 DisplayNameDescriptionIDTargetParent MonitorCategoryEnabledInstance NameCounter NameFrequencyAlert GenerateAlert SeverityAlert PriorityAlert Auto ResolveMonitor TypeRemotableAccessibilityRunAs
IBM.FlexSystem.AmbientTempOutAlert monitor for IBM FlexSystem Chassis ambient temperature over Alert monitor for IBM FlexSystem Chassis ambient temperature out of range IBM.FlexSystem.AmbientTempOutIBM.FlexSystem.ChassisSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.BladeInstalledOrRemovedAlert monitor for IBM Flex System Chassis Node installation or removal Alert monitor for IBM Flex System Chassis Node installation or removal IBM.FlexSystem.BladeInstalledOrRemovedIBM.FlexSystem.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.2StateMonitorTypeForEventPairTruePublic
IBM.FlexSystem.BladeIO.IncompatibleAlert monitor for IBM Flex System Chassis Node incompatible with I/O module(s) Alert monitor for IBM Flex System Chassis Node incompatible with I/O module(s) IBM.FlexSystem.BladeIO.IncompatibleIBM.FlexSystem.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.BladeMgmtCommunication.FailedAlert monitor for IBM Flex System Chassis Node mgmt communication failures Alert monitor for IBM Flex System Chassis Node mgmt communication failures IBM.FlexSystem.BladeMgmtCommunication.FailedIBM.FlexSystem.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.BladeOpenFabricManager.IncompatibleAlert monitor for IBM Flex System Chassis Node Open Fabric Manager incompatibilities Alert monitor for IBM Flex System Chassis Node Open Fabric Manager incompatibilities IBM.FlexSystem.BladeOpenFabricManager.IncompatibleIBM.FlexSystem.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.FlexSystem.BladePowerBudget.DeniedAlert monitor for IBM Flex System Chassis Node power denied due to power budget Alert monitor for IBM Flex System Chassis Node power denied due to power budget IBM.FlexSystem.BladePowerBudget.DeniedIBM.FlexSystem.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.BladePowerOn.InsufficientAlert monitor for IBM Flex System Chassis Node insufficient-power-to-power-on conditions Alert monitor for IBM Flex System Chassis Node insufficient-power-to-power-on conditions IBM.FlexSystem.BladePowerOn.InsufficientIBM.FlexSystem.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.CallHome.FailedAlert monitor for IBM Flex System Chassis call home operation failures Alert monitor for IBM Flex System Chassis call home operation failures IBM.FlexSystem.CallHome.FailedIBM.FlexSystem.ChassisSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetMonitorTypeForChassisTruePublic
IBM.FlexSystem.ChassisAmbientOverTemperature.FailedAlert monitor for IBM Flex System Chassis chassis ambient over-temperature conditions Alert monitor for IBM Flex System Chassis chassis ambient over-temperature conditions IBM.FlexSystem.ChassisAmbientOverTemperature.FailedIBM.FlexSystem.ChassisSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetMonitorTypeForChassisTruePublic
IBM.FlexSystem.ChassisTempDeviceUnavailableAlert monitor for IBM FlexSystem Chassis temperature device unavailable Alert monitor for IBM FlexSystem Chassis temperature device unavailable IBM.FlexSystem.ChassisTempDeviceUnavailableIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.ChassisVPDInvalidAlert monitor for IBM FlexSystem Chassis VPD invalid Alert monitor for IBM FlexSystem Chassis VPD invalid IBM.FlexSystem.ChassisVPDInvalidIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.ChassisVPDUnavailableAlert monitor for IBM FlexSystem Chassis VPD unavailable Alert monitor for IBM FlexSystem Chassis VPD invalid IBM.FlexSystem.ChassisVPDUnavailableIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.CMMBatteryLowAlert monitor for IBM FlexSystem CMM Battery low Alert monitor for IBM FlexSystem CMM Battery low IBM.FlexSystem.CMMBatteryLowIBM.FlexSystem.ManagementModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.CMMBayUndetectedAlert monitor for IBM FlexSystem CMM bay undetected Alert monitor for IBM FlexSystem CMM bay undetected IBM.FlexSystem.CMMBayUndetectedIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.CMMCommUnavailableAlert monitor for IBM FlexSystem CMM communication unavailable Alert monitor for IBM FlexSystem CMM communication unavailable