Lenovo Hardware Management Pack for ThinkServer BMC

Lenovo.ThinkServer.BMC.Module :: 7.6.0.8 (Management Pack)

Management Pack Elements

Classes (15)

 DisplayNameIDBase ClassAbstractHostedSingletonGroupExtensionAccessibility
Lenovo.ThinkServer.BMCLenovo ThinkServer BMC ModuleLenovo.ThinkServer.BMCSystem.LogicalHardwareFalseFalseFalseFalseFalsePublic
Lenovo.ThinkServer.GroupLenovo ThinkServer GroupLenovo.ThinkServer.GroupMicrosoft.SystemCenter.InstanceGroupFalseFalseTrueTrueFalsePublic
Class_ThinkServer.BMC.BaseSubModuleClass_ThinkServer.BMC.BaseSubModuleClass_ThinkServer.BMC.BaseSubModuleSystem.LogicalHardwareTrueFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.EthernetClass_ThinkServer.BMC.EthernetClass_ThinkServer.BMC.EthernetClass_ThinkServer.BMC.NICFalseFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.FanClass_ThinkServer.BMC.FanClass_ThinkServer.BMC.FanClass_ThinkServer.BMC.BaseSubModuleFalseFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.FCClass_ThinkServer.BMC.FCClass_ThinkServer.BMC.FCClass_ThinkServer.BMC.NICFalseFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.IBClass_ThinkServer.BMC.IBClass_ThinkServer.BMC.IBClass_ThinkServer.BMC.NICFalseFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.NICClass_ThinkServer.BMC.NICClass_ThinkServer.BMC.NICClass_ThinkServer.BMC.BaseSubModuleTrueFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.NumericSensorClass_ThinkServer.BMC.NumericSensorClass_ThinkServer.BMC.NumericSensorClass_ThinkServer.BMC.BaseSubModuleFalseFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.PCIClass_ThinkServer.BMC.PCIClass_ThinkServer.BMC.PCIClass_ThinkServer.BMC.BaseSubModuleFalseFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.PhysicalMemoryClass_ThinkServer.BMC.PhysicalMemoryClass_ThinkServer.BMC.PhysicalMemoryClass_ThinkServer.BMC.BaseSubModuleFalseTrueFalseFalseFalsePublic
Class_ThinkServer.BMC.PortClass_ThinkServer.BMC.PortClass_ThinkServer.BMC.PortClass_ThinkServer.BMC.BaseSubModuleFalseFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.ProcessorClass_ThinkServer.BMC.ProcessorClass_ThinkServer.BMC.ProcessorClass_ThinkServer.BMC.BaseSubModuleFalseTrueFalseFalseFalsePublic
Class_ThinkServer.BMC.RAIDClass_ThinkServer.BMC.RAIDClass_ThinkServer.BMC.RAIDClass_ThinkServer.BMC.BaseSubModuleFalseFalseFalseFalseFalsePublic
Class_ThinkServer.BMC.SoftwareIndentityClass_ThinkServer.BMC.SoftwareIndentityClass_ThinkServer.BMC.SoftwareIndentityClass_ThinkServer.BMC.BaseSubModuleFalseFalseFalseFalseFalsePublic

Relationship Types (2)

 IDSourceTargetAccessibilityAbstract
Lenovo.Relation.ThinkServer.BMCVsMemoryLenovo.Relation.ThinkServer.BMCVsMemoryLenovo.ThinkServer.BMCClass_ThinkServer.BMC.PhysicalMemoryPublicFalse
Lenovo.Relation.ThinkServer.BMCVsProcessorLenovo.Relation.ThinkServer.BMCVsProcessorLenovo.ThinkServer.BMCClass_ThinkServer.BMC.ProcessorPublicFalse

DataSource Modules (2)

 IDIsolationAccessibility
Lenovo.HardwareMgmtPack.BMC.Connection.HealthProviderLenovo.HardwareMgmtPack.BMC.Connection.HealthProviderAnyPublic
Lenovo.ThinkServer.BMC.DiscoverLenovo.ThinkServer.BMC.DiscoverAnyPublic

Unit Monitor Types (2)

 IDAccessibilitySupport Monitor Recalculate
Lenovo.BMC.Connection.MonitorTypeLenovo.BMC.Connection.MonitorTypeInternalFalse
Lenovo.ThinkServer.3StateLenovo.ThinkServer.3StatePublicFalse

