All Unit Monitors in Lenovo.HardwareMgmtPack.BladeCenter Management Pack

 DisplayNameDescriptionIDTargetParent MonitorCategoryEnabledInstance NameCounter NameFrequencyAlert GenerateAlert SeverityAlert PriorityAlert Auto ResolveMonitor TypeRemotableAccessibilityRunAs
IBM.BladeCenter.AutoFTPConfig.ErrorAlert monitor for Lenovo BladeCenter automated FTP failures Alert monitor for Lenovo BladeCenter automated FTP failures IBM.BladeCenter.AutoFTPConfig.ErrorIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.Blade.IsolatedAlert monitor for Lenovo BladeCenter blades isolated events Alert monitor for Lenovo BladeCenter blades isolated events IBM.BladeCenter.Blade.IsolatedIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.Blade.ThrottledAlert monitor for Lenovo BladeCenter blade throttling events Alert monitor for Lenovo BladeCenter blade throttling events IBM.BladeCenter.Blade.ThrottledIBM.BladeCenter.BladeModuleSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeAddinCard.UnconnectedAlert monitor for Lenovo BladeCenter blade add-in card connection conditions Alert monitor for Lenovo BladeCenter blade add-in card connection conditions IBM.BladeCenter.BladeAddinCard.UnconnectedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeChassis.CompatibleWarningAlert monitor for Lenovo BladeCenter blade incompatible with chassis Alert monitor for Lenovo BladeCenter blade incompatible with chassis IBM.BladeCenter.BladeChassis.CompatibleWarningIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeClockBattery.FailedAlert monitor for Lenovo BladeCenter blade clock battery ill conditions Alert monitor for Lenovo BladeCenter blade clock battery ill conditions IBM.BladeCenter.BladeClockBattery.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeCPU.FailedAlert monitor for Lenovo BladeCenter blade CPU critical errors Alert monitor for Lenovo BladeCenter blade CPU critical errors IBM.BladeCenter.BladeCPU.FailedIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeCPUTemperature.FailedAlert monitor for Lenovo BladeCenter blade CPU over-temperature conditions Alert monitor for Lenovo BladeCenter blade CPU over-temperature conditions IBM.BladeCenter.BladeCPUTemperature.FailedIBM.BladeCenter.BladeModuleSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeDIMM.FailedAlert monitor for Lenovo BladeCenter blade DIMM critical errors Alert monitor for Lenovo BladeCenter blade DIMM critical errors IBM.BladeCenter.BladeDIMM.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeExpansionModule.FailedAlert monitor for Lenovo BladeCenter blade expansion module failures Alert monitor for Lenovo BladeCenter blade expansion module failures IBM.BladeCenter.BladeExpansionModule.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeFirmware.CorruptAlert monitor for Lenovo BladeCenter blade firmware corruption Alert monitor for Lenovo BladeCenter blade firmware corruption IBM.BladeCenter.BladeFirmware.CorruptIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeHSEC.FailedAlert monitor for Lenovo BladeCenter blade high-speed expansion card faults Alert monitor for Lenovo BladeCenter blade high-speed expansion card faults IBM.BladeCenter.BladeHSEC.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeInstalledOrRemovedAlert monitor for Lenovo BladeCenter blade installation or removal Alert monitor for Lenovo BladeCenter blade installation or removal IBM.BladeCenter.BladeInstalledOrRemovedIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.2StateMonitorTypeForEventPairTruePublic
IBM.BladeCenter.BladeIO.IncompatibleAlert monitor for Lenovo BladeCenter blade incompatible with I/O module(s) Alert monitor for Lenovo BladeCenter blade incompatible with I/O module(s) IBM.BladeCenter.BladeIO.IncompatibleIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeIOBoard.FailedAlert monitor for Lenovo BladeCenter blade I/O board failures Alert monitor for Lenovo BladeCenter blade I/O board failures IBM.BladeCenter.BladeIOBoard.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeIOGraphicsAdapter.FailedAlert monitor for Lenovo BladeCenter blade I/O-graphics-adapter failures Alert monitor for Lenovo BladeCenter blade I/O-graphics-adapter failures IBM.BladeCenter.BladeIOGraphicsAdapter.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeLocalHardDrive.FailedAlert monitor for Lenovo BladeCenter blade local hard drive failures Alert monitor for Lenovo BladeCenter blade local hard drive failures IBM.BladeCenter.BladeLocalHardDrive.