IBM.FlexSystem.CMMCommUnavailableIBM.FlexSystem.ManagementModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.FlexSystem.CMMUnconnectedAlert monitor for IBM FlexSystem CMM unconnected Alert monitor for IBM FlexSystem CMM unconnected IBM.FlexSystem.CMMUnconnectedIBM.FlexSystem.ManagementModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.CMMVPDInvalidAlert monitor for IBM FlexSystem CMM VPD invalid Alert monitor for IBM FlexSystem CMM VPD invalid IBM.FlexSystem.CMMVPDInvalidIBM.FlexSystem.ManagementModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.CMMVPDUnavailableAlert monitor for IBM FlexSystem CMM VPD unavailable Alert monitor for IBM FlexSystem CMM VPD unavailable IBM.FlexSystem.CMMVPDUnavailableIBM.FlexSystem.ManagementModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.CoolingConfInadequateAlert monitor for IBM Flex System cooling configure inadequate Alert monitor for IBM Flex System cooling configure inadequate IBM.FlexSystem.CoolingConfInadequateIBM.FlexSystem.NodeSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.CoolingModule.CriticalFailedAlert monitor for IBM Flex System Chassis fan module critical failures Alert monitor for IBM Flex System Chassis fan module critical failures IBM.FlexSystem.CoolingModule.CriticalFailedIBM.FlexSystem.CoolingModuleSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.CoolingModuleInstalledOrRemovedAlert monitor for IBM Flex System Chassis fan module installation or removal Alert monitor for IBM Flex System Chassis fan module installation or removal IBM.FlexSystem.CoolingModuleInstalledOrRemovedIBM.FlexSystem.CoolingModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.2StateMonitorTypeForEventPairTruePublic
IBM.FlexSystem.CoolingModuleRecommendedSpeed.OutsideAlert monitor for IBM Flex System Chassis fan module degraded conditions Alert monitor for IBM Flex System Chassis fan module degraded conditions IBM.FlexSystem.CoolingModuleRecommendedSpeed.OutsideIBM.FlexSystem.CoolingModuleSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.CoolZoonInadequateAlert monitor for IBM FlexSystem Cooling Zone inadequate cooling Alert monitor for IBM FlexSystem Cooling Zone inadequate cooling IBM.FlexSystem.CoolZoonInadequateIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetMonitorTypeForChassisTruePublic
IBM.FlexSystem.FanCMMUnCommAlert monitor for IBM FlexSystem CMM Fan uncommunicable Alert monitor for IBM FlexSystem CMM Fan uncommunicable IBM.FlexSystem.FanCMMUnCommIBM.FlexSystem.CoolingModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.FanMuxFailedAlert monitor for IBM FlexSystem Fan logical module failed Alert monitor for IBM FlexSystem Fan logical module failed IBM.FlexSystem.FanMuxFailedIBM.FlexSystem.FanMuxModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.FanMuxVPDInvalidAlert monitor for IBM FlexSystem Fan module VPD invalid Alert monitor for IBM FlexSystem Fan module VPD invalid IBM.FlexSystem.FanMuxVPDInvalidIBM.FlexSystem.FanMuxModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.FanMuxVPDUnavailableAlert monitor for IBM FlexSystem Fan logical module VPD unavailable Alert monitor for IBM FlexSystem Fan logical module VPD unavailable IBM.FlexSystem.FanMuxVPDUnavailableIBM.FlexSystem.FanMuxModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.FanVPDInvalidAlert monitor for IBM FlexSystem Fan module VPD invalid Alert monitor for IBM FlexSystem Fan module VPD invalid IBM.FlexSystem.FanVPDInvalidIBM.FlexSystem.CoolingModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.FanVPDUnavailableAlert monitor for IBM FlexSystem Fan module VPD unavailable Alert monitor for IBM FlexSystem Fan module VPD unavailable IBM.FlexSystem.FanVPDUnavailableIBM.FlexSystem.CoolingModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.FrontLEDCardUndetectedAlert monitor for IBM FlexSystem Chassis front LED card undetected Alert monitor for IBM FlexSystem Chassis front LED card undetected IBM.FlexSystem.FrontLEDCardUndetectedIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.HealthStateRegular health checkup monitor for IBM Flex System Chassis Regular health checkup monitor for IBM Flex System Chassis IBM.FlexSystem.HealthStateIBM.FlexSystem.ChassisSystem.Health.PerformanceStateCustomTrue0FalseTrueIBM.FlexSystem.ModulesHealth.MonitorTypeTruePublic
