3.3V power failed for disk.
RAID_MIB_10052: 3.3V power failed for disk
The following problem causes this event
3.3V power failed for disk.
1) Check whether all cables are correctly connected to the disk backplane connectors. 2) Replace affected disk.
To view the details of the problem:
Launch ServerView System Monitor
Launch ServerView Remote Management iRMC
Target | Fujitsu.Servers.PRIMERGY.Linux.Server | ||
Category | EventCollection | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | High | ||
Remotable | True | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
EventDS | DataSource | Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.10052" Enabled="true" Target="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.Server" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="EventDS" TypeID="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource">
<Host>$Target/Property[Type="FTSLIB!Fujitsu.ServerView.Server"]/NetworkName$</Host>
<LogFile>/var/log/messages</LogFile>
<RegExpFilter>\s+ServerView\s+RAID:\s+\[10052\]\s*\[CRITICAL\]</RegExpFilter>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertMessageId>$MPElement[Name="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.10052.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/Property[@Name='Date']$</AlertParameter1>
<AlertParameter2>$Data/Property[@Name='Details']$</AlertParameter2>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/Property[@Name='ID']$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>