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeMemory.UncorrectableAlert monitor for Lenovo BladeCenter blade uncorrectable memory or system bus error Alert monitor for Lenovo BladeCenter blade uncorrectable memory or system bus error IBM.BladeCenter.BladeMemory.UncorrectableIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeMgmtCommunication.FailedAlert monitor for Lenovo BladeCenter blade mgmt communication failures Alert monitor for Lenovo BladeCenter blade mgmt communication failures IBM.BladeCenter.BladeMgmtCommunication.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeOpenFabricManager.IncompatibleAlert monitor for Lenovo BladeCenter blade Open Fabric Manager incompatibilities Alert monitor for Lenovo BladeCenter blade Open Fabric Manager incompatibilities IBM.BladeCenter.BladeOpenFabricManager.IncompatibleIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeOS.HungAlert monitor for Lenovo BladeCenter blade OS hung failures Alert monitor for Lenovo BladeCenter blade OS hung failures IBM.BladeCenter.BladeOS.HungIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePCI.FailedAlert monitor for Lenovo BladeCenter blade PCI failures Alert monitor for Lenovo BladeCenter blade PCI failures IBM.BladeCenter.BladePCI.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePOST.FailedAlert monitor for Lenovo BladeCenter blade POST failures Alert monitor for Lenovo BladeCenter blade POST failures IBM.BladeCenter.BladePOST.FailedIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePower.Failed28000Alert monitor for Lenovo BladeCenter blade power faults (condition 00028000) Alert monitor for Lenovo BladeCenter blade power faults (condition 00028000) IBM.BladeCenter.BladePower.Failed28000IBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePower.Failed28001Alert monitor for Lenovo BladeCenter blade power faults (condition 00028001) Alert monitor for Lenovo BladeCenter blade power faults (condition 00028001) IBM.BladeCenter.BladePower.Failed28001IBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePowerBudget.DeniedAlert monitor for Lenovo BladeCenter blade power denied due to power budget Alert monitor for Lenovo BladeCenter blade power denied due to power budget IBM.BladeCenter.BladePowerBudget.DeniedIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePowerController.FailedAlert monitor for Lenovo BladeCenter blade power controller failures Alert monitor for Lenovo BladeCenter blade power controller failures IBM.BladeCenter.BladePowerController.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePowerJumper.MissedAlert monitor for Lenovo BladeCenter blade power jumper missing Alert monitor for Lenovo BladeCenter blade power jumper missing IBM.BladeCenter.BladePowerJumper.MissedIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePowerOff.DueToCoolingAlert monitor for Lenovo BladeCenter blade powered off due to cooling failures Alert monitor for Lenovo BladeCenter blade powered off due to cooling failures IBM.BladeCenter.BladePowerOff.DueToCoolingIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePowerOff.DueToTemperatureAlert monitor for Lenovo BladeCenter blade powered off due to temperature conditions Alert monitor for Lenovo BladeCenter blade powered off due to temperature conditions IBM.BladeCenter.BladePowerOff.DueToTemperatureIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladePowerOn.InsufficientAlert monitor for Lenovo BladeCenter blade insufficient-power-to-power-on conditions Alert monitor for Lenovo BladeCenter blade insufficient-power-to-power-on conditions IBM.BladeCenter.BladePowerOn.InsufficientIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeStorageECard.UnsupportedAlert monitor for Lenovo BladeCenter blade storage expansion card not supported Alert monitor for Lenovo BladeCenter blade storage expansion card not supported IBM.BladeCenter.BladeStorageECard.UnsupportedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeSubcomponentConfig.FailedAlert monitor for Lenovo BladeCenter blade subcomponent configuration failures Alert monitor for Lenovo BladeCenter blade subcomponent configuration failures IBM.BladeCenter.BladeSubcomponentConfig.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeSystemBoard.FailedAlert monitor for Lenovo BladeCenter blade system board failures Alert monitor for Lenovo BladeCenter blade system board failures IBM.BladeCenter.BladeSystemBoard.FailedIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeSystemBoot.FailedAlert monitor for Lenovo BladeCenter blade system boot failures Alert monitor for Lenovo BladeCenter blade system boot failures IBM.BladeCenter.BladeSystemBoot.FailedIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.BladeVoltage.FailedAlert monitor for Lenovo BladeCenter blade voltage ill conditions Alert monitor for Lenovo BladeCenter blade voltage ill conditions IBM.BladeCenter.BladeVoltage.