_Status_set_to_Not_fully_Charged_RuleHP Windows (WMI) Smart Array controller battery degraded.A Smart Array controller Battery status has changed to Not Fully Charged.HewlettPackard.Servers.ProLiant.WMI.Controller_Battery_Status_set_to_Not_fully_Charged_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue07HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Controller_redundancy_state_set_to_Active_RuleHP Windows (WMI) Smart Array controller degraded.A Smart Array controller redundancy state has changed from Standby to Active.HewlettPackard.Servers.ProLiant.WMI.Controller_redundancy_state_set_to_Active_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue00HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Controller_status_Error_RuleHP Windows (WMI) Smart Array controller failed.A Smart Array controller status has changed to Error.HewlettPackard.Servers.ProLiant.WMI.Controller_status_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue02HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Cooling_redundancy_lost_RuleHP Windows (WMI) Fan degraded.Cooling redundancy has been lost.HewlettPackard.Servers.ProLiant.WMI.Cooling_redundancy_lost_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMICoolingAlertTrue06HP SensorTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Enable_x2APIC_mode_for_optimal_system_performance_RuleHP Windows (WMI) Enable x2APIC mode for optimal system performance.The system is not configured for optimal performance as its x2APIC mode is currently disabled. Enabling x2APIC allows better performance in the delivery and handling of interrupts, both in hardware and software, thus improving overall system performance.HewlettPackard.Servers.ProLiant.WMI.Enable_x2APIC_mode_for_optimal_system_performance_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettingsAlertTrue08010HP MCHealthTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Ethernet_teams_redundancy_decreased_RuleHP Windows (WMI) NIC teaming degraded.An Ethernet team's redundancy has decreased. A team member has changed to failed or degraded state.HewlettPackard.Servers.ProLiant.WMI.Ethernet_teams_redundancy_decreased_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworksAlertTrue04HP EthernetTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Ethernet_team_lost_redundancy_RuleHP Windows (WMI) NIC teaming failed.An Ethernet team's redundancy status changed to Redundancy Lost. All members of an Ethernet team, except one, are failed.HewlettPackard.Servers.ProLiant.WMI.Ethernet_team_lost_redundancy_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworksAlertTrue05HP EthernetTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Ethernet_team_member_dropped_from_team_RuleHP Windows (WMI) NIC team member dropped.A team member was dropped from the team via the HP Network Configuration Utility (NCU). This is an optional indication that can be disabled via the Ethernet Event Provider settings.HewlettPackard.Servers.ProLiant.WMI.Ethernet_team_member_dropped_from_team_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworksAlertTrue08HP EthernetTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Fan_Degraded_RuleHP Windows (WMI) Fan degraded.A fan has failed.HewlettPackard.Servers.ProLiant.WMI.Fan_Degraded_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMICoolingAlertTrue09HP SensorTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Fan_failed_RuleHP Windows (WMI) Fan failed.A fan has failed.HewlettPackard.Servers.ProLiant.WMI.Fan_failed_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMICoolingAlertTrue03HP SensorTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.FC_System_failed_RuleHP Windows (WMI) FC Storage system failed. A fibre channel port has changed to a failed status.Replace the fibre channel HBA card.HewlettPackard.Servers.ProLiant.WMI.FC_System_failed_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue07HP Fibre ChannelTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.FC_System_link_down_RuleHP Windows (WMI) FC storage system link down.A fibre channel HBA port has changed to a state of link down.Check the FC cabling to this port. Reinsert the FC GBIC if it has been unplugged. Replace FC cabling or the FC GBIC if failure continues.HewlettPackard.Servers.ProLiant.WMI.FC_System_link_down_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue06HP Fibre ChannelTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.HBA_status_Error_RuleHP Windows (WMI) SAS controller failed.A SAS/SATA HBA status has changed to Error.HewlettPackard.Servers.ProLiant.WMI.HBA_status_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue02HP SASTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.HP_Power_Regulator_mode_is_not_in_an_optimal_setting_RuleHP Windows (WMI) HP Power Regulator mode is not in an optimal settingThe HP Power Regulator mode should be set to OS Control modeHewlettPackard.Servers.ProLiant.WMI.HP_Power_Regulator_mode_is_not_in_an_optimal_setting_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettingsAlertTrue08014HP MCHealthTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Interrupt_redirection_mode_should_be_set_to_physical_destination_mode_RuleHP Windows (WMI) Interrupt redirection mode should be set to physical destination modeWhen x2APIC is enabled on DL980 system, the interrupt redirection mode should be set to physical destination mode, which is not the default mode.HewlettPackard.Servers.ProLiant.WMI.Interrupt_redirection_mode_should_be_set_to_physical_destination_mode_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettingsAlertTrue08016HP MCHealthTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Logical_drive_degraded_state_RuleHP Windows (WMI) SAS logical drive degraded.A logical drive is in a degraded state. Device is still servicing I/O, but redundancy may be degraded or lost.HewlettPackard.Servers.ProLiant.WMI.Logical_drive_degraded_state_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0103HP SASTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Logical_drive_in_degraded_multipath_state_RuleHP Windows (WMI) Smart Array logical drive degraded - Multipath.A logical drive is in a degraded state. Multipath support is Lost. Either cable is removed or not configured.HewlettPackard.Servers.ProLiant.WMI.Logical_drive_in_degraded_multipath_state_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0104HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Logical_drive_in_degraded_state_RuleHP Windows (WMI) Smart Array logical drive degraded.A logical drive is in a degraded state. Device is still servicing I/O but redundancy may be degraded or lost.HewlettPackard.Servers.ProLiant.WMI.Logical_drive_in_degraded_state_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0103HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.logical_processor_configuration_should_be_changed_for_optimal_performance_RuleHP Windows (WMI) logical processor configuration should be changed for optimal performance.The system does not have the logical processor configuration set for optimal performance. Either some logical processors are disabled, or processor cores are not evenly enabled across sockets.HewlettPackard.Servers.ProLiant.WMI.logical_processor_configuration_should_be_changed_for_optimal_performance_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettingsAlertTrue00HP MCHealthTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Management_Processor_Reset_Failed_RuleHP Windows (WMI) Management Processor reset failedThe Management Processor has not reset successfully and may not be operational.HewlettPackard.Servers.ProLiant.WMI.Management_Processor_Reset_Failed_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIManagementProcessorsAlertTrue03HP MgmtProcTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Memory_board_error_RuleHP Windows (WMI) Memory board failed.A memory board has an error.HewlettPackard.Servers.ProLiant.WMI.Memory_board_error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIMemoryAlertTrue02HP MemoryTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Memory_module_has_failed_or_is_predicted_to_fail_RuleHP Windows (WMI) Memory failed.A memory module has failed or is predicted to fail.HewlettPackard.Servers.ProLiant.WMI.Memory_module_has_failed_or_is_predicted_to_fail_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIMemoryAlertTrue01HP MemoryTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Network_interface_lost_connectivity_RuleHP Windows (WMI) Network interface failed.A network interface has failed. An Ethernet adapter's status changed from OK to Error, or an Ethernet team's status changed to Error from another state.HewlettPackard.Servers.ProLiant.WMI.Network_interface_lost_connectivity_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworksAlertTrue02HP EthernetTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Network_interface_no_longer_available_RuleHP Windows (WMI) Network interface degraded.A network interface is no longer available. An Ethernet adapter was removed or an Ethernet team or VLAN was removed via the HP Network Configuration Utility (NCU).HewlettPackard.Servers.ProLiant.WMI.Network_interface_no_longer_available_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworksAlertTrue012HP EthernetTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Physical_drive_Error_RuleHP Windows (WMI) SCSI physical drive failed.A SCSI physical drive has a status of Error.HewlettPackard.Servers.ProLiant.WMI.Physical_drive_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue00HP SCSITrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Physical_drive_predictive_failure_RuleHP Windows (WMI) SAS physical drive predictive failure.A physical drive status has changed to Predictive Failure.HewlettPackard.Servers.ProLiant.WMI.Physical_drive_predictive_failure_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue00HP SASTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Physical_drive_secure_erase_RuleHP Windows (WMI) Smart Array physical drive secure erase.A Physical Drive is Currently Offline but operational, Secure Erase is in Progress.HewlettPackard.Servers.ProLiant.WMI.Physical_drive_secure_erase_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0205HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Physical_drive_status_Degraded_RuleHP Windows (WMI) Smart Array physical drive status degraded.A physical drive was not authenticated and could not be valideted to be a genuine HP hard drive.HewlettPackard.Servers.ProLiant.WMI.Physical_drive_status_Degraded_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0312HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Physical_drive_status_Predictive_Failure_RuleHP Windows (WMI) Smart Array physical drive predictive failure.A physical drive status has changed to Predictive Failure.HewlettPackard.Servers.ProLiant.WMI.Physical_drive_status_Predictive_Failure_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue00HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.POST_errors_occurred_RuleHP Windows (WMI) POST errors occurred.Power-On-Self-Test (POST) errors occurred during the last system startup.HewlettPackard.Servers.ProLiant.WMI.POST_errors_occurred_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessorsAlertTrue01001HP SystemTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Power_redundancy_lost_RuleHP Windows (WMI) Power sub-system degraded.Power redundancy has been lost.HewlettPackard.Servers.ProLiant.WMI.Power_redundancy_lost_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIPowerSuppliesAlertTrue01006HP SensorTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Power_supply_failed_RuleHP Windows (WMI) Power supply