IBM.FlexSystem.HotAirDetectedAlert monitor for IBM FlexSystem hot air detected Alert monitor for IBM FlexSystem hot air detected IBM.FlexSystem.HotAirDetectedIBM.FlexSystem.ChassisSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.IOBlade.IncompatibleAlert monitor for IBM Flex System Chassis I/O module incompatible with blade(s) Alert monitor for IBM Flex System Chassis I/O module incompatible with blade(s) IBM.FlexSystem.IOBlade.IncompatibleIBM.FlexSystem.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOCMMUncommAlert monitor for IBM FlexSystem CMM I/O uncommunicable Alert monitor for IBM FlexSystem CMM I/O uncommunicable IBM.FlexSystem.IOCMMUncommIBM.FlexSystem.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOCommOfflineAlert monitor for IBM FlexSystem I/O module offline Alert monitor for IBM FlexSystem I/O module offline IBM.FlexSystem.IOCommOfflineIBM.FlexSystem.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOCurrent.FailedAlert monitor for IBM Flex System Chassis I/O module current ill conditions Alert monitor for IBM Flex System Chassis I/O module current ill conditions IBM.FlexSystem.IOCurrent.FailedIBM.FlexSystem.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOModule.FailedAlert monitor for IBM Flex System Chassis I/O module faults Alert monitor for IBM Flex System Chassis I/O module faults IBM.FlexSystem.IOModule.FailedIBM.FlexSystem.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOModule.UnrecognizedAlert monitor for IBM Flex System Chassis I/O module unrecognized (hence, not allowed to power on) Alert monitor for IBM Flex System Chassis I/O module unrecognized (hence, not allowed to power on) IBM.FlexSystem.IOModule.UnrecognizedIBM.FlexSystem.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOModuleInstalledOrRemovedAlert monitor for IBM Flex System Chassis I/O module installation or removal Alert monitor for IBM Flex System Chassis I/O module installation or removal IBM.FlexSystem.IOModuleInstalledOrRemovedIBM.FlexSystem.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.2StateMonitorTypeForEventPairTruePublic
IBM.FlexSystem.IOOverTemperature.FailedAlert monitor for IBM Flex System Chassis I/O module over-temperature conditions Alert monitor for IBM Flex System Chassis I/O module over-temperature conditions IBM.FlexSystem.IOOverTemperature.FailedIBM.FlexSystem.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOPOST.FailedAlert monitor for IBM Flex System Chassis I/O module POST failures Alert monitor for IBM Flex System Chassis I/O module POST failures IBM.FlexSystem.IOPOST.FailedIBM.FlexSystem.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOPOST.TimeoutAlert monitor for IBM Flex System Chassis I/O module POST timeout Alert monitor for IBM Flex System Chassis I/O module POST timeout IBM.FlexSystem.IOPOST.TimeoutIBM.FlexSystem.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOPowerOn.InsufficientAlert monitor for IBM Flex System Chassis I/O module insufficient-power-to-power-on condition Alert monitor for IBM Flex System Chassis I/O module insufficient-power-to-power-on condition IBM.FlexSystem.IOPowerOn.InsufficientIBM.FlexSystem.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOUnsupportedAlert monitor for IBM FlexSystem Chassis unsupported I/O Alert monitor for IBM FlexSystem Chassis unsupported I/O IBM.FlexSystem.IOUnsupportedIBM.FlexSystem.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOVPDInvalidAlert monitor for IBM FlexSystem I/O module VPD invalid Alert monitor for IBM FlexSystem I/O module VPD invalid IBM.FlexSystem.IOVPDInvalidIBM.FlexSystem.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.IOVPDRead.FailedAlert monitor for IBM Flex System Chassis I/O module VPD read failures Alert monitor for IBM Flex System Chassis I/O module VPD read failures IBM.FlexSystem.IOVPDRead.FailedIBM.FlexSystem.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.ManagementModuleInstalledOrRemovedAlert monitor for IBM Flex System Chassis management module installation or removal Alert monitor for IBM Flex System Chassis management module installation or removal IBM.FlexSystem.ManagementModuleInstalledOrRemovedIBM.FlexSystem.ManagementModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.2StateMonitorTypeForManagementModuleInsertOrRemoveTruePublic
