Enclosure not responding.
RAID_MIB_10331: Enclosure not responding
The following problem causes this event
Enclosure not responding.
1) Check data cable(s) to enclosure. 2) Check if enclosure is running.
To view the details of the problem:
Launch ServerView System Monitor
Launch ServerView Remote Management iRMC
Target | Fujitsu.Servers.PRIMERGY.Linux.Server | ||
Category | EventCollection | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | High | ||
Remotable | True | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
EventDS | DataSource | Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.10331" Enabled="true" Target="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.Server" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="EventDS" TypeID="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource">
<Host>$Target/Property[Type="FTSLIB!Fujitsu.ServerView.Server"]/NetworkName$</Host>
<LogFile>/var/log/messages</LogFile>
<RegExpFilter>\s+ServerView\s+RAID:\s+\[10331\]\s*\[MAJOR\]</RegExpFilter>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.10331.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/Property[@Name='Date']$</AlertParameter1>
<AlertParameter2>$Data/Property[@Name='Details']$</AlertParameter2>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/Property[@Name='ID']$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>