Mismatching Security Key Identifiers
The causes and resolutions refer to the Dell Modular Disk Storage Manager recovery guru. Launch Dell Modular Disk Storage Manager to diagnose and fix the recovery failure as follows:
Open Start >> Programs >> Dell >> MD Storage Manager >> Modular Disk Storage Manager Client.
If the MD Storage Array is already being managed by MDSM, you can proceed with the Causes and Resolution sections.
From Edit -> Add Storage Array, provide the IP address of the MD Storage Array and Add it to the discovered devices configuration in order to manage it.
Select the MD Storage Array and follow the steps specified in this recovery guru.
At least two physical disk security key identifiers do not match the storage array security key identifier. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.
Caution: Electrostatic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touching components without using a proper ground can damage the equipment.
Important Notes
You can resolve this problem in two ways:
Importing a valid security key file into the storage array
Powering down the storage array and removing the affected physical disks so that only one security key is required to unlock all of the physical disks.
1 | Review the Recovery Guru Details area to identify which physical disks have been affected by this failure. | ||||||
2 | Determine which steps you would like to take to resolve this problem:
|
Importing a Security Key File
1 | From the Array Management Window, select the Storage Array > Security > Physical Disk Security > Import Key... menu option. |
2 | From the list of security key identifiers, select the security key file that corresponds to the affected physical disks. |
3 | Import the security key file by manually typing in the file name or clicking Select File to browse for the security key file. |
4 | Enter the correct pass phrase for the security key file. |
5 | Click Import to import the security key file. |
6 | Complete steps 2 - 5 for each reported security key identifier and affected physical disks. |
7 | Click the Recheck button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your Technical Support Representative. |
Removing the Affected Physical Disks
1 | Stop all I/O on the storage array. |
2 | Power down the storage array. |
3 | Remove the affected physical disks. |
4 | Turn the storage array back on. |
5 | Click the Recheck button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your Technical Support Representative. |
Target | Microsoft.SystemCenter.ManagementServer | ||
Category | Alert | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.ScriptGenerated.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
WriteToDW | WriteAction | Microsoft.SystemCenter.DataWarehouse.PublishEventData | Default |
<Rule ID="Dell.MDStorageArray.ABBXMLEvent387" Enabled="onEssentialMonitoring" Target="SystemCenter!Microsoft.SystemCenter.ManagementServer" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.ScriptGenerated.EventProvider">
<ComputerName>$Target/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<ScriptName>RBODEventGenerator</ScriptName>
<EventNumber>387</EventNumber>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Dell.MDStorageArray.ABBXMLEvent387.StringResource"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>