IBM.FlexSystem.MM.OverTemp.ConditionsAlert monitor for IBM Flex System Chassis MM over-temperature conditions Alert monitor for IBM Flex System Chassis MM over-temperature conditions IBM.FlexSystem.MM.OverTemp.ConditionsIBM.FlexSystem.ChassisSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetMonitorTypeForChassisTruePublic
IBM.FlexSystem.MMBusHungAlert monitor for IBM FlexSystem management bus hung Alert monitor for IBM FlexSystem management bus hung IBM.FlexSystem.MMBusHungIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.MMEventLog.FullAlert monitor for IBM Flex System Chassis MM event log full conditions Alert monitor for IBM Flex System Chassis MM event log full conditions IBM.FlexSystem.MMEventLog.FullIBM.FlexSystem.ChassisSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.MMExternalNetworkConnection.LostAlert monitor for IBM Flex System Chassis MM external network connection lost Alert monitor for IBM Flex System Chassis MM external network connection lost IBM.FlexSystem.MMExternalNetworkConnection.LostIBM.FlexSystem.ManagementModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.MMIPAddress.MismatchAlert monitor for IBM Flex System Chassis MM IP addresses mismatch Alert monitor for IBM Flex System Chassis MM IP addresses mismatch IBM.FlexSystem.MMIPAddress.MismatchIBM.FlexSystem.ChassisSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.Module.HealthStateRegular health checkup monitor for IBM Flex System Chassis module Regular health checkup monitor for IBM Flex System Chassis module IBM.FlexSystem.Module.HealthStateIBM.FlexSystem.ModuleSystem.Health.PerformanceStateCustomTrue0FalseTrueIBM.FlexSystem.ModulesHealth.MonitorTypeTruePublic
IBM.FlexSystem.NodeCommFailedAlert monitor for IBM FlexSystem node communication offline Alert monitor for IBM FlexSystem node communication offline IBM.FlexSystem.NodeCommFailedIBM.FlexSystem.NodeSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.NodeCoolInsuffAlert monitor for IBM FlexSystem node cooling insufficient Alert monitor for IBM FlexSystem node cooling insufficient IBM.FlexSystem.NodeCoolInsuffIBM.FlexSystem.NodeSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.NodeIncompletedInitAlert monitor for IBM FlexSystem node incompleted initialization Alert monitor for IBM FlexSystem node incompleted initialization IBM.FlexSystem.NodeIncompletedInitIBM.FlexSystem.NodeSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.NodeInitialFailedAlert monitor for IBM Flex System Chassis Node initial failed Alert monitor for IBM Flex System Chassis Node initial failed IBM.FlexSystem.NodeInitialFailedIBM.FlexSystem.NodeSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.NodeVPDInvalidAlert monitor for IBM FlexSystem node VPD invalid Alert monitor for IBM FlexSystem node VPD invalid IBM.FlexSystem.NodeVPDInvalidIBM.FlexSystem.NodeSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.OFMOperation.FailedAlert monitor for IBM Flex System Chassis Node Open Fabric Manager operation failures Alert monitor for IBM Flex System Chassis Node Open Fabric Manager operation failures IBM.FlexSystem.OFMOperation.FailedIBM.FlexSystem.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PMMEthernet.Port0FailedAlert monitor for IBM Flex System Chassis primary MM Ethernet port failures Alert monitor for IBM Flex System Chassis primary MM Ethernet port failures IBM.FlexSystem.PMMEthernet.Port0FailedIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.PMMInternalEthernet.LogicalFailedAlert monitor for IBM Flex System Chassis primary MM internal Ethernet switch failures Alert monitor for IBM Flex System Chassis primary MM internal Ethernet switch failures IBM.FlexSystem.PMMInternalEthernet.LogicalFailedIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.PMMInternalIO.ExpanderFailedAlert monitor for IBM Flex System Chassis primary MM internal I/O expander failures Alert monitor for IBM Flex System Chassis primary MM internal I/O expander failures IBM.FlexSystem.PMMInternalIO.ExpanderFailedIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.PMMRealTimeClock.FailedAlert monitor for IBM Flex System Chassis primary MM non-critical subcomponent failures Alert monitor for IBM Flex System Chassis primary MM non-critical subcomponent failures IBM.FlexSystem.PMMRealTimeClock.FailedIBM.FlexSystem.ChassisSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.PowerCommOfflineAlert monitor for IBM FlexSystem Power module communication unavailable Alert monitor for IBM FlexSystem Power module communication unavailable IBM.FlexSystem.PowerCommOfflineIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerFanFailureAlert monitor for IBM FlexSystem Power supply fan failure Alert monitor for IBM FlexSystem Power supply fan failure IBM.FlexSystem.PowerFanFailureIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerFanLowAlert monitor for IBM FlexSystem Power supply fan speed outside range Alert monitor for IBM FlexSystem Power supply fan speed outside range IBM.FlexSystem.PowerFanLowIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerMeterOfflineAlert monitor for IBM FlexSystem Power meter offline Alert monitor for IBM FlexSystem Power meter offline IBM.FlexSystem.PowerMeterOfflineIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerModuleAC.FailedAlert monitor for IBM Flex System Chassis power module AC faults Alert monitor for IBM Flex System Chassis power module AC faults IBM.FlexSystem.PowerModuleAC.FailedIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerModuleCommunication.FailedAlert monitor for IBM Flex System Chassis power module current share mismatches Alert monitor for IBM Flex System Chassis power module current share mismatches IBM.FlexSystem.PowerModuleCommunication.FailedIBM.FlexSystem.PowerModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerModuleDC.FailedAlert monitor for IBM Flex System Chassis power module DC faults Alert monitor for IBM Flex System Chassis power module DC faults IBM.FlexSystem.PowerModuleDC.FailedIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerModuleInstalledOrRemovedAlert monitor for IBM Flex System Chassis power module installation or removal Alert monitor for IBM Flex System Chassis power module installation or removal IBM.FlexSystem.PowerModuleInstalledOrRemovedIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.2StateMonitorTypeForEventPairTruePublic
IBM.FlexSystem.PowerModuleTemperature.FailedAlert monitor for IBM Flex System Chassis power module temperature ill conditions Alert monitor for IBM Flex System Chassis power module temperature ill conditions IBM.FlexSystem.PowerModuleTemperature.FailedIBM.FlexSystem.PowerModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerModuleVoltage.FailedAlert monitor for IBM Flex System Chassis power module voltage ill conditions Alert monitor for IBM Flex System Chassis power module voltage ill conditions IBM.FlexSystem.PowerModuleVoltage.FailedIBM.FlexSystem.PowerModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerOverCurrentAlert monitor for IBM FlexSystem Power overcurrent Alert monitor for IBM FlexSystem Power overcurrent IBM.FlexSystem.PowerOverCurrentIBM.FlexSystem.PowerModuleSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerOverVoltageAlert monitor for IBM FlexSystem Power overvoltage Alert monitor for IBM FlexSystem Power overvoltage IBM.FlexSystem.PowerOverVoltageIBM.FlexSystem.PowerModuleSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerShutDownAlert monitor for IBM FlexSystem Power supply shut down due to overcurrent Alert monitor for IBM FlexSystem Power supply shut down due to overcurrent IBM.FlexSystem.PowerShutDownIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerUnderVoltageAlert monitor for IBM FlexSystem Power undervoltage Alert monitor for IBM FlexSystem Power undervoltage IBM.FlexSystem.PowerUnderVoltageIBM.FlexSystem.PowerModuleSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerUnidentifiedHW.DeniedAlert monitor for IBM Flex System Chassis Node power denied due to unidentified hardware Alert monitor for IBM Flex System Chassis Node power denied due to unidentified hardware IBM.FlexSystem.PowerUnidentifiedHW.DeniedIBM.FlexSystem.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.PowerVPDInvalidAlert monitor for IBM FlexSystem Power modul VPD invalid Alert monitor for IBM FlexSystem Power modul VPD invalid IBM.FlexSystem.PowerVPDInvalidIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.ProxyComputer.MPVersion.HealthCheckRegular health checkup monitor for IBM management packs compatibility Regular health checkup monitor for IBM management packs compatibility IBM.FlexSystem.ProxyComputer.MPVersion.HealthCheckIBM.FlexSystem.ProxyComputerSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.ProxyComputer.MPVersion.MonitorTypeTruePublic
