Dell Server Processor Health
Dell Server Processor Unit Monitor
If Processor is in warning state, causes/resolutions for this condition:
Cause | Resolutions |
CPU <number> is disabled. | if unexpected, check presence, and system setup (BIOS) configuration. |
CPU <number> is throttled. | Review system logs for power or thermal exceptions. |
CPU <number> terminator is absent. | Check presence and reinstall the terminator. |
A predictive failure detected on CPU <number> voltage regulator module. |
|
The power input for CPU <number> voltage regulator module is outside of range, but it is attached to the system. |
|
If Processor is in critical state, causes/resolutions for this condition:
Cause | Resolutions |
CPU <number> has an internal error (IERR). | Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. |
CPU <number> has a thermal trip (over-temperature) event. | Review logs for fan failures, replace failed fans. If no fan failures are detected, check inlet temperature (if available) and reinstall processor heatsink. |
CPU <number> has failed the built-in self-test (BIST). |
|
CPU <number> is stuck in POST. |
|
CPU <number> failed to initialize. |
|
CPU <number> configuration is unsupported. | Review product documentation for supported CPU configurations. |
Unrecoverable CPU complex error detected on CPU <number>. |
|
CPU <number> initialization error detected. |
|
CPU <number> protocol error detected. |
|
CPU bus parity error detected. | Check system and operating system logs for exceptions. If no exceptions found, remove input power, reinstall the processor, then apply input power. |
CPU bus initialization error detected. |
|
CPU <number> machine check error detected. |
|
CPU <number> voltage regulator module failed. |
|
The power input for CPU <number> voltage regulator module is lost. |
|
The power input for CPU <number> voltage regulator module is outside of range. |
|
CPU <number> voltage regulator module is incorrectly configure. | Review product documentation for proper configuration and installation procedures. |
CPU <number> voltage regulator module is absent. | if removal was unintended, check presence and re-install . |
CPU <number> is absent | Verify processor installation. If present, reseat the processor. |
Additional information on this issue may be available. Launch the iDRAC Console to debug further.
Target | Dell.ManagedServer.ProcUnit |
Parent Monitor | System.Health.AvailabilityState |
Category | StateCollection |
Enabled | False |
Alert Generate | False |
Alert Auto Resolve | False |
Monitor Type | Dell.ManagedServer.ServerHealthCookDownUMT |
Remotable | True |
Accessibility | Public |
RunAs | Default |
<UnitMonitor ID="Dell.ManagedServer.ProcUnitHealth" Accessibility="Public" Enabled="false" Target="DellManagedServer!Dell.ManagedServer.ProcUnit" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" TypeID="Dell.ManagedServer.ServerHealthCookDownUMT" Priority="Normal" ConfirmDelivery="false">
<Category>StateCollection</Category>
<OperationalStates>
<OperationalState HealthState="Success" MonitorTypeStateID="Success" ID="Success"/>
<OperationalState HealthState="Error" MonitorTypeStateID="Error" ID="Critical"/>
<OperationalState HealthState="Warning" MonitorTypeStateID="Warning" ID="Warning"/>
</OperationalStates>
<Configuration>
<IntervalSeconds>21600</IntervalSeconds>
<SyncTime/>
<TimeoutSeconds>1200</TimeoutSeconds>
<InstanceIndex>$Target/Property[Type="DellManagedServer!Dell.ManagedServer.ProcUnit"]/DeviceID$</InstanceIndex>
<ComponentType>Dell.ManagedServer.ProcUnit</ComponentType>
<LogLevel>0</LogLevel>
</Configuration>
</UnitMonitor>