Database Schema Incompatible (older) With Service

ComTrade.Citrix.XenDesktop.Service.Analytics.Status.DBOlderVersionThanService.Monitor (UnitMonitor)

Monitors if the version of the Analytics Service schema on the database is compatible with the version of the Analytics Service currently in use. It detects if the schema is older.

Element properties:

TargetComTrade.Citrix.XenDesktop.Service.Analytics
Parent MonitorSystem.Health.ConfigurationState
CategoryConfigurationHealth
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeComTrade.Citrix.XenDesktop.Service.Status.UnitMonitorType
RemotableTrue
AccessibilityPublic
Alert Message
Incompatible Version of Analytics Service

The version of the Analytics Service schema on the database is incompatible with the version of the Analytics Service currently in use. Upgrade the database schema to a more recent version.

Host: {0}
Service: {1}

Service Status: {2}
RunAsDefault