Temperature sensor detected a non-recoverable value
Sensor location: %Location in chassis%
Chassis location: %Name of chassis%
Previous state was: %State%
If sensor type is not discrete:
Temperature sensor value (in degrees Celsius): %Reading%
If sensor type is discrete:
Discrete temperature state: %State%
A temperature sensor on the backplane board, system board, or drive carrier in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and temperature sensor value are provided.
Cause | Resolutions |
The arg1 sensor has failed with a value ofarg2degrees Celsius. | Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider. |
A Critical message refers to a significant event that indicates actual or imminent loss of data or loss of function. Change the environment, such as cooling or power as appropriate, or replace the failed component.
Target | Dell.WindowsServer.Server | ||
Category | Alert | ||
Enabled | True | ||
Event Source | Server Administrator | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | System |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
WriteToDW | WriteAction | Microsoft.SystemCenter.DataWarehouse.PublishEventData | Default |
<Rule ID="Dell.WindowsServer.ServerAdministrator.Alert.1055" Enabled="true" Target="Dell.WindowsServer.Server" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="Windows!Microsoft.Windows.LogicalDevice"]/DeviceID$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<Or>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">1055</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">5055</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</Or>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">Server Administrator</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>2</Severity>
<AlertMessageId>$MPElement[Name="Dell.WindowsServer.Rule.1055"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>