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.CallHome.FailedAlert monitor for Lenovo BladeCenter call home operation failures Alert monitor for Lenovo BladeCenter call home operation failures IBM.BladeCenter.CallHome.FailedIBM.BladeCenterSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.CFCard.InoperableAlert monitor for Lenovo BladeCenter compact flash card failures Alert monitor for Lenovo BladeCenter compact flash card failures IBM.BladeCenter.CFCard.InoperableIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.ChassisAirFilter.FailedAlert monitor for Lenovo BladeCenter chassis air filter ill conditions Alert monitor for Lenovo BladeCenter chassis air filter ill conditions IBM.BladeCenter.ChassisAirFilter.FailedIBM.BladeCenter.ChassisSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForChassisTruePublic
IBM.BladeCenter.ChassisAlarmPanel.FailedAlert monitor for Lenovo BladeCenter chassis alarm panel hardware Alert monitor for Lenovo BladeCenter chassis alarm panel hardware IBM.BladeCenter.ChassisAlarmPanel.FailedIBM.BladeCenter.ChassisSystem.Health.SecurityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForChassisTruePublic
IBM.BladeCenter.ChassisAmbientOverTemperature.FailedAlert monitor for Lenovo BladeCenter chassis ambient over-temperature conditions Alert monitor for Lenovo BladeCenter chassis ambient over-temperature conditions IBM.BladeCenter.ChassisAmbientOverTemperature.FailedIBM.BladeCenter.ChassisSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForChassisTruePublic
IBM.BladeCenter.ChassisAmbientUnderTemperature.FailedAlert monitor for Lenovo BladeCenter chassis ambient under-temperature conditions Alert monitor for Lenovo BladeCenter chassis ambient under-temperature conditions IBM.BladeCenter.ChassisAmbientUnderTemperature.FailedIBM.BladeCenter.ChassisSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForChassisTruePublic
IBM.BladeCenter.ChassisCooling.InsufficientAlert monitor for Lenovo BladeCenter chassis cooling critical conditions Alert monitor for Lenovo BladeCenter chassis cooling critical conditions IBM.BladeCenter.ChassisCooling.InsufficientIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.ChassisCooling.ReducedAlert monitor for Lenovo BladeCenter chassis cooling degraded condition Alert monitor for Lenovo BladeCenter chassis cooling degraded condition IBM.BladeCenter.ChassisCooling.ReducedIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.CoolingModule.CriticalFailedAlert monitor for Lenovo BladeCenter cooling module critical failures Alert monitor for Lenovo BladeCenter cooling module critical failures IBM.BladeCenter.CoolingModule.CriticalFailedIBM.BladeCenter.CoolingModuleSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.CoolingModule.MismatchAlert monitor for Lenovo BladeCenter cooling modules mismatch Alert monitor for Lenovo BladeCenter cooling modules mismatch IBM.BladeCenter.CoolingModule.MismatchIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.CoolingModule.UnrecognizedAlert monitor for Lenovo BladeCenter cooling module unrecognized Alert monitor for Lenovo BladeCenter cooling module unrecognized IBM.BladeCenter.CoolingModule.UnrecognizedIBM.BladeCenter.CoolingModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.CoolingModuleCommunication.FailedAlert monitor for Lenovo BladeCenter cooling module communication failures Alert monitor for Lenovo BladeCenter cooling module communication failures IBM.BladeCenter.CoolingModuleCommunication.FailedIBM.BladeCenter.CoolingModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.CoolingModuleInstalledOrRemovedAlert monitor for Lenovo BladeCenter cooling module installation or removal Alert monitor for Lenovo BladeCenter cooling module installation or removal IBM.BladeCenter.CoolingModuleInstalledOrRemovedIBM.BladeCenter.CoolingModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.2StateMonitorTypeForEventPairTruePublic
IBM.BladeCenter.CoolingModuleRecommendedSpeed.OutsideAlert monitor for Lenovo BladeCenter cooling module degraded conditions Alert monitor for Lenovo BladeCenter cooling module degraded conditions IBM.BladeCenter.CoolingModuleRecommendedSpeed.OutsideIBM.BladeCenter.CoolingModuleSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.HealthStateRegular health checkup monitor for Lenovo BladeCenter Regular health checkup monitor for Lenovo BladeCenter IBM.BladeCenter.HealthStateIBM.BladeCenterSystem.Health.PerformanceStateCustomTrue0FalseTrueIBM.BladeCenter.ModulesHealth.MonitorTypeTruePublic
IBM.BladeCenter.IOBlade.IncompatibleAlert monitor for Lenovo BladeCenter I/O module incompatible with blade(s) Alert monitor for Lenovo BladeCenter I/O module incompatible with blade(s) IBM.BladeCenter.IOBlade.IncompatibleIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOConfigChange.FailedAlert monitor for Lenovo BladeCenter I/O module configuration change failures Alert monitor for Lenovo BladeCenter I/O module configuration change failures IBM.BladeCenter.IOConfigChange.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOCurrent.FailedAlert monitor for Lenovo BladeCenter I/O module current ill conditions Alert monitor for Lenovo BladeCenter I/O module current ill conditions IBM.BladeCenter.IOCurrent.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IODiskDrivePFA.FailedAlert monitor for Lenovo BladeCenter I/O module disk drive PFA conditions Alert monitor for Lenovo BladeCenter I/O module disk drive PFA conditions IBM.BladeCenter.IODiskDrivePFA.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOMgmtCommunication.FailedAlert monitor for Lenovo BladeCenter I/O module mgmt communication failures Alert monitor for Lenovo BladeCenter I/O module mgmt communication failures IBM.BladeCenter.IOMgmtCommunication.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOModule.FailedAlert monitor for Lenovo BladeCenter I/O module faults Alert monitor for Lenovo BladeCenter I/O module faults IBM.BladeCenter.IOModule.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOModule.UnrecognizedAlert monitor for Lenovo BladeCenter I/O module unrecognized (hence, not allowed to power on) Alert monitor for Lenovo BladeCenter I/O module unrecognized (hence, not allowed to power on) IBM.BladeCenter.IOModule.UnrecognizedIBM.BladeCenter.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOModule.UnsupportedAlert monitor for Lenovo BladeCenter I/O module interposer not supported Alert monitor for Lenovo BladeCenter I/O module interposer not supported IBM.BladeCenter.IOModule.UnsupportedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOModuleInstalledOrRemovedAlert monitor for Lenovo BladeCenter I/O module installation or removal Alert monitor for Lenovo BladeCenter I/O module installation or removal IBM.BladeCenter.IOModuleInstalledOrRemovedIBM.BladeCenter.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.2StateMonitorTypeForEventPairTruePublic
IBM.BladeCenter.IOModules.IncompatibleAlert monitor for Lenovo BladeCenter I/O module incompatible with other I/O-module(s) Alert monitor for Lenovo BladeCenter I/O module incompatible with other I/O-module(s) IBM.BladeCenter.IOModules.IncompatibleIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOModules.MismatchAlert monitor for Lenovo BladeCenter SAS I/O modules mismatch Alert monitor for Lenovo BladeCenter SAS I/O modules mismatch IBM.BladeCenter.IOModules.MismatchIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOOverTemperature.FailedAlert monitor for Lenovo BladeCenter I/O module over-temperature conditions Alert monitor for Lenovo BladeCenter I/O module over-temperature conditions IBM.BladeCenter.IOOverTemperature.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOPOST.FailedAlert monitor for Lenovo BladeCenter I/O module POST failures Alert monitor for Lenovo BladeCenter I/O module POST failures IBM.BladeCenter.IOPOST.FailedIBM.BladeCenter.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOPOST.TimeoutAlert monitor for Lenovo BladeCenter I/O module POST timeout Alert monitor for Lenovo BladeCenter I/O module POST timeout IBM.BladeCenter.IOPOST.TimeoutIBM.BladeCenter.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOPowerOn.InsufficientAlert monitor for Lenovo BladeCenter I/O module insufficient-power-to-power-on condition Alert monitor for Lenovo BladeCenter I/O module insufficient-power-to-power-on condition IBM.BladeCenter.IOPowerOn.InsufficientIBM.BladeCenter.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOPowerRedundancy.LostAlert monitor for Lenovo BladeCenter I/O module power redundancy lost Alert monitor for Lenovo BladeCenter I/O module power redundancy lost IBM.BladeCenter.IOPowerRedundancy.LostIBM.BladeCenter.IOModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IORAIDSASSwitchBattery.FailedAlert monitor for Lenovo BladeCenter RAID SAS Switch battery ill conditions Alert monitor for Lenovo BladeCenter RAID SAS Switch battery ill conditions IBM.BladeCenter.IORAIDSASSwitchBattery.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IORAIDSASSwitchBattery.MissedAlert monitor for Lenovo BladeCenter RAID SAS Switch battery missing Alert monitor for Lenovo BladeCenter RAID SAS Switch battery missing IBM.BladeCenter.IORAIDSASSwitchBattery.MissedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IORAIDSASSwitchDriveArray.FailedAlert monitor for Lenovo BladeCenter RAID SAS Switch drive array configuration errors Alert monitor for Lenovo BladeCenter RAID SAS Switch drive array configuration errors IBM.BladeCenter.IORAIDSASSwitchDriveArray.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IORAIDSASSwitchRAID.WarningAlert monitor for Lenovo BladeCenter RAID SAS Switch RWE (RAID Warning Error) errors Alert monitor for Lenovo BladeCenter RAID SAS Switch RWE (RAID Warning Error) errors IBM.BladeCenter.IORAIDSASSwitchRAID.WarningIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOSASPowerOff.TimeoutAlert monitor for Lenovo BladeCenter SAS I/O module power-off timed-out Alert monitor for Lenovo BladeCenter SAS I/O module power-off timed-out IBM.BladeCenter.IOSASPowerOff.TimeoutIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOStorage.IncompatibleAlert monitor for Lenovo BladeCenter I/O module incompatible with storage modules Alert monitor for Lenovo BladeCenter I/O module incompatible with storage modules IBM.BladeCenter.IOStorage.IncompatibleIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOVPDRead.FailedAlert monitor for Lenovo BladeCenter I/O module VPD read failures Alert monitor for Lenovo BladeCenter I/O module VPD read failures IBM.BladeCenter.IOVPDRead.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOXMLTCPCommunication.FailedAlert monitor for Lenovo BladeCenter SAS I/O module XML TCP communication failures Alert monitor for Lenovo BladeCenter SAS I/O module XML TCP communication failures IBM.BladeCenter.IOXMLTCPCommunication.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.IOZoning.FailedAlert monitor for Lenovo BladeCenter SAS I/O zoning problems Alert monitor for Lenovo BladeCenter SAS I/O zoning problems IBM.BladeCenter.IOZoning.FailedIBM.BladeCenter.IOModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.KVMOwnership.FailedAlert monitor for Lenovo BladeCenter KVM ownership control failures Alert monitor for Lenovo BladeCenter KVM ownership control failures IBM.BladeCenter.KVMOwnership.FailedIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.ManagementModuleInstalledOrRemovedAlert monitor for Lenovo BladeCenter management module installation or removal Alert monitor for Lenovo BladeCenter management module installation or removal IBM.BladeCenter.ManagementModuleInstalledOrRemovedIBM.BladeCenter.ManagementModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.2StateMonitorTypeForManagementModuleInsertOrRemoveTruePublic
IBM.BladeCenter.MediaCard.FailedAlert monitor for Lenovo BladeCenter multiplexer card failures Alert monitor for Lenovo BladeCenter multiplexer card failures IBM.BladeCenter.MediaCard.FailedIBM.BladeCenter.MediaModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForModuleTruePublic
IBM.BladeCenter.MediaModuleInstalledOrRemovedAlert monitor for Lenovo BladeCenter media module installation or removal Alert monitor for Lenovo BladeCenter media module installation or removal IBM.BladeCenter.MediaModuleInstalledOrRemovedIBM.BladeCenter.MediaModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.2StateMonitorTypeForMediaModuleInsertOrRemoveTruePublic
IBM.BladeCenter.MediaTrayHW.FailedAlert monitor for Lenovo BladeCenter media tray hardware failures Alert monitor for Lenovo BladeCenter media tray hardware failures IBM.BladeCenter.MediaTrayHW.FailedIBM.BladeCenter.MediaModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.MediaTrayOwnership.FailedAlert monitor for Lenovo BladeCenter media tray ownership failures Alert monitor for Lenovo BladeCenter media tray ownership failures IBM.BladeCenter.MediaTrayOwnership.FailedIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MediaTrayTemperature.UnavailableAlert monitor for Lenovo BladeCenter media tray temperature unavailable Alert monitor for Lenovo BladeCenter media tray temperature unavailable IBM.BladeCenter.MediaTrayTemperature.UnavailableIBM.BladeCenter.MediaModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.MediaUSBPortOverCurrent.FailedAlert monitor for Lenovo BladeCenter USB port over-current failures Alert monitor for Lenovo BladeCenter USB port over-current failures IBM.BladeCenter.MediaUSBPortOverCurrent.FailedIBM.BladeCenter.MediaModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.MM.IntrusionAlert monitor for Lenovo BladeCenter MM possible intrusions Alert monitor for Lenovo BladeCenter MM possible intrusions IBM.BladeCenter.MM.IntrusionIBM.BladeCenterSystem.Health.SecurityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MM.MismatchAlert monitor for Lenovo BladeCenter MM module mismatch Alert monitor for