Monitor the standby power supply status.
This monitor reports the availability of standby power supplies in EMC storage system enclosures. Power supplies are components of storage enclosures that convert AC line voltage into DC voltage, which is required for the storage enclosure to operate. They are typically installed in pairs for redundancy.
This monitor will always show as healthy if the target power supply is not a standby power supply.
See the alert for details about the power supply locations and states.
An unhealthy state can occur if a power supply physically fails, is disconnected from line voltage, improperly installed, or removed from a storage enclosure.
Confirm the correct AC line is connected to the power supply and that it is secure in its enclosure.
For more information about this storage system component, refer to your storage system documentation.
For more information or technical support, refer to DELLEMC Online Support at support.emc.com.
Target | EMC.SI.PowerSupply | ||
Parent Monitor | System.Health.AvailabilityState | ||
Category | AvailabilityHealth | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | MatchMonitorHealth | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | EMC.SI.Entity.Status.MonitorType | ||
Remotable | True | ||
Accessibility | Public | ||
Alert Message |
| ||
RunAs | Default |
<UnitMonitor ID="EMC.SI.StandbyPowerSupply.Status.Monitor" Accessibility="Public" Enabled="true" Target="ESILib!EMC.SI.PowerSupply" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="EMC.SI.Entity.Status.MonitorType" ConfirmDelivery="true">
<Category>AvailabilityHealth</Category>
<AlertSettings AlertMessage="EMC.SI.StandbyPowerSupply.Status.Monitor_AlertMessageResourceID">
<AlertOnState>Warning</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>MatchMonitorHealth</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Target/Property[Type="ESILib!EMC.SI.StorageDevice"]/DescriptiveId$</AlertParameter1>
<AlertParameter2>$Data/Context/Property[@Name='HealthStateDetails']$</AlertParameter2>
<AlertParameter3>$Data/Context/Property[@Name='OperationalStatus']$</AlertParameter3>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="Success" MonitorTypeStateID="Success" HealthState="Success"/>
<OperationalState ID="Warning" MonitorTypeStateID="Warning" HealthState="Warning"/>
<OperationalState ID="Error" MonitorTypeStateID="Error" HealthState="Error"/>
</OperationalStates>
<Configuration>
<ESIServiceHost>$Target/Host/Host/Host/Property[Type="ESILib!EMC.SI.ESIService"]/ESIServiceHost$</ESIServiceHost>
<Port>$Target/Host/Host/Host/Property[Type="ESILib!EMC.SI.ESIService"]/Port$</Port>
<ProxyServer>$Target/Host/Host/Host/Property[Type="ESILib!EMC.SI.ESIService"]/ProxyServer$</ProxyServer>
<BypassList>$Target/Host/Host/Host/Property[Type="ESILib!EMC.SI.ESIService"]/BypassList$</BypassList>
<IgonreCertificateErrors>$Target/Host/Host/Host/Property[Type="ESILib!EMC.SI.ESIService"]/IgonreCertificateErrors$</IgonreCertificateErrors>
<HTTPStoHTTPFallBack>$Target/Host/Host/Host/Property[Type="ESILib!EMC.SI.ESIService"]/HTTPStoHTTPFallBack$</HTTPStoHTTPFallBack>
<UserName>$Target/Host/Host/Host/Property[Type="ESILib!EMC.SI.ESIService"]/UserName$</UserName>
<Password>$Target/Host/Host/Host/Property[Type="ESILib!EMC.SI.ESIService"]/Password$</Password>
<HostComponentId>$Target/Host/Property[Type="ESILib!EMC.SI.StorageSystemEnclosure"]/EnclosureId$</HostComponentId>
<EntityClass>StandbyPowerSupply</EntityClass>
<EntityID>$Target/Property[Type="ESILib!EMC.SI.PowerSupply"]/PowerSupplyId$</EntityID>
<IntervalSeconds>307</IntervalSeconds>
<TimeoutSeconds>600</TimeoutSeconds>
<SyncTime/>
<DebugLevel>$Target/Property[Type="ESILib!EMC.SI.StorageDevice"]/DebugLevel$</DebugLevel>
</Configuration>
</UnitMonitor>