Power Supply audit failure or critical event.
Cause | Resolution |
Unable to set the chassis redundancy policy to AC Redundancy. | Retry the operation using the CMC command line interface or CMC Web interface. To set the chassis redundancy policy using the command line, enter "racadm config -g cfgChassisPower -o cfgChassisRedundancyPolicy 1". To configure the chassis redundancy policy using the Web interface, click Chassis Overview > Power > Configuration. From the Redundancy drop-down menu, select AC Redundancy. |
The operation to read the FRU data from the PSU identified in the message did not complete successfully due to internal communication errors. | Retry the operation. If the condition persists, contact your service provider. |
The power supply unit (PSU) identified in the message was turned off because the temperature exceeded the high temperature threshold in the unit. | Remove and reinsert the PSU or remove AC power and reapply power to the PSU to get it functional again. |
Additional information on this issue may be available. Launch the iDRAC Console to debug further.
Target | Dell.ManagedServer | ||
Category | Alert | ||
Enabled | True | ||
Event_ID | 8329 | ||
Event Source | LifeCycle Controller Log | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | System |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
WriteToDW | WriteAction | Microsoft.SystemCenter.DataWarehouse.PublishEventData | Default |
<Rule ID="Dell.ManagedServer.Alert.8329" Enabled="true" Target="DellManagedServer!Dell.ManagedServer" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="DellManagedServer!Dell.ManagedServer"]/HostName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">8329</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">LifeCycle Controller Log</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="Health!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>2</Severity>
<AlertMessageId>$MPElement[Name="Dell.ManagedServer.Alert.8329.Rule"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>