Power state change failed on disk (from transition to stopped).
RAID_MIB_10828: Power state change failed on disk (from transition to stopped)
The following problem causes this event
Power state change failed on disk (from transition to stopped).
Replace affected disk.
To view the details of the problem:
Launch ServerView System Monitor
Launch ServerView Remote Management iRMC
Target | Fujitsu.Servers.PRIMERGY.Linux.Server | ||
Category | EventCollection | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
EventDS | DataSource | Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.10828" Enabled="true" Target="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.Server" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="EventDS" TypeID="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource">
<Host>$Target/Property[Type="FTSLIB!Fujitsu.ServerView.Server"]/NetworkName$</Host>
<LogFile>/var/log/messages</LogFile>
<RegExpFilter>\s+ServerView\s+RAID:\s+\[10828\]\s*\[MINOR\]</RegExpFilter>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.10828.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/Property[@Name='Date']$</AlertParameter1>
<AlertParameter2>$Data/Property[@Name='Details']$</AlertParameter2>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/Property[@Name='ID']$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>