Dell CMC SNMP Trap : Current sensor has detected a failure value

Dell.ModularChassis.CMC2177 (Rule)

Dell CMC has generated current sensor failure trap.

Knowledge Base article:

Summary

Dell CMC Current sensor has detected a failure value.

Causes

Probable causes and corresponding resolutions for this condition are:

Cause

Resolutions

The system board < name > current is less than the lower critical threshold.

Review system power policy, check system logs for power related failures, and review system configuration changes.

The system board < name > current is greater than the upper critical threshold.

Review system power policy, check system logs for power related failures, and review system configuration changes.

The system board < name > current is outside of range.

Review system power policy, check system logs for power related failures, and review system configuration changes.

Disk drive bay < name > current is less than the lower critical threshold.

Review system power policy, check system logs for power related failures, and review system configuration changes.

Disk drive bay < name > current is greater than the upper critical threshold.

Review system power policy, check system logs for power related failures, and review system configuration changes.

Disk drive bay < name > current is outside of range.

Review system power policy, check system logs for power related failures, and review system configuration changes.

System level current is less than the lower critical threshold.

Review system power policy, check system logs for power related failures, and review system configuration changes.

System level current is greater than the upper critical threshold.

Review system power policy, check system logs for power related failures, and review system configuration changes.

System level current is outside of range.

Review system power policy, check system logs for power related failures, and review system configuration changes.

Chassis power level current is less than the lower critical threshold.

Review system power policy, check system logs for power related failures, and review system configuration changes.

Chassis power level current is greater than the upper critical threshold.

Review system power policy, check system logs for power related failures, and review system configuration changes.

Chassis power level current is outside of range.

Review system power policy, check system logs for power related failures, and review system configuration changes.

Resolutions

Launch the CMC Console to debug further.

Element properties:

TargetDell.ModularChassis.CMC
CategoryAvailabilityHealth
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
RemotableTrue
Alert Message
Dell Chassis Management Controller trap : Current sensor has detected a failure value
Dell CMC has generated current sensor failure trap.

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Dell.SNMPTrap.DSMT Default
Alert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="Dell.ModularChassis.CMC2177" Enabled="true" Target="DAD!Dell.ModularChassis.CMC" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="DS" TypeID="Dell.SNMPTrap.DSMT">
<IP>$Target/Property[Type="DAD!Dell.ModularChassis.CMC"]/IPAddress$</IP>
<ServiceTag>$Target/Property[Type="DAD!Dell.ModularChassis.CMC"]/ServiceTag$</ServiceTag>
<Status>Critical</Status>
<Severity>2</Severity>
<AllTraps>false</AllTraps>
<OIDProps>
<OIDProp>.1.3.6.1.4.1.674.10892.2.21.0.2177</OIDProp>
</OIDProps>
<EventOriginId>$Target/Id$</EventOriginId>
<PublisherId>$Target/Id$</PublisherId>
<PublisherName>Snmp Event</PublisherName>
<Channel>SnmpEvent</Channel>
<LoggingComputer/>
<EventNumber>2177</EventNumber>
<EventCategory>5</EventCategory>
<EventLevel>10</EventLevel>
<UserName/>
<Params/>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>2</Severity>
<AlertMessageId>$MPElement[Name="Dell.ModularChassis.CMC.Rule2177"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventData/DataItem/Property[@Name="Status"]$</AlertParameter1>
<AlertParameter2>$Data/EventData/DataItem/Property[@Name="EventNumber"]$</AlertParameter2>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="EventNumber"]$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="ServiceTag"]$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="Severity"]$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="drsCA2MessageID"]$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="drsCA2Message"]$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="drsCA2FQDD"]$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="drsChassisServiceTag"]$</SuppressionValue>
</Suppression>
<Custom1>Alert Message ID = $Data/EventData/DataItem/Property[@Name="drsCA2MessageID"]$</Custom1>
<Custom2>Alert Message = $Data/EventData/DataItem/Property[@Name="drsCA2Message"]$</Custom2>
<Custom3>Alert FQDD = $Data/EventData/DataItem/Property[@Name="drsCA2FQDD"]$</Custom3>
<Custom4>Alert Chassis Service Tag = $Data/EventData/DataItem/Property[@Name="drsChassisServiceTag"]$</Custom4>
<Custom5>Alert Status = $Data/EventData/DataItem/Property[@Name="drsCA2AlertStatus"]$</Custom5>
<Custom6>Alert Global Status = $Data/EventData/DataItem/Property[@Name="drsGlobalCurrStatus"]$</Custom6>
<Custom7>Alert Chassis Location = $Data/EventData/DataItem/Property[@Name="drsProductChassisLocation"]$</Custom7>
<Custom8>Alert Chassis Name = $Data/EventData/DataItem/Property[@Name="drsProductChassisName"]$</Custom8>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>