Categories (6)

 IDTarget
Cat.Lenovo.HardwareMgmtPack.BMC.ManagementModule.Task.DeleteBMCCat.Lenovo.HardwareMgmtPack.BMC.ManagementModule.Task.DeleteBMCLenovo.HardwareMgmtPack.BMC.ManagementModule.Task.DeleteBMC
Cat.Lenovo.ThinkServer.Task.RegisterLXCACat.Lenovo.ThinkServer.Task.RegisterLXCALenovo.ThinkServer.Task.RegisterLXCA
Cat.Lenovo.WinComputer.BMC.RemotePresentCat.Lenovo.WinComputer.BMC.RemotePresentLenovo.WinComputer.BMC.RemotePresent
Cat.Lenovo.WinComputer.BMC.WebConsoleCat.Lenovo.WinComputer.BMC.WebConsoleLenovo.WinComputer.BMC.WebConsole
Cat.Lenovo.XClarity.ForumCat.Lenovo.XClarity.ForumLenovo.XClarity.Forum
Cat.Lenovo.XClarity.IdeationCat.Lenovo.XClarity.IdeationLenovo.XClarity.Ideation

Discoveries (2)

 IDTargetEnabled
Lenovo.ThinkServer.BMC.DiscoveryLenovo.ThinkServer.BMC.DiscoveryMicrosoft.SystemCenter.ManagementServerFalse
Lenovo.ThinkServer.Group.DiscoveryRuleLenovo.ThinkServer.Group.DiscoveryRuleLenovo.ThinkServer.GroupTrue

Aggregate Monitors (9)

 DisplayNameIDTargetAlgorithmCategoryEnabledAlert GenerateAccessibility
Lenovo.ThinkServer.CompatibilityCheck.RollupLenovo ThinkServer Compatibility Check Health RollupLenovo.ThinkServer.CompatibilityCheck.RollupLenovo.ThinkServer.BMCWorstOfCustomTrueFalsePublic
Lenovo.ThinkServer.CoolingDevicesMonitor.RollupLenovo ThinkServer Cooling Devices Health RollupLenovo.ThinkServer.CoolingDevicesMonitor.RollupLenovo.ThinkServer.BMCWorstOfCustomTrueFalsePublic
Lenovo.ThinkServer.DriveMonitor.RollupLenovo ThinkServer Hard Disk Drive Health RollupLenovo.ThinkServer.DriveMonitor.RollupLenovo.ThinkServer.BMCWorstOfCustomTrueFalsePublic
Lenovo.ThinkServer.MemoryMonitor.RollupLenovo ThinkServer Memory Health RollupLenovo.ThinkServer.MemoryMonitor.RollupLenovo.ThinkServer.BMCWorstOfCustomTrueFalsePublic
Lenovo.ThinkServer.NetworkMonitor.RollupLenovo ThinkServer Network Health RollupLenovo.ThinkServer.NetworkMonitor.RollupLenovo.ThinkServer.BMCWorstOfCustomTrueFalsePublic
Lenovo.ThinkServer.PowerModulesMonitor.RollupLenovo ThinkServer Power Modules Health RollupLenovo.ThinkServer.PowerModulesMonitor.RollupLenovo.ThinkServer.BMCWorstOfCustomTrueFalsePublic
Lenovo.ThinkServer.ProcessorMonitor.RollupLenovo ThinkServer Processors Health RollupLenovo.ThinkServer.ProcessorMonitor.RollupLenovo.ThinkServer.BMCWorstOfCustomTrueFalsePublic
Lenovo.ThinkServer.SensorMonitor.RollupLenovo ThinkServer Sensor Health RollupLenovo.ThinkServer.SensorMonitor.RollupLenovo.ThinkServer.BMCWorstOfCustomTrueFalsePublic
Lenovo.ThinkServer.SystemMonitor.RollupLenovo ThinkServer System Health RollupLenovo.ThinkServer.SystemMonitor.RollupLenovo.ThinkServer.BMCWorstOfCustomTrueFalsePublic

Unit Monitors (121)

