| DisplayName | ID | Target | Category | Enabled | Alert Generate |
| HPE Agentless IDE Logical Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.ATA_RAID_Logical_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless DC-DC power converter degraded or failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.DC_DC_power_converter_degraded_or_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Drive Array Accelerator data degraded or failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Drive_Array_Accelerator_data_degraded_or_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Drive Array Accelerator degraded, failed or battery failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Drive_Array_Accelerator_degraded_or_failed_or_battery_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Drive Array Controller degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Drive_Array_Controller_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Drive Array Logical Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Drive_Array_Logical_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Drive Array Physical Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Drive_Array_Physical_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Drive Array Spare Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Drive_Array_Spare_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Drive Array Tape Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Drive_Array_Tape_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Drive Array Tape Library door degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Drive_Array_Tape_Library_door_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless External Array Accelerator failed, data failed or battery failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.External_Array_Accelerator_failed_or_data_failed_or_battery_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless External Array Controller degraded or failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.External_Array_Controller_degraded_or_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless External Array Logical Drive failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.External_Array_Logical_Drive_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless External Array Physical Drive failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.External_Array_Physical_Drive_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless External Tape Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.External_Tape_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless External Tape Library degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.External_Tape_Library_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless External Tape Library door degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.External_Tape_Library_door_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Fan degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Fan_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Fan failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Fan_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Fibre Channel Controller degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Fibre_Channel_Controller_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless IDE ATA Disk degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.IDE_ATA_Disk_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Memory Board or Cartridge is failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Memory_Board_Catridge_Failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Memory Board or Cartridge or Riser is removed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Memory_Board_Catridge_Removed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Memory degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Memory_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Memory error tracking disabled. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Memory_error_tracking_disabled.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Network Interface failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Network_Interface_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless NIC Teaming failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.NIC_Teaming_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Power-On-Self-Test degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Power_on_self_test_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Power subsystem degraded or failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Power_sub_system_degraded_or_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Processor degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Processor_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Rack enclosure power subsystem degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Rack_enclosure_power_subsystem_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Rack power subsystem degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Rack_power_subsystem_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Rack power subsystem not redundant. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Rack_power_subsystem_not_redundant.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Rack power supply failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Rack_power_supply_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Rack server power subsystem degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Rack_server_power_subsystem_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Flash Media failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Redundancy_Flash_Media_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Remote Management Processor battery connector degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Remote_Management_Processor_battery_connector_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Remote Management Processor battery failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Remote_Management_Processor_battery_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Remote Management Processor degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Remote_Management_Processor_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Remote Management Processor failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Remote_Management_Processor_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Remote Management Processor keyboard connector degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Remote_Management_Processor_keyboard_connector_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Remote Management Processor mouse connector degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Remote_Management_Processor_mouse_connector_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Remote Management Processor power connector degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Remote_Management_Processor_power_connector_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless SAS/SATA Logical Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.SAS_SATA_Logical_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless SAS/SATA Physical Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.SAS_SATA_Physical_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless SAS Tape Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.SAS_Tape_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless SCSI Physical Drive failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.SCSI_Physical_Drive_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless SCSI Tape Drive degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.SCSI_Tape_Drive_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless SCSI Tape Drive failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.SCSI_Tape_Drive_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless SCSI Tape Library failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.SCSI_Tape_Library_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Solid State Disk degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Solid_State_Disk_Status_Change.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage System Connection degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Connection_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage System Fan degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Fan_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage System Fault Tolerant Power Supply degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Fault_Tolerant_Power_Supply_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage system Global Service Indicator Status Change. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Global_Service_Indicator.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage System Power Supply degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Power_Supply_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage System Power Supply UPS degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Power_Supply_UPS_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage System Recovery Server degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Recovery_Server_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage System Side Panel degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Side_Panel_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage System Temperature degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Temperature_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Storage System Temperature failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Storage_System_Temperature_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless USB storage device sync failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.SyncOperation_Flash_Media_failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless System Battery Failed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.System_Battery_Failed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless System Battery Removed. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.System_Battery_Removed.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Temperature degraded. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Temperature_degraded.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Temperature failed and system shutdown. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Temperature_failed_and_system_shutdown.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |
| HPE Agentless Test alert. | HewlettPackard.ProLiant.Monitored.Agentless.SNMP.Test_Alert.Rule | HewlettPackard.ProLiant.Monitored.Agentless.HPAgentlessServer | Alert | True | True |