Active F5 BIG-IP Device Traffic 2 State Monitor Type

Comtrade.F5.BigIp.Monitoring.2State.ActiveDeviceTraffic.Delta.UnitMonitorType (UnitMonitorType)

Represents 2 state monitor type which checks if device traffic delta is below or equal to the threshold.

Element properties:

RunAsDefault
AccessibilityPublic
Support Monitor RecalculateFalse

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Comtrade.F5.BigIp.GenericMonitoring.DS.Device Default
DeltaChange ConditionDetection System.Performance.DeltaValueCondition Default
FilterDeltaValue ConditionDetection System.ExpressionFilter Default
FilterDeviceActive ConditionDetection System.ExpressionFilter Default
FilterMustExist ConditionDetection System.ExpressionFilter Default
FilterSuccess ConditionDetection System.ExpressionFilter Default
FilterWarning ConditionDetection System.ExpressionFilter Default
mapper ConditionDetection System.Performance.DataGenericMapper Default

Overrideable Parameters:

IDParameterTypeSelectorDisplay NameDescription
IntervalSecondsint$Config/IntervalSeconds$Update Interval in SecondsRecurring scheduled interval in seconds used for running the workflow.
UseCachebool$Config/UseCache$Use CacheIf true, cache will be used, in order to minimize impact of monitoring on the F5 BIG-IP device. Default value is true.
SyncTimestring$Config/SyncTime$Synchronization TimeSynchronization time in a 24-hour format.
Debugbool$Config/Debug$DebugWhen true, writes more information into event log. Default value is false.
Portint$Config/Port$PortPort for accessing the BIG-IP appliance. Default value is 443.
TimeoutSecondsint$Config/TimeoutSeconds$Timeout SecondsTimeout in seconds. This value is used for setting timeout value to access the BIG-IP appliance. Default value is 270 seconds.
Thresholddouble$Config/Threshold$ThresholdThreshold value (in bits). Default value is 0.