 DisplayNameIDTargetCategoryEnabledAlert GenerateAccessibility
Lenovo.ThinkServer.BatteryFailedHealth monitor for battery failureLenovo.ThinkServer.BatteryFailedLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.BatteryLowHealth monitor for battery levelLenovo.ThinkServer.BatteryLowLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.BusCorrectableErrorHealth monitor for bus correctable failureLenovo.ThinkServer.BusCorrectableErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.BusFatalHealth monitor for bus fatal failureLenovo.ThinkServer.BusFatalLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.BusTimeoutHealth monitor for bus timeoutLenovo.ThinkServer.BusTimeoutLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.BusUncorrectableErrorHealth monitor for bus uncorrectable failureLenovo.ThinkServer.BusUncorrectableErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CoolingDeviceAbsentHealth monitor for cooling device presenceLenovo.ThinkServer.CoolingDeviceAbsentLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CoolingDeviceRedundancyLostHealth monitor for cooling device redundancyLenovo.ThinkServer.CoolingDeviceRedundancyLostLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CPUPowerLowerCriLowSensorMonitorHealth monitor for CPU Power lower critical going low sensorLenovo.ThinkServer.CPUPowerLowerCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CPUPowerLowerNonCriLowSensorMonitorHealth monitor for CPU Power lower non-critical going low sensorLenovo.ThinkServer.CPUPowerLowerNonCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CPUPowerLowerNonRecLowSensorMonitorHealth monitor for CPU Power lower non-recoverable going low sensorLenovo.ThinkServer.CPUPowerLowerNonRecLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CPUPowerUpperCriHighSensorMonitorHealth monitor for CPU Power upper critical going high sensorLenovo.ThinkServer.CPUPowerUpperCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CPUPowerUpperNonCriHighSensorMonitorHealth monitor for CPU Power upper non-critical going high sensorLenovo.ThinkServer.CPUPowerUpperNonCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CPUPowerUpperNonRecHighSensorMonitorHealth monitor for CPU Power upper non-recoverable going high sensorLenovo.ThinkServer.CPUPowerUpperNonRecHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurLowerCriHighSensorMonitorHealth monitor for current lower critical going high sensorLenovo.ThinkServer.CurLowerCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurLowerCriLowSensorMonitorHealth monitor for current lower critical going low sensorLenovo.ThinkServer.CurLowerCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurLowerNonCriHighSensorMonitorHealth monitor for current lower non-critical going high sensorLenovo.ThinkServer.CurLowerNonCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurLowerNonCriLowSensorMonitorHealth monitor for current lower non-critical going low sensorLenovo.ThinkServer.CurLowerNonCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurLowerNonRecHighSensorMonitorHealth monitor for current lower non-recoverable going high sensorLenovo.ThinkServer.CurLowerNonRecHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurLowerNonRecLowSensorMonitorHealth monitor for current lower non-recoverable going low sensorLenovo.ThinkServer.CurLowerNonRecLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurUpperCriHighSensorMonitorHealth monitor for current upper critical going high sensorLenovo.ThinkServer.CurUpperCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurUpperCriLowSensorMonitorHealth monitor for current upper critical going low sensorLenovo.ThinkServer.CurUpperCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurUpperNonCriHighSensorMonitorHealth monitor for current upper non-critical going high sensorLenovo.ThinkServer.CurUpperNonCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurUpperNonCriLowSensorMonitorHealth monitor for current upper non-critical going low sensorLenovo.ThinkServer.CurUpperNonCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurUpperNonRecHighSensorMonitorHealth monitor for current upper non-recoverable going high sensorLenovo.ThinkServer.CurUpperNonRecHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.CurUpperNonRecLowSensorMonitorHealth monitor for current upper non-recoverable going low sensorLenovo.ThinkServer.CurUpperNonRecLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.DiagnosticInterruptHealth monitor for Front Panel NMILenovo.ThinkServer.DiagnosticInterruptLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.DriveBayViolationHealth monitor for chassis intrusion - drive bay violationLenovo.ThinkServer.DriveBayViolationLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanAreaIntrusionHealth monitor for fan area intrusionLenovo.ThinkServer.FanAreaIntrusionLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanLowerCriHighHealth monitor for fan lower critical going high sensorLenovo.ThinkServer.FanLowerCriHighLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanLowerCriLowHealth monitor for fan lower critical going low sensorLenovo.ThinkServer.FanLowerCriLowLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanLowerNonCriHighHealth monitor for fan lower non-critical going high sensorLenovo.ThinkServer.FanLowerNonCriHighLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanLowerNonCriLowHealth monitor for fan lower non-critical going low sensorLenovo.ThinkServer.FanLowerNonCriLowLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanLowerNonRecHighHealth monitor for fan lower non-recoverable going high sensorLenovo.ThinkServer.FanLowerNonRecHighLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanLowerNonRecLowHealth monitor for fan lower non-recoverable going low sensorLenovo.ThinkServer.FanLowerNonRecLowLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanRedundancyLostHealth monitor for fan redundancyLenovo.ThinkServer.FanRedundancyLostLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanRemovedHealth monitor for fan presenceLenovo.ThinkServer.FanRemovedLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanUpperCriHighHealth monitor for fan upper critical going high sensorLenovo.ThinkServer.FanUpperCriHighLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanUpperCriLowHealth monitor for fan upper critical going low sensorLenovo.ThinkServer.FanUpperCriLowLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanUpperNonCriHighHealth monitor for fan upper non-critical going high sensorLenovo.ThinkServer.FanUpperNonCriHighLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanUpperNonCriLowHealth monitor for fan upper non-critical going low sensorLenovo.ThinkServer.FanUpperNonCriLowLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanUpperNonRecHighHealth monitor for fan upper non-recoverable going high sensorLenovo.ThinkServer.FanUpperNonRecHighLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FanUpperNonRecLowHealth monitor for fan upper non-recoverable going low sensorLenovo.ThinkServer.FanUpperNonRecLowLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FRUFailureHealth monitor for FRU failureLenovo.ThinkServer.FRUFailureLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FWInvalidHealth monitor for firmware validationLenovo.ThinkServer.FWInvalidLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.FWSWIncompatibilityHealth monitor for firmware or software compatibilityLenovo.ThinkServer.FWSWIncompatibilityLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.HDDCriArrayHealth monitor for hard disk drive in critical arrayLenovo.ThinkServer.HDDCriArrayLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.HDDFailedArrayHealth monitor for hard disk drive in failed arrayLenovo.ThinkServer.HDDFailedArrayLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.HDDFaultHealth monitor for hard disk drive failureLenovo.ThinkServer.HDDFaultLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.HDDFaultLEDHealth monitor for hard disk drive fault LEDLenovo.ThinkServer.HDDFaultLEDLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.HDDPredictiveFailureHealth monitor for hard disk drive predictive failureLenovo.ThinkServer.HDDPredictiveFailureLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.HWIncompatibilityHealth monitor for hardware compatibilityLenovo.ThinkServer.HWIncompatibilityLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.HWInvalidHealth monitor for hardware validationLenovo.ThinkServer.HWInvalidLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.InterconnnectConfigErrorHealth monitor for interconnect configurationLenovo.ThinkServer.InterconnnectConfigErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.IOCardAreaIntrusionHealth monitor for I/O card area intrusionLenovo.ThinkServer.IOCardAreaIntrusionLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.LANDisconnectedHealth monitor for Lan physical connectorLenovo.ThinkServer.LANDisconnectedLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.MCDisabledHealth monitor for management controllerLenovo.ThinkServer.MCDisabledLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.MemoryConfigErrorHealth monitor for memory configurationLenovo.ThinkServer.MemoryConfigErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.MemoryCorrectableECCErrorHealth monitor for memory correctable ECC statusLenovo.ThinkServer.MemoryCorrectableECCErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.MemoryParityErrorHealth monitor for memory parity errorLenovo.ThinkServer.MemoryParityErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.MemoryPredictiveFailureHealth monitor for memory predictive failureLenovo.ThinkServer.MemoryPredictiveFailureLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.MemoryScrubFailureHealth monitor for memory scrub failureLenovo.ThinkServer.MemoryScrubFailureLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.MemoryThrottledHealth monitor for memory throttledLenovo.ThinkServer.MemoryThrottledLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.MemoryUNCorrectableECCErrorHealth monitor for memory uncorrectable ECC statusLenovo.ThinkServer.MemoryUNCorrectableECCErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.NMIFatalHealth monitor for fatal NMILenovo.ThinkServer.NMIFatalLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.NMISWHealth monitor for software NMILenovo.ThinkServer.NMISWLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PCIFaultHealth monitor for PCI faultLenovo.ThinkServer.PCIFaultLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PCIPERRHealth monitor for PCI PERRLenovo.ThinkServer.PCIPERRLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PCISERRHealth monitor for PCI SERRLenovo.ThinkServer.PCISERRLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PhSecViolationHealth monitor for chassis intrusion - physical security violationLenovo.ThinkServer.PhSecViolationLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PostErrorHealth monitor for BIOS POST code errorLenovo.ThinkServer.PostErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.ProcAreaIntrusionHealth monitor for processor area intrusionLenovo.ThinkServer.ProcAreaIntrusionLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.ProcessorBIOSUncorrectableErrorHealth monitor for processor status in BIOSLenovo.ThinkServer.ProcessorBIOSUncorrectableErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.ProcessorConfigErrorHealth monitor for processor configurationLenovo.ThinkServer.ProcessorConfigErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.ProcessorFRB1FailedHealth monitor for processor FRB1 failureLenovo.ThinkServer.ProcessorFRB1FailedLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.ProcessorFRB2FailedHealth monitor for processor FRB2 failureLenovo.ThinkServer.ProcessorFRB2FailedLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.ProcessorFRB3FailedHealth monitor for processor FRB3 failureLenovo.ThinkServer.ProcessorFRB3FailedLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.ProcessorInternalErrorHealth monitor for processor internal failureLenovo.ThinkServer.ProcessorInternalErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.ProcessorThermalTripHealth monitor for processor thermal tripLenovo.ThinkServer.ProcessorThermalTripLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.ProcessorThrottleHealth monitor for processor speedLenovo.ThinkServer.ProcessorThrottleLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PSACLostHealth monitor for power supply ACLenovo.ThinkServer.PSACLostLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PSConfigErrorHealth monitor for power supply configurationLenovo.ThinkServer.PSConfigErrorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PSDeassertedHealth monitor for power supply presenceLenovo.ThinkServer.PSDeassertedLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PSFailureDetectedHealth