PCI normal state alert
PCI has generated normal alert.
Cause | Resolutions |
The component at bus <bus> device <device> function <func> recovered from a fatal IO error. | No response action is required. |
The component at slot <number> recovered from a fatal IO error. | No response action is required. |
Device option ROM on embedded NIC was successfully updated. | No response action is required. |
Virtual MAC address for component at bus <bus> device <device> function <func> was successfully programed. | No response action is required. |
Device option ROM on mezzanine card <number> was successfully updated. | No response action is required. |
Link Tuning or FlexAddress data successfully obtained. | No response action is required. |
PCIe is operating normally on a component at bus <bus> device <device> function <func>. | No response action is required. |
The component at bus <bus> device <device> function <func> recovered from a non-fatal IO error. | No response action is required. |
The QuickPath Interconnect (QPI) width regained. | No response action is required. |
The component at slot <number> recovered from a non-fatal PCIe error. | No response action is required. |
Device option ROM on mezzanine card was successfully updated. | No response action is required. |
New PCI card(s) have been detected in the system. Fan speeds may have changed to add additional cooling to the cards. | Changing default fan response to PCIe cards should be done with appropriate understanding of the PCIe cooling needs of the cards present in the system. If the automatic cooling response is insufficient, additional cooling can be added by one of the following methods. 1) From iDRAC Web GUI, click Hardware -> Fans -> Setup, then from the fan speed offset drop-down list appropriately select the cooling level needed or set the minimum fan speed to a custom value. 2) From F2 System Setup, select iDRAC Settings -> Thermal, and set a higher fan speed from the fan speed offset or minimum fan speed. 3) For RACADM commands run "racadm help system.thermalsettings". If a lower fan speed is required, contact your service provider for the appropriate IPMI commands to reduce the default fan speed response for new PCIe cards. |
The power-related issue of the PCIe adapter in slot <slot number> is resolved. | No response action is required. |
The auxiliary power-related issue of the PCIe adapter in slot <slot number> is resolved. | No response action is required. |
Additional information on this issue may be available. Launch the iDRAC Console to debug further.
Target | Dell.ManagedServer | ||
Category | Alert | ||
Enabled | True | ||
Event_ID | 2419 | ||
Event Source | LifeCycle Controller Log | ||
Alert Generate | True | ||
Alert Severity | Information | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | System |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
WriteToDW | WriteAction | Microsoft.SystemCenter.DataWarehouse.PublishEventData | Default |
<Rule ID="Dell.ManagedServer.Alert.2419" Enabled="true" Target="DellManagedServer!Dell.ManagedServer" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="DellManagedServer!Dell.ManagedServer"]/HostName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">2419</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">LifeCycle Controller Log</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="Health!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>0</Severity>
<AlertMessageId>$MPElement[Name="Dell.ManagedServer.Alert.2419.Rule"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>