Dell Server Power Supply Health
Dell Server Power Supply Unit Monitor
If Power Supply is in warning state, causes/resolutions for this condition:
Cause | Resolutions |
A predictive failure detected on power supply <number>. | Remove and re-install the power supply at the next service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. |
The power input for power supply <number> is outside of the allowable range, but it is attached to the system. | Verify the input power is within the operating requirements for the power supply. |
The temperature for power supply <number> is in a warning range. | Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures. |
Power supply in <Enclosure name> was disrupted. | Reconnect the power cable to the power supply unit if it was disconnected. Restore the input AC power supply. Make sure the power supply is restored to the enclosure from the mains. |
The power supply in <enclosure name> is switched OFF. | Reseat the power supply, check the cable connection and verify the power supply is turned on. See the storage hardware documentation for more information. |
Power supply redundancy is degraded. | Check the event log for power supply failures. Review system configuration and power consumption. |
If Power Supply is in critical state, causes/resolutions for this condition:
Cause | Resolutions |
Power supply <number> failed. | Remove and re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. |
The power input for power supply <number> is lost. | Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply. |
The power input for power supply <number> is outside of range. | Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply. |
Power supply <number> is incorrectly configured. | Install matched power supplies and review product documentation for proper configuration. |
Cannot communicate with power supply <number>. | Remove and re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. |
The temperature for power supply <number> is outside of range. | Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures. |
An under voltage fault detected on power supply <number>. |
|
An over voltage fault detected on power supply <number>. | Check input power, replace or re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. |
An over current fault detected on power supply <number>. |
|
Fan failure detected on power supply <number>. | Check for fan blockage. If not replace the power supply. |
A power supply wattage mismatch is detected; power supply <number> is rated for <value> watts. | Install matched power supplies and review product documentation for proper configuration. |
Power supply <number> vendor type mismatch detected. | Install matched power supplies and review product documentation for proper configuration. |
Power supply <number> revision mismatch detected. | Review product documentation, change power supply with correct revision. |
Power supply <number> voltage rating does not match the system"s requirements. | Review product documentation, change power supply with correct voltage rating. |
Power supply <number> is absent. | Install the power supply if needed. |
Power supply in <Enclosure name> has failed. | Check for other messages related to the state of the power supply/enclosure. These may help determine the cause of this event. Contact technical support if the issue still persists. |
<PSU Sensor Name> has failed. | Replace the device. |
Power supply redundancy is lost. | Check the event log for power supply failures. Review system configuration and power consumption. |
The power supplies are not redundant. Insufficient resources to maintain normal operations. | Check the event log for power supply failures. Review system configuration and power consumption and upgrade or install power supplies accordingly. |
Additional information on this issue may be available. Launch the iDRAC Console to debug further.
Target | Dell.ManagedServer.PSUnit |
Parent Monitor | System.Health.AvailabilityState |
Category | StateCollection |
Enabled | False |
Alert Generate | False |
Alert Auto Resolve | False |
Monitor Type | Dell.ManagedServer.ServerHealthCookDownUMT |
Remotable | True |
Accessibility | Public |
RunAs | Default |
<UnitMonitor ID="Dell.ManagedServer.PSUnitHealth" Accessibility="Public" Enabled="false" Target="DellManagedServer!Dell.ManagedServer.PSUnit" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" TypeID="Dell.ManagedServer.ServerHealthCookDownUMT" Priority="Normal" ConfirmDelivery="false">
<Category>StateCollection</Category>
<OperationalStates>
<OperationalState HealthState="Success" MonitorTypeStateID="Success" ID="Success"/>
<OperationalState HealthState="Error" MonitorTypeStateID="Error" ID="Critical"/>
<OperationalState HealthState="Warning" MonitorTypeStateID="Warning" ID="Warning"/>
</OperationalStates>
<Configuration>
<IntervalSeconds>21600</IntervalSeconds>
<SyncTime/>
<TimeoutSeconds>1200</TimeoutSeconds>
<InstanceIndex>$Target/Property[Type="DellManagedServer!Dell.ManagedServer.PSUnit"]/ID$</InstanceIndex>
<ComponentType>Dell.ManagedServer.PSUnit</ComponentType>
<LogLevel>0</LogLevel>
</Configuration>
</UnitMonitor>