Monitors Power Supply 1 status for the appliance.
This monitor checks the Power Supply 1 status.
On a NetScaler MPX 7500 or NetScaler MPX 9500 appliance, you can install two power supply units. However, the appliance functions as expected with a single power supply unit. The second power supply unit is a backup unit. You must ensure that both power supply units are of the same type, either AC or DC.
NetScaler MPX 7500 appliances manufactured before February 2010 do not support the health monitoring of the second power supply unit.
Power Supply status can be one of the four:
NORMAL
FAILED
NOT PRESENT
NOT SUPPORTED
The status NOT SUPPORTED is added to distinguish the NetScaler MPX 7500 appliances with hardware that does not support the health monitoring of the power supply units from newly manufactured appliances.
NORMAL and NOT SUPPORTED are "Healthy" statuses.
The following configuration parameters are customizable:
CacheExpirationFactor - Cache expiration factor. Default value is 0.
IntervalSeconds - The recurring interval of time in seconds in which to run the script (the default value is set to 300 seconds).
SyncTime - The synchronization time specified by using a 24-hour format. No default value specified.
Debug - When true writes more info in events log. Default value is false.
Target | ComTrade.Citrix.NetScaler.Appliance | ||
Parent Monitor | System.Health.AvailabilityState | ||
Category | AvailabilityHealth | ||
Enabled | False | ||
Alert Generate | True | ||
Alert Severity | MatchMonitorHealth | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | ComTrade.Citrix.NetScaler.Monitoring.2State.UnitMonitorType | ||
Remotable | True | ||
Accessibility | Public | ||
Alert Message |
| ||
RunAs | Default |