failed.A power supply has failed.HewlettPackard.Servers.ProLiant.WMI.Power_supply_failed_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIPowerSuppliesAlertTrue01003HP SensorTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Power_supply_input_power_lost_RuleHP Windows (WMI) Power supply input power lost.A power supply has failed input power lost.HewlettPackard.Servers.ProLiant.WMI.Power_supply_input_power_lost_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIPowerSuppliesAlertTrue01009HP SensorTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Processor_deconfigured_RuleHP Windows (WMI) Processor degraded.A processor has been disabled by ROM Based Setup (RBSU).HewlettPackard.Servers.ProLiant.WMI.Processor_deconfigured_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessorsAlertTrue02HP ProcessorTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Processor_failed_RuleHP Windows (WMI) Processor failed.A processor has failed.HewlettPackard.Servers.ProLiant.WMI.Processor_failed_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessorsAlertTrue01HP ProcessorTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SAS_Fan_status_Degraded_RuleHP Windows (WMI) SAS storage system fan degraded.A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there may a problem with one or more of the fans.HewlettPackard.Servers.ProLiant.WMI.SAS_Fan_status_Degraded_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0305HP SASTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SAS_Fan_status_Error_RuleHP Windows (WMI) SAS storage system fan failed.A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.HewlettPackard.Servers.ProLiant.WMI.SAS_Fan_status_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0306HP SASTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SAS_Logical_drive_status_Error_RuleHP Windows (WMI) SAS logical drive failed.A logical drive status has changed to Error.HewlettPackard.Servers.ProLiant.WMI.SAS_Logical_drive_status_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0102HP SASTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SAS_Physical_drive_status_degraded_RuleHP Windows (WMI) SAS physical drive status degraded.A physical drive was not able to be authenticated and could not be validated to be a genuine HP hard drive.HewlettPackard.Servers.ProLiant.WMI.SAS_Physical_drive_status_degraded_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0312HP SASTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SAS_Physical_drive_status_Error_RuleHP Windows (WMI) SAS physical drive failed.A physical drive status has changed to Error.HewlettPackard.Servers.ProLiant.WMI.SAS_Physical_drive_status_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0202HP SASTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SAS_Power_Supply_status_Non_Redundant_RuleHP Windows (WMI) SAS storage system power supply degraded.A Storage Enclosure Power Subsystem status has changed to non-redundant.HewlettPackard.Servers.ProLiant.WMI.SAS_Power_Supply_status_Non_Redundant_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue00HP SASTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SAS_Temperature_sensor_status_Critical_RuleHP Windows (WMI) SAS storage system temperature failed.A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs.HewlettPackard.Servers.ProLiant.WMI.SAS_Temperature_sensor_status_Critical_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0309HP SASTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SAS_Temperature_sensor_status_Warning_Condition_RuleHP Windows (WMI) SAS storage system temperature degraded.A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.HewlettPackard.Servers.ProLiant.WMI.SAS_Temperature_sensor_status_Warning_Condition_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0308HP SASTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SATA_Physical_drive_status_Degraded_RuleHP Windows (WMI) SATA physical drive degraded.A physical drive is degraded.HewlettPackard.Servers.ProLiant.WMI.SATA_Physical_drive_status_Degraded_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0604HP SATATrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SATA_Physical_drive_status_Error_RuleHP Windows (WMI) SATA physical drive failed.A physical drive status has changed to Error.HewlettPackard.Servers.ProLiant.WMI.SATA_Physical_drive_status_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue00HP SATATrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SATA_Physical_drive_status_Predictive_Failure_RuleHP Windows (WMI) SATA physical drive predictive failure.A physical drive status has changed to Predictive Failure.HewlettPackard.Servers.ProLiant.WMI.SATA_Physical_drive_status_Predictive_Failure_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0605HP SATATrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_controller_ASIC_encryption_self_test_status_failedHP Windows (WMI) Smart Array controller ASIC encryption self test failed status.A Smart Array Controller ASIC encryption self test status has changed to Failed because of ASIC encryption self tests failure.HewlettPackard.Servers.ProLiant.WMI.SA_controller_ASIC_encryption_self_test_status_failedHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue014HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_not_configuredHP Windows (WMI) Smart Array controller cache status not configured.A Smart Array Controller Cache status has changed to not configured. This may be caused by a configuration change.HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_not_configuredHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue012HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_status_degradedHP Windows (WMI) Smart Array controller cache status degraded.A Smart Array Controller Cache status has changed to