monitor for power supply failure detectedLenovo.ThinkServer.PSFailureDetectedLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PSFailurePredictedHealth monitor for power supply failure predictLenovo.ThinkServer.PSFailurePredictedLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PSInpLstOrORHealth monitor for power supply input lost or out-of-rangeLenovo.ThinkServer.PSInpLstOrORLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PSInpLstOrORBtPresHealth monitor for power supply input out-of-range but presentLenovo.ThinkServer.PSInpLstOrORBtPresLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PSRedundancyLostHealth monitor for power supply redundancyLenovo.ThinkServer.PSRedundancyLostLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PSWarningHealth monitor for power supply warningLenovo.ThinkServer.PSWarningLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PUFailureHealth monitor for power unit failureLenovo.ThinkServer.PUFailureLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PUPredictiveFailureHealth monitor for power unit predictive failureLenovo.ThinkServer.PUPredictiveFailureLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.PUSPCFailureHealth monitor for power unit soft power controlLenovo.ThinkServer.PUSPCFailureLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.SELStatusEventLogSensorMonitorHealth monitor for Sel Status all event logging disabled sensorLenovo.ThinkServer.SELStatusEventLogSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.SWPCFailureHealth monitor for soft power controlLenovo.ThinkServer.SWPCFailureLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempLowerCritHighSensorMonitorHealth monitor for temperature lower critical going high sensorLenovo.ThinkServer.TempLowerCritHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempLowerCritLowSensorMonitorHealth monitor for temperature lower critical going low sensorLenovo.ThinkServer.TempLowerCritLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempLowerNonCritHighSensorMonitorHealth monitor for temperature lower non-critical going high sensorLenovo.ThinkServer.TempLowerNonCritHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempLowerNonCritLowSensorMonitorHealth monitor for temperature lower non-critical going low sensorLenovo.ThinkServer.TempLowerNonCritLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempLowerNonRecHighSensorMonitorHealth monitor for temperature lower non-recoverable going high sensorLenovo.ThinkServer.TempLowerNonRecHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempLowerNonRecLowSensorMonitorHealth monitor for temperature lower non-recoverable going low sensorLenovo.ThinkServer.TempLowerNonRecLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempUpperCriHighSensorMonitorHealth monitor for temperature upper critical going high sensorLenovo.ThinkServer.TempUpperCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempUpperCriLowSensorMonitorHealth monitor for temperature upper critical going low sensorLenovo.ThinkServer.TempUpperCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempUpperNonCriHighSensorMonitorHealth monitor for temperature upper non-critical going high sensorLenovo.ThinkServer.TempUpperNonCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempUpperNonCriLowSensorMonitorHealth monitor for temperature upper non-critical going low sensorLenovo.ThinkServer.TempUpperNonCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempUpperNonRecHighSensorMonitorHealth monitor for temperature upper non-recoverable going high sensorLenovo.ThinkServer.TempUpperNonRecHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.TempUpperNonRecLowSensorMonitorHealth monitor for temperature upper non-recoverable going low sensorLenovo.ThinkServer.TempUpperNonRecLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.UnauthDockHealth monitor for unauthorized dockLenovo.ThinkServer.UnauthDockLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.UnknownHWFailureHealth monitor for unknown hardware failureLenovo.ThinkServer.UnknownHWFailureLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltLowerCriHighSensorMonitorHealth monitor for voltage lower critical going high sensorLenovo.ThinkServer.VoltLowerCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltLowerCriLowSensorMonitorHealth monitor for voltage lower critical going low sensorLenovo.ThinkServer.VoltLowerCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltLowerNonCriHighSensorMonitorHealth monitor for voltage lower non-critical going high sensorLenovo.ThinkServer.VoltLowerNonCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltLowerNonCriLowSensorMonitorHealth monitor for voltage lower non-critical going low sensorLenovo.ThinkServer.VoltLowerNonCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltLowerNonRecHighSensorMonitorHealth monitor for voltage lower non-recoverable going high sensorLenovo.ThinkServer.VoltLowerNonRecHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltLowerNonRecLowSensorMonitorHealth monitor for voltage lower non-recoverable going low sensorLenovo.ThinkServer.VoltLowerNonRecLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltUpperCriHighSensorMonitorHealth monitor for voltage upper critical going high sensorLenovo.ThinkServer.VoltUpperCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltUpperCriLowSensorMonitorHealth monitor for voltage upper critical going low sensorLenovo.ThinkServer.VoltUpperCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltUpperNonCriHighSensorMonitorHealth monitor for voltage upper non-critical going high sensorLenovo.ThinkServer.VoltUpperNonCriHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltUpperNonCriLowSensorMonitorHealth monitor for voltage upper non-critical going low sensorLenovo.ThinkServer.VoltUpperNonCriLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltUpperNonRecHighSensorMonitorHealth monitor for voltage upper non-recoverable going high sensorLenovo.ThinkServer.VoltUpperNonRecHighSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.ThinkServer.VoltUpperNonRecLowSensorMonitorHealth monitor for voltage upper non-recoverable going low sensorLenovo.ThinkServer.VoltUpperNonRecLowSensorMonitorLenovo.ThinkServer.BMCCustomTrueFalsePublic
Lenovo.BMC.Connection.UnitMonitorLenovo.BMC.Connection.UnitMonitorLenovo.BMC.Connection.UnitMonitorLenovo.ThinkServer.BMCCustomTrueTruePublic

