ComTrade.Citrix.NetScaler.Appliance.Component.Network.InterfaceCitrix NetScaler Appliance Network Interface

ComTrade.Citrix.NetScaler.Appliance.Component.Network.Interface (ClassType)

Citrix NetScaler Appliance network Interface.

Element properties:

Base ClassComTrade.Citrix.NetScaler.Appliance.Component.Network.Base
AbstractTrue
HostedFalse
SingletonFalse
ExtensionFalse
AccessibilityPublic
ElementIdc148415c-e0a8-bbd0-c761-adec638237c3

Class Hierarchy:

Class Properties:

Property Name Type Display Name (ENU) Description (ENU) Key Max Length Min Length Case Sensitive
System.Entity:
DisplayName  string  Display Name Display name of monitoring object. false 256  False 
ComTrade.Citrix.NetScaler.Appliance.Component.Base:
HostID  string  MPNS Key The NetScaler Management Pack key value. It is combination of host id, serial number and NetScaler IP address. false 256  False 
IPAddress  string  Device IP Address The NetScaler Device IP Address. false 256  False 
DeviceKey  string  Device Key The key property of the device node in System Center Operations Manager. true 256  False 
ComTrade.Citrix.NetScaler.Appliance.Component.Network.Interface:
autoneg  string  Auto Negotiation The state of auto negotiation for the specified interface. Possible values are Enabled or Disabled. If auto negotiation is enabled on an interface then that interface tries to auto negotiate the speed and duplex settings with the link partner. If Speed or Duplex are set by the user other then AUTO, than auto negotiation of that parameter does not happen. false 256  False 
autonegresult  string  Auto Negotiation Result Actual auto negotiation setting for this interface. false 256  False 
bandwidthhigh  string  Bandwidth High Configured high threshold of the interface bandwidth usage in Mbits/s. Trap will be sent if bandwidth usage of the interface crosses this limit. false 256  False 
bandwidthnormal  string  Bandwidth Normal Configured normal threshold of the interface bandwidth usage in Mbits/s. Trap will be sent if bandwidth usage of the interface comes back to this limit. false 256  False 
conndistr  string  Connection Distribution Connection distribution setting on this interface. false 256  False 
description  string  Description Gives the information about the device: the type of interface, on which speeds this interface can operate and type of SFP, if applicable. false 256  False 
devicename  string  Device Name Name of the interface. false 256  False 
duplex  string  Duplex The requested duplex mode for the interface. Possible values are: 1. AUTO: Default setting. Indicates that the NetScaler will attempt to auto-negotiate the duplex mode of the interface when it is brought up. 2. HALF 3. FULL For settings other than AUTO, duplex and speed settings should be kept identical at both ends of the link for the it to be up. false 256  False 
flags  string  Flags Flags for this interface. This is used for communicating the device states. false 256  False 
flowctl  string  Flow Control The requested 802. 3x flow control setting for the interface. Possible values are OFF (the default), RX, TX, RXTX, and ON (\"forced RXTX\"). The 802.3x specification does not define flow control for 10 Mbps and 100 Mbps speeds, but if a Gigabit Ethernet interface operates at those speeds, the flow control settings can be applied. The flow control setting that is finally applied to an interface depends on auto-negotiation. With the ON option, auto-negotiation gives the peer the opportunity to negotiate the flow control, but the appliance then forces two-way flow control for the interface. Any other link-parameter mismatches can sometimes cause problems and should be avoided by thoroughly checking the settings. Default value: OFF Possible values = OFF, RX, TX, RXTX. false 256  False 
hamonitor  string  HA Monitor Triggers a failover when the interface on which it is enabled goes down. By default, this option is enabled on all interfaces. It is recommended that this option be disabled on all unused interfaces and other non-critical ones. false 256  False 
hangdetect  string  Hang Detection Hang detection enabled or disabled for this interface. false 256  False 
hangreset  string  Hang Reset Hang reset enabled or disabled for this interface. false 256  False 
id  string  ID The interface number in the a/b format. 'a' can take one of the following values: 1. '0': Indicates a management interface. 2. '1': Indicates a 10/100/1000 Mbps ports and 10G ports of NetScaler 12000-10G and NetScaler MPX 15000 and 17000 platforms. 3. '10': Indicates a 10 Gbps port. 4. 'LA': Indicates a link aggregation port. 5. 'LO': Indicates a loop back port. 'b' is an integer that is used to provide a unique label for the interfaces in the groups defined by 'a'. true 256  False 