Lenovo BladeCenter MM module mismatch IBM.BladeCenter.MM.MismatchIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MM.OverTemp.ConditionsAlert monitor for Lenovo BladeCenter MM over-temperature conditions Alert monitor for Lenovo BladeCenter MM over-temperature conditions IBM.BladeCenter.MM.OverTemp.ConditionsIBM.BladeCenterSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MM.UnderTemp.ConditionsAlert monitor for Lenovo BladeCenter MM under-temperature conditions Alert monitor for Lenovo BladeCenter MM under-temperature conditions IBM.BladeCenter.MM.UnderTemp.ConditionsIBM.BladeCenterSystem.Health.PerformanceStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MMEventLog.FullAlert monitor for Lenovo BladeCenter MM event log full conditions Alert monitor for Lenovo BladeCenter MM event log full conditions IBM.BladeCenter.MMEventLog.FullIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MMExternalNetworkConnection.LostAlert monitor for Lenovo BladeCenter MM external network connection lost Alert monitor for Lenovo BladeCenter MM external network connection lost IBM.BladeCenter.MMExternalNetworkConnection.LostIBM.BladeCenter.ManagementModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.MMIPAddress.MismatchAlert monitor for Lenovo BladeCenter MM IP addresses mismatch Alert monitor for Lenovo BladeCenter MM IP addresses mismatch IBM.BladeCenter.MMIPAddress.MismatchIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MMIsolateBus.UnrecoveredAlert monitor for Lenovo BladeCenter MM unable-to-isolate-bus-fault errors Alert monitor for Lenovo BladeCenter MM unable-to-isolate-bus-fault errors IBM.BladeCenter.MMIsolateBus.UnrecoveredIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MMServiceData.CollectionAlert monitor for Lenovo BladeCenter MM service data collection Alert monitor for Lenovo BladeCenter MM service data collection IBM.BladeCenter.MMServiceData.CollectionIBM.BladeCenterSystem.Health.SecurityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MMUserLogin.FailedAlert monitor for Lenovo BladeCenter MM user login failures Alert monitor for Lenovo BladeCenter MM user login failures IBM.BladeCenter.MMUserLogin.FailedIBM.BladeCenterSystem.Health.SecurityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.Module.HealthStateRegular health checkup monitor for Lenovo BladeCenter module Regular health checkup monitor for Lenovo BladeCenter module IBM.BladeCenter.Module.HealthStateIBM.BladeCenter.ModuleSystem.Health.PerformanceStateCustomTrue0FalseTrueIBM.BladeCenter.ModulesHealth.MonitorTypeTruePublic
IBM.BladeCenter.MultiCoolingModule.FailedAlert monitor for Lenovo BladeCenter multiple cooling modules failures Alert monitor for Lenovo BladeCenter multiple cooling modules failures IBM.BladeCenter.MultiCoolingModule.FailedIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.MultiprocessorExpansionBoard.FailedAlert monitor for Lenovo BladeCenter blade multi-processor expansion board failures Alert monitor for Lenovo BladeCenter blade multi-processor expansion board failures IBM.BladeCenter.MultiprocessorExpansionBoard.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.OFMConfig.ClearedAlert monitor for Lenovo BladeCenter Open Fabric Manager configuration cleared Alert monitor for Lenovo BladeCenter Open Fabric Manager configuration cleared IBM.BladeCenter.OFMConfig.ClearedIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.OFMOperation.FailedAlert monitor for Lenovo BladeCenter blade Open Fabric Manager operation failures Alert monitor for Lenovo BladeCenter blade Open Fabric Manager operation failures IBM.BladeCenter.OFMOperation.FailedIBM.BladeCenter.BladeModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.PMMBladeMgmt.Bus1FailedAlert monitor for Lenovo BladeCenter primary MM blade mgmt bus 1 failures Alert monitor for Lenovo BladeCenter primary MM blade mgmt bus 1 failures IBM.BladeCenter.PMMBladeMgmt.Bus1FailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.PMMBladeMgmt.Bus2FailedAlert monitor for Lenovo BladeCenter primary MM blade mgmt bus 2 failures Alert monitor for Lenovo BladeCenter primary MM blade mgmt bus 2 failures IBM.BladeCenter.PMMBladeMgmt.Bus2FailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.PMMEthernet.Port0FailedAlert monitor for Lenovo BladeCenter primary MM Ethernet port 0 failures Alert monitor for Lenovo BladeCenter primary MM Ethernet port 0 failures IBM.BladeCenter.PMMEthernet.Port0FailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.PMMExternalMgmt.BusFailedAlert monitor for Lenovo BladeCenter primary MM external mgmt bus failures Alert monitor for Lenovo BladeCenter primary MM external mgmt bus