Dell Remote Access : Chassis Management Controller detected a warning.

Dell.iDRAC7.SNMPTrap.2546 (Rule)

Knowledge Base article:

Summary

Chassis Management Controller detected a warning.

Causes

Cause

Resolution

The I/O module may have taken more time to boot than was expected or the I/O module did not boot.

Verify the I/O Module is turned on using CMC Web Interface or RACADM CLI and retry the operation. Otherwise, reinsert the I/O Module and retry the operation. If the problem persists, contact technical support.

CMC is unable to obtain the CPU information from the server specified in the message. This occurs if there is no communication between CMC and iDRAC.

Do the following: 1) Reset iDRAC. 2) Reset CMC. If the issue persists, contact your service provider.

CMC is unable to obtain the memory information from the server specified in the message. This occurs if there is no communication between CMC and iDRAC.

Do the following: 1) Reset iDRAC. 2) Reset CMC. If the issue persists, contact your service provider.

CMC is unable to obtain the link tuning or flex address information for the newly installed hardware (server, Input Output Module, or Mezzanine card), or is unable to send the link tuning or flex address information to iDRAC.

Make sure that the currently installed CMC firmware is the latest. Otherwise, update the CMC with the latest CMC firmware and retry the operation.

Unable to turn on the server specified in the message, because the available power is lesser than the requested power.

In the CMC Web interface, verify the available power and server power requirements. If sufficient power is available, retry the operation. Otherwise, increase the power cap value.

Resolutions

Additional information on this issue may be available. Launch the IDRAC/DRAC Console to debug further.

Element properties:

TargetDell.RemoteAccess.iDRAC7
CategoryAvailabilityHealth
EnabledTrue
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityNormal
RemotableTrue
Alert Message
Dell Remote Access : SChassis Management Controller detected a warning.
Event Description: {0}

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource System.NetworkManagement.SnmpTrapEventProvider Default
Alert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="Dell.iDRAC7.SNMPTrap.2546" Enabled="true" Target="DAD!Dell.RemoteAccess.iDRAC7" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="DS" TypeID="Node!System.NetworkManagement.SnmpTrapEventProvider">
<IP>$Target/Property[Type="DAD!Dell.RemoteAccess.RAC"]/IPAddress$</IP>
<OIDProps>
<OIDProp>.1.3.6.1.4.1.674.10892.5.3.2.1.0.2546</OIDProp>
</OIDProps>
<EventOriginId>$Target/Id$</EventOriginId>
<PublisherId>$Target/Id$</PublisherId>
<PublisherName>iDRAC</PublisherName>
<Channel>SnmpEvent</Channel>
<LoggingComputer/>
<EventNumber>2546</EventNumber>
<EventCategory>5</EventCategory>
<EventLevel>10</EventLevel>
<UserName/>
<Params/>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Dell.iDRAC7.SNMPTrap.2546.Rule"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[3]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[6]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[8]/Value$</SuppressionValue>
</Suppression>
<Custom1>Alert Message ID = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[3]/Value$ </Custom1>
<Custom2>Alert Message = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$ </Custom2>
<Custom3>Alert Status = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[5]/Value$ </Custom3>
<Custom4>Alert Service Tag = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[6]/Value$ </Custom4>
<Custom5>Alert FQDN = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[7]/Value$ </Custom5>
<Custom6>Alert FQDD = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[8]/Value$ </Custom6>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>