Rules (2)

 DisplayNameIDTargetCategoryEnabledAlert Generate
Lenovo.ThinkServer.ErrorAlert.RuleAlert for Lenovo ThinkServer Error EventsLenovo.ThinkServer.ErrorAlert.RuleLenovo.ThinkServer.BMCAlertTrueTrue
Lenovo.ThinkServer.WarningAlert.RuleAlert for Lenovo ThinkServer Warning EventsLenovo.ThinkServer.WarningAlert.RuleLenovo.ThinkServer.BMCAlertTrueTrue

Console Tasks (6)

 DisplayNameIDTargetAccessibilityEnabled
Lenovo.HardwareMgmtPack.BMC.ManagementModule.Task.DeleteBMC(Lenovo) Remove BMCLenovo.HardwareMgmtPack.BMC.ManagementModule.Task.DeleteBMCLenovo.ThinkServer.BMCPublicTrue
Lenovo.ThinkServer.Task.RegisterLXCA(Lenovo) XClarity AdministratorLenovo.ThinkServer.Task.RegisterLXCAMicrosoft.Windows.ComputerPublicFalse
Lenovo.WinComputer.BMC.RemotePresent(Lenovo) BMC Remote PresenceLenovo.WinComputer.BMC.RemotePresentLenovo.ThinkServer.BMCPublicTrue
Lenovo.WinComputer.BMC.WebConsole(Lenovo) BMC Web ConsoleLenovo.WinComputer.BMC.WebConsoleLenovo.ThinkServer.BMCPublicTrue
Lenovo.XClarity.Forum(Lenovo) XClarity ForumLenovo.XClarity.ForumLenovo.ThinkServer.BMCPublicTrue
Lenovo.XClarity.Ideation(Lenovo) XClarity IdeationLenovo.XClarity.IdeationLenovo.ThinkServer.BMCPublicTrue