failures IBM.BladeCenter.PMMExternalMgmt.BusFailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.PMMInternalEthernet.SwitchFailedAlert monitor for Lenovo BladeCenter primary MM internal Ethernet switch failures Alert monitor for Lenovo BladeCenter primary MM internal Ethernet switch failures IBM.BladeCenter.PMMInternalEthernet.SwitchFailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.PMMInternalIO.ExpanderFailedAlert monitor for Lenovo BladeCenter primary MM internal I/O expander failures Alert monitor for Lenovo BladeCenter primary MM internal I/O expander failures IBM.BladeCenter.PMMInternalIO.ExpanderFailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.PMMLocalMgmt.BusFailedAlert monitor for Lenovo BladeCenter primary MM local mgmt bus failures Alert monitor for Lenovo BladeCenter primary MM local mgmt bus failures IBM.BladeCenter.PMMLocalMgmt.BusFailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.PMMNonCriticalSubComponent.FailedAlert monitor for Lenovo BladeCenter primary MM non-critical subcomponent failures Alert monitor for Lenovo BladeCenter primary MM non-critical subcomponent failures IBM.BladeCenter.PMMNonCriticalSubComponent.FailedIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.PowerModule.MismatchAlert monitor for Lenovo BladeCenter power modules mismatch Alert monitor for Lenovo BladeCenter power modules mismatch IBM.BladeCenter.PowerModule.MismatchIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.PowerModuleAC.FailedAlert monitor for Lenovo BladeCenter power module AC faults Alert monitor for Lenovo BladeCenter power module AC faults IBM.BladeCenter.PowerModuleAC.FailedIBM.BladeCenter.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.PowerModuleAC.MismatchAlert monitor for Lenovo BladeCenter power module AC mismatch Alert monitor for Lenovo BladeCenter power module AC mismatch IBM.BladeCenter.PowerModuleAC.MismatchIBM.BladeCenter.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.PowerModuleCommunication.FailedAlert monitor for Lenovo BladeCenter power module current share mismatches Alert monitor for Lenovo BladeCenter power module current share mismatches IBM.BladeCenter.PowerModuleCommunication.FailedIBM.BladeCenter.PowerModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.PowerModuleDC.FailedAlert monitor for Lenovo BladeCenter power module DC faults Alert monitor for Lenovo BladeCenter power module DC faults IBM.BladeCenter.PowerModuleDC.FailedIBM.BladeCenter.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.PowerModuleInstalledOrRemovedAlert monitor for Lenovo BladeCenter power module installation or removal Alert monitor for Lenovo BladeCenter power module installation or removal IBM.BladeCenter.PowerModuleInstalledOrRemovedIBM.BladeCenter.PowerModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.2StateMonitorTypeForEventPairTruePublic
IBM.BladeCenter.PowerModulePSOC.FailedAlert monitor for Lenovo BladeCenter power module PSOC failures Alert monitor for Lenovo BladeCenter power module PSOC failures IBM.BladeCenter.PowerModulePSOC.FailedIBM.BladeCenter.PowerModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.PowerModuleTemperature.FailedAlert monitor for Lenovo BladeCenter power module temperature ill conditions Alert monitor for Lenovo BladeCenter power module temperature ill conditions IBM.BladeCenter.PowerModuleTemperature.FailedIBM.BladeCenter.PowerModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.PowerModuleVoltage.FailedAlert monitor for Lenovo BladeCenter power module voltage ill conditions Alert monitor for Lenovo BladeCenter power module voltage ill conditions IBM.BladeCenter.PowerModuleVoltage.FailedIBM.BladeCenter.PowerModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.PowerOverCurrent.FailedAlert monitor for Lenovo BladeCenter power module current ill conditions Alert monitor for Lenovo BladeCenter power module current ill conditions IBM.BladeCenter.PowerOverCurrent.FailedIBM.BladeCenter.PowerModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.PowerUnidentifiedHW.DeniedAlert monitor for Lenovo BladeCenter blade power denied due to unidentified hardware Alert monitor for Lenovo BladeCenter blade power denied due to unidentified hardware IBM.BladeCenter.PowerUnidentifiedHW.DeniedIBM.BladeCenter.BladeModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.ProxyComputer.MPVersion.HealthCheckRegular health checkup monitor for Lenovo management packs compatibility Regular health checkup monitor for Lenovo management packs compatibility IBM.BladeCenter.ProxyComputer.MPVersion.HealthCheckIBM.BladeCenter.ProxyComputerSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.ProxyComputer.MPVersion.MonitorTypeTruePublic
