The controller battery Learn cycle has timed out.
The controller battery must be fully charged before the Learn cycle can begin. The battery may be unable to maintain a full charge causing the Learn cycle to timeout. Additionally, the battery must be able to maintain cached data for a specified period of time in the event of a power loss. For example, some batteries maintain cached data for 24 hours. If the battery is unable to maintain cached data for the required period of time, then the Learn cycle will timeout.
Cause | Resolutions |
The battery on arg1 learn cycle has timed out. | Replace the battery pack. The battery is unable to maintain a full charge. |
Replace the battery pack as the battery is unable to maintain a full charge.
Target | Dell.WindowsServer.Server | ||
Category | Alert | ||
Enabled | True | ||
Event_ID | 2178 | ||
Event Source | Server Administrator | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | System |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
WriteToDW | WriteAction | Microsoft.SystemCenter.DataWarehouse.PublishEventData | Default |
<Rule ID="Dell.WindowsServer.StorageManagement.Alert.2178" Enabled="true" Target="Dell.WindowsServer.Server" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="Windows!Microsoft.Windows.LogicalDevice"]/DeviceID$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">2178</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">Server Administrator</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Dell.WindowsServer.StorageManagement.Alert.2178.Rule"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>