Dell Remote Access : Server : Redundancy (fan or power supply) is in warning state

Dell.iDRAC7.SNMPTrap.2474 (Rule)

Knowledge Base article:

Summary

Redundancy (fan or power supply) warning state alert

Causes

Redundancy (fan or power supply) has generated warning alert. Probable causes and corresponding resolutions for this condition are:

Cause

Resolutions

Fan redundancy is degraded.

Remove and re-install failed fans or install additional fans.

Power supply redundancy is degraded.

Check the event log for power supply failures. Review system configuration and power consumption.

Resolutions

Additional information on this issue may be available. Launch the DRAC or OMSA Console to debug further.

Element properties:

TargetDell.RemoteAccess.iDRAC7
CategoryAvailabilityHealth
EnabledTrue
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityNormal
RemotableTrue
Alert Message
Dell Remote Access : Server : Redundancy (fan or power supply) is in warning state
{0}

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Dell.SNMPTrap.DSMT Default
Alert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="Dell.iDRAC7.SNMPTrap.2474" Enabled="true" Target="DAD!Dell.RemoteAccess.iDRAC7" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="DS" TypeID="Dell.SNMPTrap.DSMT">
<IP>$Target/Property[Type="DAD!Dell.RemoteAccess.RAC"]/IPAddress$</IP>
<CommunityString>$Target/Property[Type="DAD!Dell.RemoteAccess.RAC"]/CommunityString$</CommunityString>
<AllTraps>false</AllTraps>
<OIDProps>
<OIDProp>.1.3.6.1.4.1.674.10892.5.3.2.1.0.2474</OIDProp>
</OIDProps>
<EventOriginId>$Target/Id$</EventOriginId>
<PublisherId>$Target/Id$</PublisherId>
<PublisherName>iDRAC</PublisherName>
<Channel>SnmpEvent</Channel>
<LoggingComputer/>
<EventNumber>2474</EventNumber>
<EventCategory>5</EventCategory>
<EventLevel>10</EventLevel>
<UserName/>
<Params/>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Dell.iDRAC7.SNMPTrap.2474.Rule"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[5]/Value$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="drsAlertMessageID"]$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="drsAlertFQDD"]$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="drsAlertCurrentStatus"]$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/Property[@Name="drsSystemServiceTag"]$</SuppressionValue>
</Suppression>
<Custom1>Alert Message ID = $Data/EventData/DataItem/Property[@Name="drsAlertMessageID"]$ </Custom1>
<Custom2>Alert Message = $Data/EventData/DataItem/Property[@Name="drsAlertMessage"]$ </Custom2>
<Custom3>Alert Status = $Data/EventData/DataItem/Property[@Name="drsAlertCurrentStatus"]$ </Custom3>
<Custom4>Alert Service Tag = $Data/EventData/DataItem/Property[@Name="drsSystemServiceTag"]$ </Custom4>
<Custom5>Alert FQDN = $Data/EventData/DataItem/Property[@Name="drsAlertFQDN"]$ </Custom5>
<Custom6>Alert FQDD = $Data/EventData/DataItem/Property[@Name="drsAlertFQDD"]$ </Custom6>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>