F5 BIG-IP Generic Monitoring Filtered Data Source

Comtrade.F5.BigIp.LTM.VirtualServerMonitoring.Filtered.DS (DataSourceModuleType)

Data source for F5 BIG-IP Generic Monitoring.

Element properties:

TypeDataSourceModuleType
IsolationAny
AccessibilityPublic
RunAsDefault
OutputTypeSystem.PropertyBagData

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Comtrade.F5.BigIp.LTM.VirtualServerMonitoring.DS Default
ObjectFilter ConditionDetection System.ExpressionFilter Default

Overrideable Parameters:

IDParameterTypeSelectorDisplay NameDescription
TimeoutSecondsint$Config/TimeoutSeconds$Timeout SecondsTimeout in seconds. This value is used for setting timeout value to access the BIG-IP appliance. Default value is 270 seconds.
IntervalSecondsint$Config/IntervalSeconds$Update Interval in SecondsRecurring scheduled interval in seconds used for running the workflow. Default value is 300 seconds.
UseCachebool$Config/UseCache$Use CacheIf true, cache will be used, in order to minimize impact of monitoring on the F5 BIG-IP device. Default value is true.
SyncTimestring$Config/SyncTime$Synchronization TimeSynchronization time in a 24-hour format. No default value is specified.
Debugbool$Config/Debug$DebugWhen true, writes more information into event log.