| DisplayName | Description | ID | Target | Parent Monitor | Category | Enabled | Instance Name | Counter Name | Frequency | Alert Generate | Alert Severity | Alert Priority | Alert Auto Resolve | Monitor Type | Remotable | Accessibility | RunAs |
| Pod Mediator Status | Pod Mediator Status | PureStorage.FlashArray.Monitor.Pod.MediatorStatus | PureStorage.FlashArray.PodReplica | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | PureStorage.FlashArray.Pod.MediatorStatus | True | Internal | |
| PureStorage FlashArray Controller Health Monitor | Monitor for controllers status. | PureStorage.FlashArray.TimedScript.PowerShell.ControllerMonitor | PureStorage.FlashArray.PureController | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | High | True | PureStorage.FlashArray.TimedScript.PowerShell.ControllerMonitor.UnitMonitorType | True | Public | |
| PureStorage FlashArray Connection Health Monitor | PureStorage FlashArray Connection Health Monitor | PureStorage.FlashArray.TimedScript.PowerShell.Monitor | PureStorage.FlashArray.PureArray | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | High | True | PureStorage.FlashArray.TimedScript.PowerShell.Monitor.UnitMonitorType | True | Public | |
| PureStorage FlashArray Port Health Monitor | Monitor for ports status. | PureStorage.FlashArray.TimedScript.PowerShell.PortMonitor | PureStorage.FlashArray.PurePort | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.PortMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Alerts Rule Monitor | Monitor for rules to affect healthy states of arrays | PureStorageFlashArray.AlertsRuleMonitor.Powershell | PureStorage.FlashArray.PureArray | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.AlertsRuleMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray IPS Monitor | The FlashArray IPS (Input Per Second) Monitor calculates the number of bytes written per second, between the controllers and the physical disks, averaged to the last current polled value. This is influenced by the connected hosts that are writing data to the FlashArray and this value is impacted by metadata operations and data reduction features. The last polled value is when the metrics were last polled from the array (usually within 15 minutes). | PureStorageFlashArray.ArrayIPSMonitor.Powershell | PureStorage.FlashArray.PureArray | PureStorageFlashArray.PureArray.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.ArrayPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray OPS Monitor | The FlashArray OPS (Output Per Second) Monitor calculates the number of bytes read per second, between the controllers and the physical disks, averaged to the last current polled value. This is influenced by the connected hosts that are reading data from the FlashArray and this value is impacted by metadata operations and data reduction features. The last polled value is when the metrics were last polled from the array (usually within 15 minutes). | PureStorageFlashArray.ArrayOPSMonitor.Powershell | PureStorage.FlashArray.PureArray | PureStorageFlashArray.PureArray.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.ArrayPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Read Bandwidth Monitor | This is the average number of read requests, in bytes, processed per second by the Array. | PureStorageFlashArray.ArrayReadBandwidthMonitor.Powershell | PureStorage.FlashArray.PureArray | PureStorageFlashArray.PureArray.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.ArrayPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Read Latency Monitor | This is the average time in microseconds (μs) it takes the Array to process a read request. | PureStorageFlashArray.ArrayReadLatencyMonitor.Powershell | PureStorage.FlashArray.PureArray | PureStorageFlashArray.PureArray.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.ArrayPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Space Used Monitor | This is the ratio of FlashArray space currently in use. It is calculated by combining the system space + volumes + snapshots + shared space, and divide that by the total capacity available on the array. The default threshold is 0.8, or 80\%, meaning that an alert will be activated if more than 80\% of the FlashArray is used. | PureStorageFlashArray.ArraySpaceMonitor.Powershell | PureStorage.FlashArray.PureArray | System.Health.AvailabilityState | AvailabilityHealth | True | | | 0 | True | MatchMonitorHealth | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.ArraySpace.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Write Bandwidth Monitor | This is the average number of write requests, in bytes, processed per second by the Array. | PureStorageFlashArray.ArrayWriteBandwidthMonitor.Powershell | PureStorage.FlashArray.PureArray | PureStorageFlashArray.PureArray.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.ArrayPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Write Latency Monitor | This is the average time in microseconds (μs) it takes the Array to process a write request. | PureStorageFlashArray.ArrayWriteLatencyMonitor.Powershell | PureStorage.FlashArray.PureArray | PureStorageFlashArray.PureArray.