| DisplayName | Description | ID | Target | Parent Monitor | Category | Enabled | Instance Name | Counter Name | Frequency | Alert Generate | Alert Severity | Alert Priority | Alert Auto Resolve | Monitor Type | Remotable | Accessibility | RunAs |
| Clustered Data ONTAP MetroCluster: Back Hoe Detection Monitor | A backhoe event is the severing of all communication links that interconnect two partner clusters in a MetroCluster configuration. This monitor checks whether all communication links that interconnect two partner clusters are severed, clusters can still operate independently from each other, and generates a warning event if they are severed. | DataONTAP.Cluster.MetroCluster.MetroCluster.BackHoeMonitor | DataONTAP.Cluster.MetroCluster.MetroCluster | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Health Monitor | The MetroCluster Health Monitor checks the health status of a MetroCluster configuration’s major components such as cluster nodes, aggregates, replication, and LIFs. All these components are either OK or in a warning state. | DataONTAP.Cluster.MetroCluster.MetroCluster.HealthMonitor | DataONTAP.Cluster.MetroCluster.MetroCluster | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Intercluster Connection Status Monitor | The two clusters in a MetroCluster configuration are peered via a customer-provided cluster peering network. Intercluster LIFs must be configured on each node in the MetroCluster configuration and the clusters must be configured for peering. The ports with the intercluster LIFs are used to connect to the customer-provided cluster peering network. This monitor generates an alert if the connection status is in a warning or critical state. | DataONTAP.Cluster.MetroCluster.MetroCluster.InterclusterConnectionStatusMonitor | DataONTAP.Cluster.MetroCluster.MetroCluster | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: MetroCluster Storage FCP Adapter Status Monitor | The MetroCluster Storage FCP Adapter Status Monitor checks the state of FC initiator adapter ports. | DataONTAP.Cluster.MetroCluster.MetroCluster.StorageFcpAdapterStatus | DataONTAP.Cluster.MetroCluster.MetroCluster | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: SwitchBack Effect Monitor | The MetroCluster switchback operation returns a MetroCluster configuration to its normal operating state. This monitor checks that after a switchback operation, all aggregates or disks left behind have been restored to their owner. The monitor generates an alert if they are not fully restored. A check is done at the end of a switchback operation to ensure that all aggregates or volumes came back online but an administrator can override this check. The administrator can manually reassign disks to replace any missing disks that were not reassigned. | DataONTAP.Cluster.MetroCluster.MetroCluster.SwitchBackEffectMonitor | DataONTAP.Cluster.MetroCluster.MetroCluster | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: SwitchOver Detection Monitor | The MetroCluster SwitchOver Detection Monitor checks for the occurrence of the MetroCluster switchover event. A switchover is a MetroCluster operation that transfers service from one MetroCluster site to the other site, either as a negotiated switchover that is planned in advance and cleanly shuts down components of the target MetroCluster site or a forced switchover that immediately transfers service. | DataONTAP.Cluster.MetroCluster.MetroCluster.SwitchOverDetectionMonitor | DataONTAP.Cluster.MetroCluster.MetroCluster | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Version Monitor | The MetroCluster Version Monitor checks to ensure that all MetroCluster nodes have the same clustered Data ONTAP version and generates an alert if they do not. | DataONTAP.Cluster.MetroCluster.MetroCluster.VersionMonitor | DataONTAP.Cluster.MetroCluster.MetroCluster | System.Health.ConfigurationState | ConfigurationHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Aggregate Redundancy Monitor | The MetroCluster Aggregate Redundancy Monitor checks the rules for the aggregate disk pool allocation. | DataONTAP.Cluster.MetroCluster.Node.Aggregate.AggregateRedundancyMonitor | DataONTAP.Cluster.MetroCluster.Node.Aggregate | System.Health.ConfigurationState | ConfigurationHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Aggregate Replication Monitor | The MetroCluster Aggregate Replication Monitor checks the aggregate mirror status. | DataONTAP.Cluster.MetroCluster.Node.Aggregate.ReplicationMonitor | DataONTAP.Cluster.MetroCluster.Node.Aggregate | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Node Interconnect Mirror Status Monitor | The MetroCluster Node Interconnect Mirror Status Monitor checks if the interconnect link mirror status is either online or offline. | DataONTAP.Cluster.MetroCluster.Node.Interconnect.MirrorStatusMonitor | DataONTAP.Cluster.MetroCluster.Node.Interconnect | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Node Interconnect Status Monitor | The MetroCluster Node Interconnect Status Monitor checks the status of the interconnect links of the MetroCluster clusters. The monitor state changes to critical if the link is down. | DataONTAP.Cluster.MetroCluster.Node.Interconnect.StatusMonitor | DataONTAP.Cluster.MetroCluster.Node.Interconnect | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: MetroCluster Node Interconnect Adapter Status Monitor | The cluster interconnect adapter enables the cluster nodes in a MetroCluster configuration to communicate with each other and to move data within the cluster. You can monitor the status of the link and verify whether both nodes are running. This monitor checks the state of the physical interconnect adapters. Possible states are the adapter link is up or the link is down. | DataONTAP.Cluster.MetroCluster.Node.InterconnectAdapter.StatusMonitor | DataONTAP.Cluster.MetroCluster.Node.InterconnectAdapter | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Node Interconnect Redundancy Monitor | The MetroCluster Node Interconnect Redundancy Monitor checks the configured number of interconnect connections, including DR and HA connections. In a normal state, the number of redundant connections should be two HA connections and two DR connections. | DataONTAP.Cluster.MetroCluster.Node.InterconnectRedundancyMonitor | DataONTAP.Cluster.MetroCluster.Node | System.Health.ConfigurationState | ConfigurationHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Node Object Limit Monitor | The MetroCluster Node Object Limit Monitor verifies the state of the node object limit option in clustered Data ONTAP. | DataONTAP.Cluster.MetroCluster.Node.ObjectLimitMonitor | DataONTAP.Cluster.MetroCluster.Node | System.Health.ConfigurationState | ConfigurationHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Node Root Volume Configuration Monitor | The MetroCluster Node Root Volume Configuration Monitor checks whether the root volume is the only volume using RAID with Syncmirror for a mirrored aggregate, otherwise the monitor status will change to critical. | DataONTAP.Cluster.MetroCluster.Node.RootVolumeConfigurationMonitor | DataONTAP.Cluster.MetroCluster.Node | System.Health.ConfigurationState | ConfigurationHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.2SingleEventLog2StateMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Storage Bridge Status Monitor | In a MetroCluster configuration, a storage bridge connects the SAS disk shelves that connect to the FC-to-SAS bridges. The name of the bridge identifies the controller that the bridge connects to and the port used for the connection. This monitor checks if the MetroCluster Storage Bridge status is OK, bridge temperature status is normal, bridge SAS ports are enabled and online, and bridge FC ports are enabled and online. | DataONTAP.Cluster.MetroCluster.StorageBridge.StatusMonitor | DataONTAP.Cluster.MetroCluster.StorageBridge | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.3SingleEventLog3StateUnitMonitorType | True | Public | |
| Clustered Data ONTAP MetroCluster: Storage Virtual Machine DR Replication Monitor | The MetroCluster Storage Virtual Machine DR Replication Monitor checks the state of the Storage Virtual Machine replication. | DataONTAP.Cluster.MetroCluster.StorageVirtualMachine.ReplicationConfigurationStatusMonitor | DataONTAP.Cluster.MetroCluster.StorageVirtualMachine | System.Health.ConfigurationState | ConfigurationHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | Microsoft.Windows.3SingleEventLog3StateUnitMonitorType | True | Public | |