Dell OMSA Power supply returned to normal

Dell.WindowsServer.ServerAdministrator.Alert.1352 (Rule)

Knowledge Base article:

Summary

Power supply returned to normal

Causes

A power supply has been reconnected or replaced. The sensor location, chassis location, previous state, and additional power supply status information are provided.

Cause

Resolutions

Power supply arg1 is operating normally.

No response action is required.

Resolutions

None

Element properties:

TargetDell.WindowsServer.Server
CategoryAlert
EnabledFalse
Event SourceServer Administrator
Alert GenerateTrue
Alert SeverityInformation
Alert PriorityNormal
RemotableTrue
Alert Message
Dell OMSA Power supply returned to normal
Event Description : {0}
Event LogSystem

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
Alert WriteAction System.Health.GenerateAlert Default
WriteToDW WriteAction Microsoft.SystemCenter.DataWarehouse.PublishEventData Default

Source Code:

<Rule ID="Dell.WindowsServer.ServerAdministrator.Alert.1352" Enabled="false" Target="Dell.WindowsServer.Server" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="Windows!Microsoft.Windows.LogicalDevice"]/DeviceID$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<Or>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">1352</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">5352</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</Or>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">Server Administrator</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>0</Severity>
<AlertMessageId>$MPElement[Name="Dell.WindowsServer.Rule.1352"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>