IBM.FlexSystem.RearLEDCardUndetectedAlert monitor for IBM FlexSystem Chassis rear LED card undetected Alert monitor for IBM FlexSystem Chassis rear LED card undetected IBM.FlexSystem.RearLEDCardUndetectedIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.ResetWatchdog.TimeoutAlert monitor for IBM FlexSystem Chassis reset watchdog timeout Alert monitor for IBM FlexSystem Chassis reset watchdog timeout IBM.FlexSystem.ResetWatchdog.TimeoutIBM.FlexSystem.ChassisSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.SecurityPolicyPendingAlert monitor for IBM FlexSystem Security Policy pending Alert monitor for IBM FlexSystem Security Policy pending IBM.FlexSystem.SecurityPolicyPendingIBM.FlexSystem.NodeSystem.Health.SecurityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.SecurityServiceAlert monitor for IBM FlexSystem Chassis security service exception Alert monitor for IBM FlexSystem Chassis security service exception IBM.FlexSystem.SecurityServiceIBM.FlexSystem.ChassisSystem.Health.SecurityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.SecurityServiceExceptionAlert monitor for IBM FlexSystem Security Service exception Alert monitor for IBM FlexSystem Security Service exception IBM.FlexSystem.SecurityServiceExceptionIBM.FlexSystem.NodeSystem.Health.SecurityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.SecurityServiceInExceptionAlert monitor for IBM FlexSystem Security Service internal exception Alert monitor for IBM FlexSystem Security Service internal exception IBM.FlexSystem.SecurityServiceInExceptionIBM.FlexSystem.NodeSystem.Health.SecurityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.FlexSystem.SMMSMBus.FailedAlert monitor for IBM Flex System Chassis standby MM SMBus failures Alert monitor for IBM Flex System Chassis standby MM SMBus failures IBM.FlexSystem.SMMSMBus.FailedIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.SMMSubComponent.FailedAlert monitor for IBM Flex System Chassis standby MM non-critical subcomponent failures Alert monitor for IBM Flex System Chassis standby MM non-critical subcomponent failures IBM.FlexSystem.SMMSubComponent.FailedIBM.FlexSystem.ChassisSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetMonitorTypeForChassisTruePublic
IBM.FlexSystem.SMProcessorErrorEventIBM FlexSystem Node system-management processor reported error events IBM FlexSystem Node system-management processor reported error events IBM.FlexSystem.SMProcessorErrorEventIBM.FlexSystem.NodeSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.FlexSystem.SMProcessorWarningEventIBM FlexSystem Node system-management processor reported warning events IBM FlexSystem Node system-management processor reported warning events IBM.FlexSystem.SMProcessorWarningEventIBM.FlexSystem.NodeSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.FlexSystem.SMTPUnreachableAlert monitor for IBM FlexSystem SMTP server unreachable Alert monitor for IBM FlexSystem SMTP server unreachable IBM.FlexSystem.SMTPUnreachableIBM.FlexSystem.ChassisSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.StandbyMMLinkBrokenAlert monitor for IBM FlexSystem standby MM link broken Alert monitor for IBM FlexSystem standby MM link broken IBM.FlexSystem.StandbyMMLinkBrokenIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.StandbyMMLogicalLinkBrokenAlert monitor for IBM FlexSystem standby MM logical link broken Alert monitor for IBM FlexSystem standby MM logical link broken IBM.FlexSystem.StandbyMMLogicalLinkBrokenIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.StandbyMMSyncFailedAlert monitor for IBM FlexSystem Chassis security service exception Alert monitor for IBM FlexSystem Chassis security service exception IBM.FlexSystem.StandbyMMSyncFailedIBM.FlexSystem.ChassisSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.FlexSystem.UnclassifiedHW.FailedAlert monitor for IBM Flex System Chassis unclassified hardware failures Alert monitor for IBM Flex System Chassis unclassified hardware failures IBM.FlexSystem.UnclassifiedHW.FailedIBM.FlexSystem.ChassisSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateManualResetSpecialEventMonitorTypeForChassisTruePublic
IBM.FlexSystem.PowerVPDUnavailableIBM.FlexSystem.PowerVPDUnavailableIBM.FlexSystem.PowerVPDUnavailableIBM.FlexSystem.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModuleTruePublic