Dell Remote Access : Power Supply audit failure or critical event.

Dell.iDRAC7.SNMPTrap.8329 (Rule)

Knowledge Base article:

Summary

Power Supply audit failure or critical event.

Causes

Cause

Resolution

Unable to set the chassis redundancy policy to AC Redundancy.

Retry the operation using the CMC command line interface or CMC Web interface. To set the chassis redundancy policy using the command line, enter "racadm config -g cfgChassisPower -o cfgChassisRedundancyPolicy 1". To configure the chassis redundancy policy using the Web interface, click Chassis Overview > Power > Configuration. From the Redundancy drop-down menu, select AC Redundancy.

The operation to read the FRU data from the PSU identified in the message did not complete successfully due to internal communication errors.

Retry the operation. If the condition persists, contact your service provider.

The power supply unit (PSU) identified in the message was turned off because the temperature exceeded the high temperature threshold in the unit.

Remove and reinsert the PSU or remove AC power and reapply power to the PSU to get it functional again.

Resolutions

Additional information on this issue may be available. Launch the IDRAC/DRAC Console to debug further.

Element properties:

TargetDell.RemoteAccess.iDRAC7
CategoryAvailabilityHealth
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
RemotableTrue
Alert Message
Dell Remote Access : Power Supply audit failure or critical event.
Event Description: {0}

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource System.NetworkManagement.SnmpTrapEventProvider Default
Alert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="Dell.iDRAC7.SNMPTrap.8329" Enabled="true" Target="DAD!Dell.RemoteAccess.iDRAC7" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="DS" TypeID="Node!System.NetworkManagement.SnmpTrapEventProvider">
<IP>$Target/Property[Type="DAD!Dell.RemoteAccess.RAC"]/IPAddress$</IP>
<OIDProps>
<OIDProp>.1.3.6.1.4.1.674.10892.5.3.2.1.0.8329</OIDProp>
</OIDProps>
<EventOriginId>$Target/Id$</EventOriginId>
<PublisherId>$Target/Id$</PublisherId>
<PublisherName>iDRAC</PublisherName>
<Channel>SnmpEvent</Channel>
<LoggingComputer/>
<EventNumber>8329</EventNumber>
<EventCategory>5</EventCategory>
<EventLevel>10</EventLevel>
<UserName/>
<Params/>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Dell.iDRAC7.SNMPTrap.8329.Rule"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[3]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[6]/Value$</SuppressionValue>
<SuppressionValue>$Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[8]/Value$</SuppressionValue>
</Suppression>
<Custom1>Alert Message ID = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[3]/Value$ </Custom1>
<Custom2>Alert Message = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[4]/Value$ </Custom2>
<Custom3>Alert Status = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[5]/Value$ </Custom3>
<Custom4>Alert Service Tag = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[6]/Value$ </Custom4>
<Custom5>Alert FQDN = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[7]/Value$ </Custom5>
<Custom6>Alert FQDD = $Data/EventData/DataItem/SnmpVarBinds/SnmpVarBind[8]/Value$ </Custom6>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>