Dell Remote Access : Storage : Power Supply is in warning state

Dell.iDRAC7.SNMPTrap.4234 (Rule)

Knowledge Base article:

Summary

Power Supply warning state alert

Causes

Power Supply has generated warning alert. Probable causes and corresponding resolutions for this condition are:

Cause

Resolutions

Power supply in <Enclosure name> was disrupted.

Reconnect the power cable to the power supply unit if it was disconnected. Restore the input AC power supply. Make sure the power supply is restored to the enclosure from the mains.

The power supply in <enclosure name> is switched OFF.

Reseat the power supply, check the cable connection and verify the power supply is turned on. See the storage hardware documentation for more information.

Resolutions

Additional information on this issue may be available. Launch the DRAC or OMSA Console to debug further.

Element properties:

TargetDell.RemoteAccess.iDRAC7
CategoryAvailabilityHealth
EnabledTrue
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityNormal
RemotableTrue
Alert Message
Dell Remote Access : Storage : Power Supply is in warning state
{0}

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource System.NetworkManagement.SnmpTrapEventProvider Default
Alert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="Dell.iDRAC7.SNMPTrap.4234" Enabled="true" Target="DAD!Dell.RemoteAccess.iDRAC7" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="DS" TypeID="Node!System.NetworkManagement.SnmpTrapEventProvider">
<IP>$Target/Property[Type="DAD!Dell.RemoteAccess.RAC"]/IPAddress$</IP>
<OIDProps>
<OIDProp>.1.3.6.1.4.1.674.10892.5.3.2.2.0.4234</OIDProp>
</OIDProps>
<EventOriginId>$Target/Id$</EventOriginId>
<PublisherId>$Target/Id$</PublisherId>
<PublisherName>iDRAC</PublisherName>
<Channel>SnmpEvent</Channel>
<LoggingComputer/>
<EventNumber>4234</EventNumber>
<EventCategory>5</EventCategory>
<EventLevel>10</EventLevel>
<UserName/>
<Params/>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Dell.iDRAC7.SNMPTrap.4234.Rule"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[3]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[6]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[8]/Value$</SuppressionValue>
</Suppression>
<Custom1>Alert Message ID = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[3]/Value$ </Custom1>
<Custom2>Alert Message = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$ </Custom2>
<Custom3>Alert Status = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[5]/Value$ </Custom3>
<Custom4>Alert Service Tag = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[6]/Value$ </Custom4>
<Custom5>Alert FQDN = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[7]/Value$ </Custom5>
<Custom6>Alert FQDD = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[8]/Value$ </Custom6>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>