Degraded.HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_status_degradedHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue010HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_status_failedHP Windows (WMI) Smart Array controller cache status failed.A Smart Array Controller Cache status has changed to Failed. The controller has detected a problem with the cache and has failed the cache.HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_status_failedHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue011HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_controller_encryption_CSP_NVRAM_status_detection_failedHP Windows (WMI) Smart Array controller encryption CSP NVRAM status detection failed.A Smart Array Controller encryption CSP NVRAM status has changed to Failed because of CSP NVRAM detection failure.HewlettPackard.Servers.ProLiant.WMI.SA_controller_encryption_CSP_NVRAM_status_detection_failedHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue016HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Fan_status_Degraded_RuleHP Windows (WMI) Smart Array storage system fan degraded.A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there may a problem with one or more of the fans.HewlettPackard.Servers.ProLiant.WMI.SA_Fan_status_Degraded_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0305HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Fan_status_Error_RuleHP Windows (WMI) Smart Array storage system fan failed.A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.HewlettPackard.Servers.ProLiant.WMI.SA_Fan_status_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0306HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_Expanding_RuleHP Windows (WMI) Smart Array Logical drive degraded - Expanding.A logical drive status has changed to Expanding.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_Expanding_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0105HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_Not_yet_availableHP Windows (WMI) Smart Array Logical drive in degraded state - Not yet available.A logical drive status has changed to Not Yet Available.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_Not_yet_availableHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0107HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_Queued_for_ExpansionHP Windows (WMI) Smart Array Logical drive in degraded state - Queued for Expansion.A logical drive status has changed to Queued for Expansion.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_Queued_for_ExpansionHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0106HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_RPI_in_progressHP Windows (WMI) Smart Array Logical drive in degraded state - RPI in progress.A logical drive status has changed to Rapid Parity Initialization in progress.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_RPI_in_progressHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0111HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_RPI_QueuedHP Windows (WMI) Smart Array Logical drive in degraded state - RPI Queued.A logical drive status has changed to Rapid Parity Initialization Queued.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_RPI_QueuedHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0112HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_Degraded_New_Logical_Drive_Key_Rekey_In_ProgressHP Windows (WMI) Smart Array Logical drive status Degraded - New Logical Drive Key Rekey In Progress.A logical drive status has changed to New Logical Drive Key Rekey In Progress.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_Degraded_New_Logical_Drive_Key_Rekey_In_ProgressHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0113HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_Degraded_transforming_from_Unencrypted_to_EncryptedHP Windows (WMI) Smart Array Logical drive status Degraded - transforming from Unencrypted to Encrypted.A logical drive status has changed to transforming from Unencrypted to Encrypted.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_Degraded_transforming_from_Unencrypted_to_EncryptedHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0109HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_error_RuleHP Windows (WMI) Smart Array Logical drive failed.A logical drive status has changed to Error.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0102HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_No_Access_Encrypted_with_Controller_Encryption_Not_EnabledHP Windows (WMI) Smart Array Logical drive status error - No Access - Encrypted with Controller Encryption Not Enabled.A logical drive status has changed to No Access - Encrypted with Controller Encryption Not Enabled.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_No_Access_Encrypted_with_Controller_Encryption_Not_EnabledHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0110HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_No_Access_Encrypted_with_No_Controller_KeyHP Windows (WMI) Smart Array Logical drive status error - No Access - Encrypted with No Controller Key.A logical drive status has changed to No Access- Encrypted with No Controller Key.HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_No_Access_Encrypted_with_No_Controller_KeyHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0108HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Physical_drive_status_Error_RuleHP Windows (WMI) Smart Array physical drive failed.A physical drive status has changed to Error.HewlettPackard.Servers.ProLiant.WMI.SA_Physical_drive_status_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0202HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Power_Supply_status_Non_Redundant_RuleHP Windows (WMI) Smart Array storage system power supply degraded.A Storage Enclosure Power Subsystem status has changed to non-redundant.HewlettPackard.Servers.ProLiant.WMI.SA_Power_Supply_status_Non_Redundant_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue00HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Temperature_sensor_status_Critical_RuleHP Windows (WMI) Smart Array storage system temperature failed.A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs.HewlettPackard.Servers.ProLiant.WMI.SA_Temperature_sensor_status_Critical_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0309HP Smart ArrayTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SA_Temperature_sensor_status_Warning_Condition_RuleHP Windows (WMI) Smart Array storage system temperature degraded.A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.HewlettPackard.Servers.ProLiant.WMI.SA_Temperature_sensor_status_Warning_Condition_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0308HP Smart ArrayTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SCSI_Fan_status_Degraded_RuleHP Windows (WMI) SCSI storage system fan degraded.A fan has failed, but there are enough fans in the fan subsystem to keep the enclosure cool.HewlettPackard.Servers.ProLiant.WMI.SCSI_Fan_status_Degraded_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0305HP SCSITrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SCSI_Fan_status_Error_RuleHP Windows (WMI) SCSI storage system fan failed.A fan has failed and there are not enough fans in the fan subsystem to keep the enclosure cool.HewlettPackard.Servers.ProLiant.WMI.SCSI_Fan_status_Error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0306HP SCSITrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SCSI_HBA_status_error_RuleHP Windows (WMI) SCSI controller failed.A SCSI HBA status has changed to Error.HewlettPackard.Servers.ProLiant.WMI.SCSI_HBA_status_error_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue03HP SCSITrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SCSI_physical_drive_predictive_failure_RuleHP Windows (WMI) SCSI physical drive predictive failure.A SCSI physical drive status is now set to Predictive Failure.HewlettPackard.Servers.ProLiant.WMI.SCSI_physical_drive_predictive_failure_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue08HP SCSITrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SCSI_Power_Supply_status_Non_Redundant_RuleHP Windows (WMI) SCSI storage system power supply degraded.A Storage Enclosure Power Supply status has changed to non-redundant.HewlettPackard.Servers.ProLiant.WMI.SCSI_Power_Supply_status_Non_Redundant_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue00HP SCSITrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SCSI_Temperature_sensor_status_Critical_RuleHP Windows (WMI) SCSI storage system temperature failed.A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs.HewlettPackard.Servers.ProLiant.WMI.SCSI_Temperature_sensor_status_Critical_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0309HP SCSITrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.SCSI_Temperature_sensor_status_Warning_Condition_RuleHP Windows (WMI) SCSI storage system temperature degraded.A Storage Enclosure Temperature sensor Status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.HewlettPackard.Servers.ProLiant.WMI.SCSI_Temperature_sensor_status_Warning_Condition_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorageAlertTrue0308HP SCSITrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.system_configuration_should_be_changed_for_optimal_performance_RuleHP Windows (WMI) system configuration should be changed for optimal performance.The system is not configured for optimal performance as its address mode is currently set to 40-bit instead of the Windows recommended 44-bit mode. In addition to the larger addressable physical address space, the 44-bit mode improves the system performance by generating less address decoding faults. HewlettPackard.Servers.ProLiant.WMI.system_configuration_should_be_changed_for_optimal_performance_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettingsAlertTrue00HP MCHealthTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.System_error_has_been_detected_RuleHP Windows (WMI) System error has been detected ._Description_HewlettPackard.Servers.ProLiant.WMI.System_error_has_been_detected_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettingsAlertTrue08012HP MCHealthTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.system_is_missing_one_or_more_critical_QFEs_RuleHP Windows (WMI) system is missing one or more critical QFEs (Quick Fix Engineerings).Need to update system with critical QFE \%s.HewlettPackard.Servers.ProLiant.WMI.system_is_missing_one_or_more_critical_QFEs_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettingsAlertTrue08013HP MCHealthTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.System_Optimization_Alert_is_disabled_RuleHP Windows (WMI) System Optimization Alert is disabled.The user has disabled System Optimization Alert feature.HewlettPackard.Servers.ProLiant.WMI.System_Optimization_Alert_is_disabled_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettingsAlertTrue08011HP MCHealthTrueWarningHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Temperature_threshold_exceeded_detected_RuleHP Windows (WMI) Temperature threshold exceeded.A temperature sensor has detected that the temperature has exceeded the normal operating range.HewlettPackard.Servers.ProLiant.WMI.Temperature_threshold_exceeded_detected_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMITemperatureSensorsAlertTrue02001HP SensorTrueErrorHighTrueSystem
HewlettPackard.Servers.ProLiant.WMI.Thermal_reboot_occurred_RuleHP Windows (WMI) Thermal reboot occurred.The system has rebooted from a thermal shutdown event.HewlettPackard.Servers.ProLiant.WMI.Thermal_reboot_occurred_RuleHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessorsAlertTrue02HP SystemTrueWarningHighTrueSystem