| DisplayName | ID | Target | Category | Enabled | Alert Generate |
| Sent if a failure (S.M.A.R.T) has been predicted on a hard disk. [HD_MIB_10750] | Fujitsu.Servers.PRIMERGY.Windows.Rules.HD_MIB_10750 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The SNMP agent started but could not communicate with the cluster service. [NTCLUSTER_MIB_10810] | Fujitsu.Servers.PRIMERGY.Windows.Rules.NTCLUSTER_MIB_10810 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The SNMP agent has lost communication with the cluster service. [NTCLUSTER_MIB_10812] | Fujitsu.Servers.PRIMERGY.Windows.Rules.NTCLUSTER_MIB_10812 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A cluster resource group has failed. [NTCLUSTER_MIB_10932] | Fujitsu.Servers.PRIMERGY.Windows.Rules.NTCLUSTER_MIB_10932 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A cluster resource has failed. [NTCLUSTER_MIB_10935] | Fujitsu.Servers.PRIMERGY.Windows.Rules.NTCLUSTER_MIB_10935 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A cluster network is unavailable. [NTCLUSTER_MIB_10938] | Fujitsu.Servers.PRIMERGY.Windows.Rules.NTCLUSTER_MIB_10938 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A cluster network interface has failed. [NTCLUSTER_MIB_10940] | Fujitsu.Servers.PRIMERGY.Windows.Rules.NTCLUSTER_MIB_10940 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A cluster network interface is unreachable. [NTCLUSTER_MIB_10941] | Fujitsu.Servers.PRIMERGY.Windows.Rules.NTCLUSTER_MIB_10941 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A cluster network interface is unavailable. [NTCLUSTER_MIB_10942] | Fujitsu.Servers.PRIMERGY.Windows.Rules.NTCLUSTER_MIB_10942 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A threshold has been exceeded. [THRESHOLD_MIB_12200] | Fujitsu.Servers.PRIMERGY.Windows.Rules.THRESHOLD_MIB_12200 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A threshold has been exceeded. [THRESHOLD_MIB_12201] | Fujitsu.Servers.PRIMERGY.Windows.Rules.THRESHOLD_MIB_12201 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A threshold has been exceeded. [THRESHOLD_MIB_12202] | Fujitsu.Servers.PRIMERGY.Windows.Rules.THRESHOLD_MIB_12202 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | True |
| The communication with management controller failed! [SC2_MIB_12001] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12001 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | True |
| Controller selftest warning. [SC2_MIB_12003] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12003 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | True |
| Controller selftest error. [SC2_MIB_12004] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12004 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition. [SC2_MIB_12005] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12005 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The system was restarted after a severe problem. See server management message log (recovery log) for detailed information. [SC2_MIB_12006] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12006 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The indicated fan or liquid pump became critical [SC2_MIB_12013] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12013 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The indicated fan or liquid pump failed. [SC2_MIB_12014] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12014 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The indicated redundant fan or liquid pump failed [SC2_MIB_12015] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12015 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The temperature of the indicated sensor has reached the warning level. [SC2_MIB_12021] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12021 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled. [SC2_MIB_12022] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12022 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The indicated temperature sensor is broken. [SC2_MIB_12024] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12024 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Power supply status has become critical. [SC2_MIB_12033] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12033 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| One hot-replace power supply failed. [SC2_MIB_12034] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12034 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| One redundant hot-replace power supply failed [SC2_MIB_12035] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12035 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Power supply redundancy no longer available. [SC2_MIB_12036] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12036 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | True |
| Critical temperature in power supply. [SC2_MIB_12037] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12037 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Fan failure prediction in power supply. [SC2_MIB_12038] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12038 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Fan failure in power supply. [SC2_MIB_12039] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12039 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Mains failed in the specified cabinet. This trap can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this trap. [SC2_MIB_12040] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12040 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| DC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs. [SC2_MIB_12041] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12041 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The server is operating on battery power - by UPS or backup battery unit (BBU). [SC2_MIB_12042] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12042 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Power supply voltage is too low. [SC2_MIB_12051] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12051 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Power supply voltage is too high. [SC2_MIB_12052] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12052 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Power supply voltage is out of range. [SC2_MIB_12053] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12053 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Battery is predicted to fail [SC2_MIB_12054] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12054 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| An uncorrectable memory error at specified address was detected. [SC2_MIB_12061] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12061 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| An uncorrectable memory error at specified bank was detected. [SC2_MIB_12063] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12063 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| An uncorrectable memory error at specified module was detected. [SC2_MIB_12065] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12065 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| An uncorrectable memory error at unknown location was detected. [SC2_MIB_12067] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12067 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A memory module is predicted to fail (prefailure). [SC2_MIB_12068] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12068 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A memory module is failing. [SC2_MIB_12069] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12069 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A memory module had failed and was replaced by a hot-spare module. [SC2_MIB_12070] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12070 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Too many correctable memory errors; logging disabled. [SC2_MIB_12071] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12071 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | True |
| Memory errors logging enabled again. [SC2_MIB_12072] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12072 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | True |
| A memory module had failed and was replaced by a hot-spare module. [SC2_MIB_12073] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12073 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A memory error caused loss of memory redundancy [SC2_MIB_12074] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12074 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A CPU is predicted to fail (prefailure). [SC2_MIB_12081] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12081 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A CPU internal error (IERR) occurred [SC2_MIB_12082] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12082 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| A CPU is disabled by BIOS [SC2_MIB_12083] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12083 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| This trap will be sent when a boot retry counter gets zero on power up. [SC2_MIB_12095] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12095 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The System Event Log (message log) is full. No more messages can be logged. This trap will not occur on wrap-around log types [SC2_MIB_12100] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12100 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | True |
| The warning threshold for the number of System Event Log entries has been exceeded. [SC2_MIB_12101] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12101 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | True |
| An error message was written into the systemboard's message log. This could have happened when an error occured before the server management agents were running or any error without a specific trap. See server management message log for detailed error des | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12102 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The front door or housing was opened [SC2_MIB_12110] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12110 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| The front door or housing was opened or closed [SC2_MIB_12112] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12112 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| PCI bus system/parity error [SC2_MIB_12113] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12113 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Customer self service component changed to warning status [SC2_MIB_12120] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12120 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Customer self service component changed to fail status [SC2_MIB_12121] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12121 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | True |
| Customer self service component changed to warning status [SC2_MIB_12122] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12122 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Customer self service component changed to fail status [SC2_MIB_12123] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12123 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Power consumption limit changed to warning status [SC2_MIB_12131] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12131 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |
| Power consumption limit changed to critical status [SC2_MIB_12132] | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12132 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | True |