All Rules in SCUtils.APC.UPS.MP Management Pack

 DisplayNameDescriptionIDTargetCategoryEnabledInstance NameCounter NameFrequencyEvent_IDEvent SourceAlert GenerateAlert SeverityAlert PriorityRemotableEvent Log
SCUtils.APC.UPS.Rule.Collect.UPSIEMProbeHumidityEnvironment Humidity The current Humidity. SCUtils.APC.UPS.Rule.Collect.UPSIEMProbeHumiditySCUtils.APC.UPS.IEMProbePerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.Collect.UPSIEMProbeTempEnvironment temperature The current Temperature. SCUtils.APC.UPS.Rule.Collect.UPSIEMProbeTempSCUtils.APC.UPS.IEMProbePerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.AdvBatteryCapacityUPS Battery CapacityThe remaining battery capacity expressed in percent of full capacity.SCUtils.APC.UPS.Rule.ups.AdvBatteryCapacitySCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.AdvBatteryRunTimeRemainingUPS Battery RunTime RemainingThe UPS battery run time remaining before battery exhaustion.SCUtils.APC.UPS.Rule.ups.AdvBatteryRunTimeRemainingSCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.AdvBatteryTemperatureUPS Battery TemperatureThe current internal UPS temperature expressed in Celsius.SCUtils.APC.UPS.Rule.ups.AdvBatteryTemperatureSCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.AdvInputFrequencyUPS Input FrequencyThe current input frequency to the UPS system in Hz.SCUtils.APC.UPS.Rule.ups.AdvInputFrequencySCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.AdvInputLineVoltageUPS Input Line VoltageThe current utility line voltage in VAC.SCUtils.APC.UPS.Rule.ups.AdvInputLineVoltageSCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.AdvOutputCurrentUPS Output Current The current in amperes drawn by the load on the UPS. the rule disabled by default. SCUtils.APC.UPS.Rule.ups.AdvOutputCurrentSCUtils.APC.UPSPerformanceCollectionFalse00FalseTrue
SCUtils.APC.UPS.Rule.ups.AdvOutputFrequencyUPS Output Frequency The current output frequency of the UPS system in Hz. SCUtils.APC.UPS.Rule.ups.AdvOutputFrequencySCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.AdvOutputLoadUPS Output Load The current UPS load expressed in percent of rated capacity. SCUtils.APC.UPS.Rule.ups.AdvOutputLoadSCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.AdvOutputVoltageUPS Output Voltage The output voltage of the UPS system in VAC. SCUtils.APC.UPS.Rule.ups.AdvOutputVoltageSCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.BasicBattery.TimeOnBatteryUPS Time On Battery The elapsed time since the UPS has switched to battery power. SCUtils.APC.UPS.Rule.ups.BasicBattery.TimeOnBatterySCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Rule.ups.BasicBatteryStatusUPS Basic Battery Status The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsAdvConfigLowBatteryRunTime. SCUtils.APC.UPS.Rule.ups.BasicBatteryStatusSCUtils.APC.UPSPerformanceCollectionTrue00FalseTrue
SCUtils.APC.UPS.Trap.Rule.apcInternalCommunicationFaultUPS Alert trap Rule - An internal UPS communication fault existsSCUtils.APC.UPS.Trap.Rule.apcInternalCommunicationFaultSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.apcInternalCommunicationFaultClearedUPS Alert trap Rule - An internal UPS communication fault no longer existsSCUtils.APC.UPS.Trap.Rule.apcInternalCommunicationFaultClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.apcTestTrapUPS Alert trap Rule - Test SNMP trapSCUtils.APC.UPS.Trap.Rule.apcTestTrapSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.badVoltageUPS Alert trap Rule - The output voltage is not within acceptable rangeSCUtils.APC.UPS.Trap.Rule.badVoltageSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.badVoltageClearedUPS Alert trap Rule - The output voltage has returned to an acceptable levelSCUtils.APC.UPS.Trap.Rule.badVoltageClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.baseFanFailureUPS Alert trap Rule - Base module fan needs repairSCUtils.APC.UPS.Trap.Rule.baseFanFailureSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.batteryOverTemperatureUPS Alert trap Rule - The battery temperature threshold has been violatedSCUtils.APC.UPS.Trap.Rule.batteryOverTemperatureSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.batteryOverTemperatureClearedUPS Alert trap Rule - The battery over temperature has been clearedSCUtils.APC.UPS.Trap.Rule.batteryOverTemperatureClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.batteryPackCommEstablishedUPS Alert trap Rule - UPS is communicating with the external battery packsSCUtils.APC.UPS.Trap.Rule.batteryPackCommEstablishedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.batteryPackCommLostUPS Alert trap Rule - Check installation of external battery packs signal cableSCUtils.APC.UPS.Trap.Rule.batteryPackCommLostSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.bypassPowerSupplyFailureUPS Alert trap Rule - Base module bypass power supply needs repairSCUtils.APC.UPS.Trap.Rule.bypassPowerSupplyFailureSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.calibrationEndUPS Alert trap Rule - The UPS has finished calibratingSCUtils.APC.UPS.Trap.Rule.calibrationEndSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.calibrationStartUPS Alert trap Rule - A battery calibration test has been initiated on the UPSSCUtils.APC.UPS.Trap.Rule.calibrationStartSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.chargerFailureUPS Alert trap Rule - The battery charger has failedSCUtils.APC.UPS.Trap.Rule.chargerFailureSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.chargerFailureClearedUPS Alert trap Rule - The battery charger failure condition has been clearedSCUtils.APC.UPS.Trap.Rule.chargerFailureClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.codeAuthenticationDoneUPS Alert trap Rule - Authentication on agent code image is doneSCUtils.APC.UPS.Trap.Rule.codeAuthenticationDoneSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.communicationEstablishedUPS Alert trap Rule - Communication with the UPS has been establishedSCUtils.APC.UPS.Trap.Rule.communicationEstablishedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.communicationLostUPS Alert trap Rule - Communication to the UPS has been lostSCUtils.APC.UPS.Trap.Rule.communicationLostSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.contactFaultUPS Alert trap Rule - One of the contacts on the Environmental Monitor has changed from its default positionSCUtils.APC.UPS.Trap.Rule.contactFaultSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.contactFaultResolvedUPS Alert trap Rule - A fault on one of the Environmental Monitor contacts has been resolvedSCUtils.APC.UPS.Trap.Rule.contactFaultResolvedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.dischargeClearedUPS Alert trap Rule - A UPS discharge condition has been clearedSCUtils.APC.UPS.Trap.Rule.dischargeClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.gracefulShutdownUPS Alert trap Rule - A graceful shutdown has been initiatedSCUtils.APC.UPS.Trap.Rule.gracefulShutdownSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.hardwareFailureBypassUPS Alert trap Rule - UPS on bypass due to internal faultSCUtils.APC.UPS.Trap.Rule.hardwareFailureBypassSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.humidityThresholdViolation1UPS Alert trap Rule - Probe 1 humidity threshold violatedSCUtils.APC.UPS.Trap.Rule.humidityThresholdViolation1SCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.humidityThresholdViolation2UPS Alert trap Rule - An Environmental Monitor humidity threshold has been violated on probe 2SCUtils.APC.UPS.Trap.Rule.humidityThresholdViolation2SCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.humidityThresholdViolationCleared1UPS Alert trap Rule - An Environmental Monitor humidity threshold violation has been cleared on probe 1SCUtils.APC.UPS.Trap.Rule.humidityThresholdViolationCleared1SCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.humidityThresholdViolationCleared2UPS Alert trap Rule - An Environmental Monitor humidity threshold violation has been cleared on probe 2SCUtils.APC.UPS.Trap.Rule.humidityThresholdViolationCleared2SCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.lowBatteryUPS Alert trap Rule - The UPS batteries are lowSCUtils.APC.UPS.Trap.Rule.lowBatterySCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.onbatterycommunicationLostUPS Alert trap Rule - Communication to the UPS when the UPS is on BatterySCUtils.APC.UPS.Trap.Rule.onbatterycommunicationLostSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.powerRestoredUPS Alert trap Rule - Utility power has been restoredSCUtils.APC.UPS.Trap.Rule.powerRestoredSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.restartAgentUPS Alert trap Rule - Agent restarting as commanded by managerSCUtils.APC.UPS.Trap.Rule.restartAgentSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.returnFromBypassUPS Alert trap Rule - UPS has returned from bypassSCUtils.APC.UPS.Trap.Rule.returnFromBypassSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.returnFromLowBatteryUPS Alert trap Rule - The UPS has returned from a low battery conditionSCUtils.APC.UPS.Trap.Rule.returnFromLowBatterySCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.smartAvrReducingUPS Alert trap Rule - The UPS is reducing the line voltage via SmartTrim(TM)SCUtils.APC.UPS.Trap.Rule.smartAvrReducingSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.smartAvrReducingOffUPS Alert trap Rule - The UPS has returned from SmartTrim(TM)SCUtils.APC.UPS.Trap.Rule.smartAvrReducingOffSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.smartBoostOffUPS Alert trap Rule - The UPS has returned from SmartBoost(TM)SCUtils.APC.UPS.Trap.Rule.smartBoostOffSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.smartBoostOnUPS Alert trap Rule - The UPS has enabled SmartBoost(TM)SCUtils.APC.UPS.Trap.Rule.smartBoostOnSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.smartRelayFaultUPS Alert trap Rule - SmartBoost(TM) or SmartTrim(TM) relay faultSCUtils.APC.UPS.Trap.Rule.smartRelayFaultSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.smartRelayFaultClearedUPS Alert trap Rule - SmartBoost(TM) or SmartTrim(TM) relay fault has been clearedSCUtils.APC.UPS.Trap.Rule.smartRelayFaultClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.softwareBypassUPS Alert trap Rule - UPS on bypass - user setSCUtils.APC.UPS.Trap.Rule.softwareBypassSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.switchedBypassUPS Alert trap Rule - UPS on bypassSCUtils.APC.UPS.Trap.Rule.switchedBypassSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.temperatureThresholdViolation1UPS Alert trap Rule - An Environmental Monitor temperature threshold has been violated on probe 1SCUtils.APC.UPS.Trap.Rule.temperatureThresholdViolation1SCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.temperatureThresholdViolation2UPS Alert trap Rule - An Environmental Monitor temperature threshold has been violated on probe 2SCUtils.APC.UPS.Trap.Rule.temperatureThresholdViolation2SCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.temperatureThresholdViolationCleared1UPS Alert trap Rule - An Environmental Monitor temperature threshold violation has been cleared on probe 1SCUtils.APC.UPS.Trap.Rule.temperatureThresholdViolationCleared1SCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.temperatureThresholdViolationCleared2UPS Alert trap Rule - An Environmental Monitor temperature threshold violation has been cleared on probe 2SCUtils.APC.UPS.Trap.Rule.temperatureThresholdViolationCleared2SCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsBackfeedRelayFaultUPS Alert trap Rule - The backfeed relay has a faultSCUtils.APC.UPS.Trap.Rule.upsBackfeedRelayFaultSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsBackfeedRelayFaultClearedUPS Alert trap Rule - The backfeed relay has a fault clearedSCUtils.APC.UPS.Trap.Rule.upsBackfeedRelayFaultClearedSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsBatteryNeedsReplacementUPS Alert trap Rule - The batteries of the UPS need immediate replacementSCUtils.APC.UPS.Trap.Rule.upsBatteryNeedsReplacementSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsBatteryReplacedUPS Alert trap Rule - A bad battery fault has been clearedSCUtils.APC.UPS.Trap.Rule.upsBatteryReplacedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsBatterySoftBusStartFaultUPS Alert trap Rule - A battery bus soft start fault existsSCUtils.APC.UPS.Trap.Rule.upsBatterySoftBusStartFaultSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsBatterySoftBusStartFaultClearedUPS Alert trap Rule - A battery bus soft start fault exists clearedSCUtils.APC.UPS.Trap.Rule.upsBatterySoftBusStartFaultClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsBatteryTempSensorFaultUPS Alert trap Rule - The battery temperature sensor fault existsSCUtils.APC.UPS.Trap.Rule.upsBatteryTempSensorFaultSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsBatteryTempSensorFaultClearedUPS Alert trap Rule - The battery temperature sensor fault clearedSCUtils.APC.UPS.Trap.Rule.upsBatteryTempSensorFaultClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsBypassRelayFaultUPS Alert trap Rule - A bypass relay has a faultSCUtils.APC.UPS.Trap.Rule.upsBypassRelayFaultSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsBypassRelayFaultClearedUPS Alert trap Rule - A bypass relay has a fault clearedSCUtils.APC.UPS.Trap.Rule.upsBypassRelayFaultClearedSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsCalibrationStackChangedUPS Alert trap Rule - A calibration value in the stack was changedSCUtils.APC.UPS.Trap.Rule.upsCalibrationStackChangedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsCriticalConditionUPS Alert trap Rule - A UPS critical condition was detectedSCUtils.APC.UPS.Trap.Rule.upsCriticalConditionSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsCriticalConditionClearedUPS Alert trap Rule - A UPS critical condition has been clearedSCUtils.APC.UPS.Trap.Rule.upsCriticalConditionClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsDiagnosticsFailedUPS Alert trap Rule - The UPS failed its internal diagnostic self-testSCUtils.APC.UPS.Trap.Rule.upsDiagnosticsFailedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsDiagnosticsPassedUPS Alert trap Rule - The UPS passed its internal self-testSCUtils.APC.UPS.Trap.Rule.upsDiagnosticsPassedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsDipSwitchChangedUPS Alert trap Rule - The dip switch settings on the UPS have been changedSCUtils.APC.UPS.Trap.Rule.upsDipSwitchChangedSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsDischargedUPS Alert trap Rule - The UPS batteries are dischargedSCUtils.APC.UPS.Trap.Rule.upsDischargedSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsEPOActiveUPS Alert trap Rule - Emergency Power Off (EPO) activeSCUtils.APC.UPS.Trap.Rule.upsEPOActiveSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsEPOActiveClearedUPS Alert trap Rule - Emergency Power Off (EPO) now inactiveSCUtils.APC.UPS.Trap.Rule.upsEPOActiveClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsFirmwareMismatchUPS Alert trap Rule - A firmware mismatch error existsSCUtils.APC.UPS.Trap.Rule.upsFirmwareMismatchSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsFirmwareMismatchClearedUPS Alert trap Rule - A firmware mismatch error no longer existsSCUtils.APC.UPS.Trap.Rule.upsFirmwareMismatchClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsFirmwareUpdateFailedUPS Alert trap Rule - UPS firmware update failedSCUtils.APC.UPS.Trap.Rule.upsFirmwareUpdateFailedSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsFirmwareUpdateFinishedUPS Alert trap Rule - Finished updating UPS firmwareSCUtils.APC.UPS.Trap.Rule.upsFirmwareUpdateFinishedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsFirmwareUpdateStartedUPS Alert trap Rule - Updating UPS firmwareSCUtils.APC.UPS.Trap.Rule.upsFirmwareUpdateStartedSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsFirmwareUpdateSucceededUPS Alert trap Rule - UPS firmware update succeededSCUtils.APC.UPS.Trap.Rule.upsFirmwareUpdateSucceededSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsHasNoValidFirmwareUPS Alert trap Rule - UPS has no valid firmwareSCUtils.APC.UPS.Trap.Rule.upsHasNoValidFirmwareSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsHasNoValidFirmwareClearedUPS Alert trap Rule - UPS now has a valid firmwareSCUtils.APC.UPS.Trap.Rule.upsHasNoValidFirmwareClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsInformationalConditionUPS Alert trap Rule - A UPS informational condition has been detectedSCUtils.APC.UPS.Trap.Rule.upsInformationalConditionSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsInformationalConditionClearedUPS Alert trap Rule - A UPS informational condition has been clearedSCUtils.APC.UPS.Trap.Rule.upsInformationalConditionClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsInternalOverTemperatureUPS Alert trap Rule - The internal over temperature condition existsSCUtils.APC.UPS.Trap.Rule.upsInternalOverTemperatureSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsInternalOverTemperatureClearedUPS Alert trap Rule - The internal over temperature condition clearedSCUtils.APC.UPS.Trap.Rule.upsInternalOverTemperatureClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsInverterFaultUPS Alert trap Rule - The inverter fault existsSCUtils.APC.UPS.Trap.Rule.upsInverterFaultSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsInverterFaultClearedUPS Alert trap Rule - The inverter fault clearedSCUtils.APC.UPS.Trap.Rule.upsInverterFaultClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsLocalDisplayButtonFaultUPS Alert trap Rule - A local display button fault existsSCUtils.APC.UPS.Trap.Rule.upsLocalDisplayButtonFaultSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsLocalDisplayButtonFaultClearedUPS Alert trap Rule - A local display button fault no longer existsSCUtils.APC.UPS.Trap.Rule.upsLocalDisplayButtonFaultClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsMpuResetUPS Alert trap Rule - The MPU has been resetSCUtils.APC.UPS.Trap.Rule.upsMpuResetSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsNeedsFactorySetupFaultUPS Alert trap Rule - UPS needs factory setupSCUtils.APC.UPS.Trap.Rule.upsNeedsFactorySetupFaultSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsNeedsFactorySetupFaultClearedUPS Alert trap Rule - UPS no longer needs factory setupSCUtils.APC.UPS.Trap.Rule.upsNeedsFactorySetupFaultClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsOnBatteryUPS Alert trap Rule - The UPS has switched to battery backup powerSCUtils.APC.UPS.Trap.Rule.upsOnBatterySCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsOnBatteryDueToFault UPS Alert trap Rule - The UPS is on battery due to an error. SCUtils.APC.UPS.Trap.Rule.upsOnBatteryDueToFaultSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsOnBatteryDueToFaultClearedUPS Alert trap Rule - The UPS is no longer on battery due to an errorSCUtils.APC.UPS.Trap.Rule.upsOnBatteryDueToFaultClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsOscillatorFailedUPS Alert trap Rule - An oscillator error existsSCUtils.APC.UPS.Trap.Rule.upsOscillatorFailedSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsOscillatorFailedClearedUPS Alert trap Rule - An oscillator error no longer existsSCUtils.APC.UPS.Trap.Rule.upsOscillatorFailedClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsOutletGroupCommandUPS Alert trap Rule - The specified Outlet Group command has been issuedSCUtils.APC.UPS.Trap.Rule.upsOutletGroupCommandSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsOutletGroupTurnedOffUPS Alert trap Rule - The specified Outlet Group turned offSCUtils.APC.UPS.Trap.Rule.upsOutletGroupTurnedOffSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsOutletGroupTurnedOnUPS Alert trap Rule - The specified Outlet Group turned onSCUtils.APC.UPS.Trap.Rule.upsOutletGroupTurnedOnSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsOutputSwitchClosedUPS Alert trap Rule - The Output Switch is closedSCUtils.APC.UPS.Trap.Rule.upsOutputSwitchClosedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsOutputSwitchOpenedUPS Alert trap Rule - The Output Switch is openSCUtils.APC.UPS.Trap.Rule.upsOutputSwitchOpenedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsOverloadUPS Alert trap Rule - The UPS overloadSCUtils.APC.UPS.Trap.Rule.upsOverloadSCUtils.APC.UPSAlertTrue00TrueErrorNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsOverloadClearedUPS Alert trap Rule - The overload condition has been clearedSCUtils.APC.UPS.Trap.Rule.upsOverloadClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsPfcFaultUPS Alert trap Rule - A PFC fault existsSCUtils.APC.UPS.Trap.Rule.upsPfcFaultSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsPfcFaultClearedUPS Alert trap Rule - The PFC fault clearedSCUtils.APC.UPS.Trap.Rule.upsPfcFaultClearedSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsRebootStartedUPS Alert trap Rule - The UPS has started its reboot sequenceSCUtils.APC.UPS.Trap.Rule.upsRebootStartedSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsSleepingUPS Alert trap Rule - The UPS is entering 'sleep' modeSCUtils.APC.UPS.Trap.Rule.upsSleepingSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsTurnedOffUPS Alert trap Rule - The UPS has been turned 'off'SCUtils.APC.UPS.Trap.Rule.upsTurnedOffSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsTurnedOnUPS Alert trap Rule - A UPS is turned onSCUtils.APC.UPS.Trap.Rule.upsTurnedOnSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue
SCUtils.APC.UPS.Trap.Rule.upsWarningConditionUPS Alert trap Rule - A UPS warning condition has been detectedSCUtils.APC.UPS.Trap.Rule.upsWarningConditionSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsWarningConditionClearedUPS Alert trap Rule - A UPS warning condition has been clearedSCUtils.APC.UPS.Trap.Rule.upsWarningConditionClearedSCUtils.APC.UPSAlertTrue00TrueWarningNormalTrue
SCUtils.APC.UPS.Trap.Rule.upsWokeUpUPS Alert trap Rule - The UPS has returned from 'sleep' modeSCUtils.APC.UPS.Trap.Rule.upsWokeUpSCUtils.APC.UPSAlertTrue00TrueInformationLowTrue