Folder Items (12)

 DisplayNameIDFolderNameElementID
Lenovo.AlertView.ThinkServerActive AlertsLenovo.AlertView.ThinkServerFolder.Lenovo.ThinkServer.BMCLenovo.AlertView.ThinkServer
View_Cooling.DevicesCooling DevicesView_Cooling.DevicesFolder.Lenovo.ThinkServer.BMCView_Cooling.Devices
View_Fibre.ChannelFibre ChannelView_Fibre.ChannelFolder.Lenovo.ThinkServer.BMCView_Fibre.Channel
View_FirmwareVPDFirmware/VPDView_FirmwareVPDFolder.Lenovo.ThinkServer.BMCView_FirmwareVPD
View_IBInfiniBandView_IBFolder.Lenovo.ThinkServer.BMCView_IB
View_NetworkNetwork AdapterView_NetworkFolder.Lenovo.ThinkServer.BMCView_Network
View_PCIPCI DeviceView_PCIFolder.Lenovo.ThinkServer.BMCView_PCI
View_PMemoryPhysical MemoryView_PMemoryFolder.Lenovo.ThinkServer.BMCView_PMemory
View_ProcessorProcessorView_ProcessorFolder.Lenovo.ThinkServer.BMCView_Processor
View_RaidRAID ControllerView_RaidFolder.Lenovo.ThinkServer.BMCView_Raid
View_SensorNumeric SensorView_SensorFolder.Lenovo.ThinkServer.BMCView_Sensor
View_ThinkServer.BMCLenovo ThinkServer BMCView_ThinkServer.BMCIBM.ViewFolder.RootView_ThinkServer.BMC

Folders (1)

 DisplayNameIDParentFolderAccessibility
Folder.Lenovo.ThinkServer.BMCLenovo ThinkServer BMCFolder.Lenovo.ThinkServer.BMCIBM.ViewFolder.RootPublic

Views (12)

 DisplayNameIDTargetTypeAccessibilityVisible
Lenovo.AlertView.ThinkServerActive AlertsLenovo.AlertView.ThinkServerLenovo.ThinkServer.BMCMicrosoft.SystemCenter.AlertViewTypePublicTrue
View_Cooling.DevicesCooling DevicesView_Cooling.DevicesClass_ThinkServer.BMC.FanMicrosoft.SystemCenter.StateViewTypePublicTrue
View_Fibre.ChannelFibre ChannelView_Fibre.ChannelClass_ThinkServer.BMC.FCMicrosoft.SystemCenter.StateViewTypePublicTrue
View_FirmwareVPDFirmware/VPDView_FirmwareVPDClass_ThinkServer.BMC.SoftwareIndentityMicrosoft.SystemCenter.StateViewTypePublicTrue
View_IBInfiniBandView_IBClass_ThinkServer.BMC.IBMicrosoft.SystemCenter.StateViewTypePublicTrue
View_NetworkNetwork AdapterView_NetworkClass_ThinkServer.BMC.NICMicrosoft.SystemCenter.StateViewTypePublicFalse
View_PCIPCI DeviceView_PCIClass_ThinkServer.BMC.PCIMicrosoft.SystemCenter.StateViewTypePublicTrue
View_PMemoryPhysical MemoryView_PMemoryClass_ThinkServer.BMC.PhysicalMemoryMicrosoft.SystemCenter.StateViewTypePublicTrue
View_ProcessorProcessorView_ProcessorClass_ThinkServer.BMC.ProcessorMicrosoft.SystemCenter.StateViewTypePublicTrue
View_RaidRAID ControllerView_RaidClass_ThinkServer.BMC.RAIDMicrosoft.SystemCenter.StateViewTypePublicFalse
View_SensorNumeric SensorView_SensorClass_ThinkServer.BMC.NumericSensorMicrosoft.SystemCenter.StateViewTypePublicTrue
View_ThinkServer.BMCLenovo ThinkServer BMCView_ThinkServer.BMCLenovo.ThinkServer.BMCMicrosoft.SystemCenter.StateViewTypePublicTrue