IPMI SDR Status

Comtrade.Nutanix.Monitor.Host.A1050 (UnitMonitor)

Monitor of Nutanix Alert A1050.

Knowledge Base article:

Summary

Nutanix Alert A1050 - IPMI Error

Causes

The IPMI interface is down.

There is a network connectivity issue.

The hypervisor password does not match what is configured in the cluster.

The cluster did not correctly fail back after a Controller VM was temporarily down.

Resolutions

Ensure that the IPMI interface is functioning.

Ensure that physical networking, VLANs, and virtual switches are configured correctly.

Ensure that the hypervisor password configured in the cluster matches the actual hypervisor password.

If the alert persists, contact Nutanix support.

Element properties:

TargetComtrade.Nutanix.Host
Parent MonitorSystem.Health.AvailabilityState
CategoryAlert
EnabledTrue
Alert GenerateTrue
Alert SeverityMatchMonitorHealth
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeComtrade.Nutanix.Monitor.Alert.3StateThresholdMonitor
RemotableTrue
AccessibilityPublic
Alert Message
Alert A1050 - {0}
{1}
RunAsDefault