Dell OMSS Hot spare SMART polling failed

Dell.WindowsServer.StorageManagement.Alert.2282 (Rule)

Knowledge Base article:

Summary

Hot spare SMART polling failed.

Causes

The controller firmware attempted a SMART polling on the hot spare but was unable to complete it. The controller has lost communication with the hot spare

Cause

Resolutions

Hot spare arg1 SMART polling has failed.arg2

Verify the health of the disk assigned as a hot spare. Replace the disk and reassign the hot spare. Make sure the cables are attached securely. See the storage hardware documentation for more information on checking the cables.

Resolutions

Check the health of the disk assigned as a hot spare. You may need to replace the disk and reassign the hot spare. Make sure the cables are attached securely. See the Cables Attached Correctly section in the Dell OpenManage Server Administrator Storage Management User's Guide for more information on checking the cables

Element properties:

TargetDell.WindowsServer.Server
CategoryAlert
EnabledTrue
Event_ID2282
Event SourceServer Administrator
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
RemotableTrue
Alert Message
Dell OMSS Hot spare SMART polling failed
Event Description: {0}
Event LogSystem

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
Alert WriteAction System.Health.GenerateAlert Default
WriteToDW WriteAction Microsoft.SystemCenter.DataWarehouse.PublishEventData Default

Source Code:

<Rule ID="Dell.WindowsServer.StorageManagement.Alert.2282" Enabled="true" Target="Dell.WindowsServer.Server" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="Windows!Microsoft.Windows.LogicalDevice"]/DeviceID$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">2282</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">Server Administrator</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>2</Severity>
<AlertMessageId>$MPElement[Name="Dell.WindowsServer.StorageManagement.Alert.2282.Rule"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>