IBM.BladeCenter.SMBusDevice.FailedAlert monitor for Lenovo BladeCenter MM SMBus device failures Alert monitor for Lenovo BladeCenter MM SMBus device failures IBM.BladeCenter.SMBusDevice.FailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.SMMBladeMgmt.Bus1FailedAlert monitor for Lenovo BladeCenter standby MM blade mgmt bus 1 failures Alert monitor for Lenovo BladeCenter standby MM blade mgmt bus 1 failures IBM.BladeCenter.SMMBladeMgmt.Bus1FailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.SMMBladeMgmt.Bus2FailedAlert monitor for Lenovo BladeCenter standby MM blade mgmt bus 2 failures Alert monitor for Lenovo BladeCenter standby MM blade mgmt bus 2 failures IBM.BladeCenter.SMMBladeMgmt.Bus2FailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.SMMNonCriticalSubComponent.FailedAlert monitor for Lenovo BladeCenter standby MM non-critical subcomponent failures Alert monitor for Lenovo BladeCenter standby MM non-critical subcomponent failures IBM.BladeCenter.SMMNonCriticalSubComponent.FailedIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.SMMSMBus.FailedAlert monitor for Lenovo BladeCenter standby MM SMBus failures Alert monitor for Lenovo BladeCenter standby MM SMBus failures IBM.BladeCenter.SMMSMBus.FailedIBM.BladeCenterSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForBladeCenterTruePublic
IBM.BladeCenter.StorageBatteryBackupUnit.RemovedAlert monitor for Lenovo BladeCenter storage module battery backup unit removed Alert monitor for Lenovo BladeCenter storage module battery backup unit removed IBM.BladeCenter.StorageBatteryBackupUnit.RemovedIBM.BladeCenter.StorageModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.StorageHardDrive.FailedAlert monitor for Lenovo BladeCenter storage module hard drive faults Alert monitor for Lenovo BladeCenter storage module hard drive faults IBM.BladeCenter.StorageHardDrive.FailedIBM.BladeCenter.StorageModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.StorageIO.IncompatibleAlert monitor for Lenovo BladeCenter storage module incompatible with I/O-module(s) Alert monitor for Lenovo BladeCenter storage module incompatible with I/O-module(s) IBM.BladeCenter.StorageIO.IncompatibleIBM.BladeCenter.StorageModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.StorageModule.FailedAlert monitor for Lenovo BladeCenter storage module faults Alert monitor for Lenovo BladeCenter storage module faults IBM.BladeCenter.StorageModule.FailedIBM.BladeCenter.StorageModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.StorageModuleInstalledOrRemovedAlert monitor for Lenovo BladeCenter storage module installation or removal Alert monitor for Lenovo BladeCenter storage module installation or removal IBM.BladeCenter.StorageModuleInstalledOrRemovedIBM.BladeCenter.StorageModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.2StateMonitorTypeForEventPairTruePublic
IBM.BladeCenter.StoragePowerOff.DueToMultiCoolingModuleFailedAlert monitor for Lenovo BladeCenter storage module power-off (due to multiple cooling modules failures) Alert monitor for Lenovo BladeCenter storage module power-off (due to multiple cooling modules failures) IBM.BladeCenter.StoragePowerOff.DueToMultiCoolingModuleFailedIBM.BladeCenter.StorageModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.StoragePowerOff.EventsAlert monitor for Lenovo BladeCenter storage module power-off events Alert monitor for Lenovo BladeCenter storage module power-off events IBM.BladeCenter.StoragePowerOff.EventsIBM.BladeCenter.StorageModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.StoragePowerOn.InsufficientAlert monitor for Lenovo BladeCenter storage insufficient-cooling-to-power-on conditions Alert monitor for Lenovo BladeCenter storage insufficient-cooling-to-power-on conditions IBM.BladeCenter.StoragePowerOn.InsufficientIBM.BladeCenter.StorageModuleSystem.Health.AvailabilityStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.StorageVPDRead.FailedAlert monitor for Lenovo BladeCenter storage module VPD read failures Alert monitor for Lenovo BladeCenter storage module VPD read failures IBM.BladeCenter.StorageVPDRead.FailedIBM.BladeCenter.StorageModuleSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModuleTruePublic
IBM.BladeCenter.UnclassifiedHW.FailedAlert monitor for Lenovo BladeCenter unclassified hardware failures Alert monitor for Lenovo BladeCenter unclassified hardware failures IBM.BladeCenter.UnclassifiedHW.FailedIBM.BladeCenterSystem.Health.ConfigurationStateCustomTrue0TrueMatchMonitorHealthNormalTrueIBM.BladeCenter.SNMPTrap.3StateManualResetSpecialEventMonitorTypeForBladeCenterTruePublic