| DisplayName | Description | ID | Target | Category | Enabled | Instance Name | Counter Name | Frequency | Event_ID | Event Source | Alert Generate | Alert Severity | Alert Priority | Remotable | Event Log |
| Sample APC PDU Load Status | SCOM Rule that polls and logs APC PDU Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : rPDULoadStatusLoadState
Name
rPDULoadStatusLoadState
Oid
1.3.6.1.4.1.318.1.1.12.2.3.1.1.3.1
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . rPDU . rPDULoad . rPDULoadStatus . rPDULoadStatusTable . rPDULoadStatusEntry . rPDULoadStatusLoadState
Type
Integer
Known Values
phaseLoadNormal (1)
phaseLoadLow (2)
phaseLoadNearOverload (3)
phaseLoadOverload (4)
Access
read-only
Status
mandatory
Description
Getting this OID will return the phase/bank load state.
phaseLoadNormal(1) indicates that the phase/bank is operating properly within the rPDULoadConfigLowLoadThreshold and rPDULoadConfigNearOverloadThreshold OID values.
phaseLoadLow(2) indicates that the phase/bank load has dropped below the rPDULoadConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
phaseLoadNearOverload(3) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
phaseLoadOverload(4) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
| Sample.APC.PDU.Rule.rPDULoadStatusLoadState | Sample.APC.PDU.Device | PerformanceCollection | False | | | 0 | 0 | | False | | | True | |
| Sample APC PDU Power Supply 1 Status | SCOM Rule that polls and logs APC PDU Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : rPDUPowerSupply1Status
Name
rPDUPowerSupply1Status
Oid
1.3.6.1.4.1.318.1.1.12.4.1.1.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . rPDU . rPDUPowerSupply . rPDUPowerSupplyDevice . rPDUPowerSupply1Status
Type
Integer
Known Values
PowerSupply1Ok (1)
PowerSupply1Failed (2)
Access
read-only
Status
mandatory
Description
Getting this OID will return powerSupply1Ok(1) if power supply 1 is functioning normally. If not functioning normally, this OID will return powerSupply1Failed(2).
| Sample.APC.PDU.Rule.rPDUPowerSupply1Status | Sample.APC.PDU.Device | PerformanceCollection | False | | | 0 | 0 | | False | | | True | |
| Sample APC PDU Power Supply 2 Status | SCOM Rule that polls and logs APC PDU Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : rPDUPowerSupply2Status
Name
rPDUPowerSupply2Status
1.3.6.1.4.1.318.1.1.12.4.1.2.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . rPDU . rPDUPowerSupply . rPDUPowerSupplyDevice . rPDUPowerSupply2Status
Type
Integer
Known Values
PowerSupply2Ok (1)
PowerSupply2Failed (2)
Access
read-only
Status
mandatory
Description
Getting this OID will return powerSupply2Ok(1) if power supply 2 is functioning normally. If not functioning normally, this OID will return powerSupply2Failed(2).
| Sample.APC.PDU.Rule.rPDUPowerSupply2Status | Sample.APC.PDU.Device | PerformanceCollection | False | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Battery Capacity | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsAdvBatteryCapacity
Name
upsAdvBatteryCapacity
Oid
1.3.6.1.4.1.318.1.1.1.2.2.1.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsAdvBattery . upsAdvBatteryCapacity
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The remaining battery capacity expressed in percent of full capacity. | Sample.APC.UPS.Rule.upsAdvBatteryCapacity | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Battery RunTime Remaining | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsAdvBatteryRunTimeRemaining
Name
upsAdvBatteryRunTimeRemaining
Oid
1.3.6.1.4.1.318.1.1.1.2.2.3.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsAdvBattery . upsAdvBatteryRunTimeRemaining
Type
TimeTicks
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The UPS battery run time remaining before battery exhaustion. | Sample.APC.UPS.Rule.upsAdvBatteryRunTimeRemaining | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Battery Temperature | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsAdvBatteryTemperature
Name
upsAdvBatteryTemperature
Oid
1.3.6.1.4.1.318.1.1.1.2.2.2.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsAdvBattery . upsAdvBatteryTemperature
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current internal UPS temperature expressed in Celsius. | Sample.APC.UPS.Rule.upsAdvBatteryTemperature | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Input Frequency | SCOM Rule that polls and logs APC UPS Units.
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsAdvInputFrequency
Name
upsAdvInputFrequency
Oid
1.3.6.1.4.1.318.1.1.1.3.2.4.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsInput . upsAdvInput . upsAdvInputFrequency
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current input frequency to the UPS system in Hz. | Sample.APC.UPS.Rule.upsAdvInputFrequency | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Input Line Voltage | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsAdvInputLineVoltage
Name
upsAdvInputLineVoltage
Oid
1.3.6.1.4.1.318.1.1.1.3.2.1.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsInput . upsAdvInput . upsAdvInputLineVoltage
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current utility line voltage in VAC. | Sample.APC.UPS.Rule.upsAdvInputLineVoltage | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Output Current | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsAdvOutputCurrent
Name
upsAdvOutputCurrent
Oid
1.3.6.1.4.1.318.1.1.1.4.2.4.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputCurrent
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current in amperes drawn by the load on the UPS. | Sample.APC.UPS.Rule.upsAdvOutputCurrent | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Output Frequency | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsAdvOutputFrequency
Name
upsAdvOutputFrequency
Oid
1.3.6.1.4.1.318.1.1.1.4.2.2.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputFrequency
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current output frequency of the UPS system in Hz. | Sample.APC.UPS.Rule.upsAdvOutputFrequency | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Output Load | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsAdvOutputLoad
Name
upsAdvOutputLoad
Oid
1.3.6.1.4.1.318.1.1.1.4.2.3.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputLoad
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current UPS load expressed in percent of rated capacity. | Sample.APC.UPS.Rule.upsAdvOutputLoad | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Output Voltage | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsAdvOutputVoltage
Name
upsAdvOutputVoltage
Oid
1.3.6.1.4.1.318.1.1.1.4.2.1.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputVoltage
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The output voltage of the UPS system in VAC. | Sample.APC.UPS.Rule.upsAdvOutputVoltage | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Basic Battery Status | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsBasicBatteryStatus
Name
upsBasicBatteryStatus
Oid
1.3.6.1.4.1.318.1.1.1.2.1.1.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsBasicBattery . upsBasicBatteryStatus
Base-Type
integer
Known-Values
unknown (1) batteryNormal (2) batteryLow (3)
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsAdvConfigLowBatteryRunTime. | Sample.APC.UPS.Rule.upsBasicBatteryStatus | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |
| Sample APC Ups Time On Battery | SCOM Rule that polls and logs APC UPS Units.
References:
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB : upsBasicBatteryTimeOnBattery
Name
upsBasicBatteryTimeOnBattery
Oid
1.3.6.1.4.1.318.1.1.1.2.1.2.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsBasicBattery . upsBasicBatteryTimeOnBattery
Type
TimeTicks
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The elapsed time since the UPS has switched to battery power. | Sample.APC.UPS.Rule.upsBasicBatteryTimeOnBattery | Sample.APC.UPS.Device | PerformanceCollection | True | | | 0 | 0 | | False | | | True | |