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.ArrayPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Host IPS Monitor | The Host IPS (Input Per Second) Monitor calculates the number of bytes written per second, between the FlashArray and the Host, averaged to the last current polled value. The last polled value is when the metrics were last polled from the array (usually within 15 minutes). | PureStorageFlashArray.HostIPSMonitor.Powershell | PureStorage.FlashArray.PureHost | PureStorageFlashArray.PureHost.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.HostPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Host OPS Monitor | The Host OPS (Output Per Second) Monitor calculates the number of bytes read per second, between the FlashArray and the Host, averaged to the last current polled value. The last polled value is when the metrics were last polled from the array (usually within 15 minutes). | PureStorageFlashArray.HostOPSMonitor.Powershell | PureStorage.FlashArray.PureHost | PureStorageFlashArray.PureHost.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.HostPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Host Read Bandwidth Monitor | This is the average number of read requests processed per second by the Host. | PureStorageFlashArray.HostReadBandwidthMonitor.Powershell | PureStorage.FlashArray.PureHost | PureStorageFlashArray.PureHost.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.HostPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Host Read Latency Monitor | This is the average time in microseconds (μs) it takes the Host to process a read request. | PureStorageFlashArray.HostReadLatencyMonitor.Powershell | PureStorage.FlashArray.PureHost | PureStorageFlashArray.PureHost.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.HostPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Host Write Bandwidth Monitor | This is the average number of write requests processed per second by the Host. | PureStorageFlashArray.HostWriteBandwidthMonitor.Powershell | PureStorage.FlashArray.PureHost | PureStorageFlashArray.PureHost.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.HostPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Host Write Latency Monitor | This is the average time in microseconds (μs) it takes the Host to process a write request. | PureStorageFlashArray.HostWriteLatencyMonitor.Powershell | PureStorage.FlashArray.PureHost | PureStorageFlashArray.PureHost.AggregateMonitor | PerformanceHealth | True | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.HostPerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Volume IPS Monitor | The Volume IPS (Input Per Second) Monitor calculates the number of bytes written per second, between the FlashArray and the Volume, averaged to the last current polled value. The last polled value is when the metrics were last polled from the array (usually within 15 minutes). | PureStorageFlashArray.VolumeIPSMonitor.Powershell | PureStorage.FlashArray.PureVolume | PureStorageFlashArray.PureVolume.AggregateMonitor | PerformanceHealth | False | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.VolumePerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Volume OPS Monitor | The Volume OPS (Output Per Second) Monitor calculates the number of bytes read per second, between the FlashArray and the Volume, averaged to the last current polled value. The last polled value is when the metrics were last polled from the array (usually within 15 minutes). | PureStorageFlashArray.VolumeOPSMonitor.Powershell | PureStorage.FlashArray.PureVolume | PureStorageFlashArray.PureVolume.AggregateMonitor | PerformanceHealth | False | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.VolumePerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Volume Read Bandwidth Monitor | This is the average number of read requests processed per second by the Volume. | PureStorageFlashArray.VolumeReadBandwidthMonitor.Powershell | PureStorage.FlashArray.PureVolume | PureStorageFlashArray.PureVolume.AggregateMonitor | PerformanceHealth | False | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.VolumePerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Volume Read Latency Monitor | This is the average time in microseconds it takes the Volume to process a read request. | PureStorageFlashArray.VolumeReadLatencyMonitor.Powershell | PureStorage.FlashArray.PureVolume | PureStorageFlashArray.PureVolume.AggregateMonitor | PerformanceHealth | False | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.VolumePerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Volume Write Bandwidth Monitor | This is the average number of write requests processed per second by the Volume. | PureStorageFlashArray.VolumeWriteBandwidthMonitor.Powershell | PureStorage.FlashArray.PureVolume | PureStorageFlashArray.PureVolume.AggregateMonitor | PerformanceHealth | False | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.VolumePerformanceMonitor.UnitMonitorType | True | Public | |
| Pure Storage FlashArray Volume Write Latency Monitor | This is the average time in microseconds (μs) it takes the Volume to process a write request. | PureStorageFlashArray.VolumeWriteLatencyMonitor.Powershell | PureStorage.FlashArray.PureVolume | PureStorageFlashArray.PureVolume.AggregateMonitor | PerformanceHealth | False | | | 0 | True | Warning | Normal | True | PureStorage.FlashArray.TimedScript.PowerShell.VolumePerformanceMonitor.UnitMonitorType | True | Public | |