ifalias  string  Alias Name The alias name for the interface. false 256  False 
lacpkey  string  LACP Key Identifies the LA channel to which the interface is bound. The possible values are 1, 2, 3, and 4. false 256  False 
lacpmode  string  Enable LACP The LACP mode of the specified interface. The possible values are: 1. Active: A port in active mode will generate LACP protocol messages on a regular basis, regardless of any need expressed by its partner to hear them. 2. Passive: A port in passive mode will generally not transmit LACP messages unless its partner is in the active mode; that is, it will not speak unless spoken to. 3. Disabled: Removes the interface from the LA channel. If this is only interface in the LA channel, the LA channel is also deleted. false 256  False 
lacppriority  string  LACP Priority LACP port priority expressed as an integer ranging from 1 to 65535. The highest priority is 1. The NetScaler limits the number of interfaces in an LA channel to 8. If LACP is enabled on more than 8 interfaces, NetScaler selects 8 interfaces, in descending order of port priority, to form a channel. false 256  False 
lacptimeout  string  LACP Timeout Time to wait for the LACPDU. If a LACPDU is not received within this interval, the NetScaler marks the link partner port as DOWN. Possible values are Long and Short. Long LACP timeout is 90 sec and Short LACP timeout is 3 sec. false 256  False 
mac  string  MAC MAC address for this interface. false 256  False 
macdistr  string  MAC Distribution MAC distribution setting on this interface. false 256  False 
mode  string  Mode Interface Link Aggregation mode(Auto/Manual) setting. false 256  False 
mtu  string  MTU MTU for this interface. It shows the maximum size of frame which can be delivered by this interface. false 256  False 
reqduplex  string  Requested Duplex Requested duplex setting for this interface. false 256  False 
reqflowcontrol  string  Requested Flow Control Requested flow control setting for this interface. false 256  False 
reqmedia  string  Requested Media Requested media setting for this interface. false 256  False 
reqspeed  string  Requested Speed Requested speed setting for this interface. false 256  False 
reqthroughput  string  Requested Throughput Minimum required throughput for an interface. If the interface is a logical interface (LA) and HAMON is ON on that interface then if the operating throughput of that interface falls below this value, failover is triggered. false 256  False 
speed  string  Speed The requested Ethernet speed of the interface. Possible values are: 1. AUTO: Default value. Indicates that the NetScaler will attempt to auto-negotiate or auto-sense the line speed of the interface when it is brought up. 2. 10, 100, 1000, and 10000: 10 Mbps, 100 Mbps, 1 Gbps, and 10 Gbps respectively. Setting a speed other than AUTO requires the device at the other end of the link to be configured identically. Mismatched speed and duplex settings will lead to link errors, packet loss, etc. Some interfaces do not support certain speeds. When an unsupported speed is set, an error is displayed. false 256  False 
tagall  string  Tag All The option to select whether this port is a trunk port or not for the interface. By default, this is set to OFF for all interfaces. When ON, the traffic will be tagged for all VLANs bound to this interface. If one wants 802.1q behavior with backward compatibility the OFF setting for this variable. false 256  False 
tagged  string  Tagged VLAN tags setting on this channel. false 256  False 
taggedany  string  Tagged Any Interface setting to accept/drop all tagged packets. false 256  False 
taggedautolearn  string  Tagged Auto Learn Dynamic VLAN membership auto learning enabled or disabled on this interface. false 256  False 
throughput  string  Throughput Minimum required throughput for an interface. If the interface is a logical interface (LA) and HAMON is ON on that interface then if the operating throughput of that interface falls below this value, failover is triggered. false 256  False 
trunk  string  Trunk This argument is deprecated by tag all. false 256  False 
unit  string  Unit Unit number for this interface; it shows the sequence number in which this interface is discovered on this NetScaler. false 256  False 
vlan  string  VLAN Native VLAN for this interface. false 256  False 
vmac  string  VMAC Virtual MAC of this interface. false 256  False 
vmac6  string  VMAC6 Virtual MAC for IPv6 of this interface. false 256  False 

Health Model: