Enclosure warning state alert
Enclosure has generated warning alert. Probable causes and corresponding resolutions for this condition are:
Cause | Resolutions |
The <Enclosure Name> has a bad sensor <args>. | Refer to the storage hardware documentation for more information. |
Enclosure Management Module (EMM) firmware version mismatch detected in <enclosure name>.<EMM 0 version> <EMM 1 version>. | Upgrade to the same version of the firmware on both EMM modules. |
Firmware download on <Enclosure Name> has failed. | Attempt to download the enclosure firmware again. If problems continue, verify that the controller can communicate with the enclosure. Make sure that the enclosure is powered ON. Refer to the storage hardware documentation for information on checking the cables. |
Additional information on this issue may be available. Launch the DRAC or OMSA Console to debug further.
Target | Dell.RemoteAccess.iDRAC7 | ||
Category | AvailabilityHealth | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | System.NetworkManagement.SnmpTrapEventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Dell.iDRAC7.SNMPTrap.4338" Enabled="true" Target="DAD!Dell.RemoteAccess.iDRAC7" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="DS" TypeID="Node!System.NetworkManagement.SnmpTrapEventProvider">
<IP>$Target/Property[Type="DAD!Dell.RemoteAccess.RAC"]/IPAddress$</IP>
<OIDProps>
<OIDProp>.1.3.6.1.4.1.674.10892.5.3.2.2.0.4338</OIDProp>
</OIDProps>
<EventOriginId>$Target/Id$</EventOriginId>
<PublisherId>$Target/Id$</PublisherId>
<PublisherName>iDRAC</PublisherName>
<Channel>SnmpEvent</Channel>
<LoggingComputer/>
<EventNumber>4338</EventNumber>
<EventCategory>5</EventCategory>
<EventLevel>10</EventLevel>
<UserName/>
<Params/>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Dell.iDRAC7.SNMPTrap.4338.Rule"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[3]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[6]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[8]/Value$</SuppressionValue>
</Suppression>
<Custom1>Alert Message ID = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[3]/Value$ </Custom1>
<Custom2>Alert Message = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$ </Custom2>
<Custom3>Alert Status = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[5]/Value$ </Custom3>
<Custom4>Alert Service Tag = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[6]/Value$ </Custom4>
<Custom5>Alert FQDN = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[7]/Value$ </Custom5>
<Custom6>Alert FQDD = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[8]/Value$ </Custom6>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>