Write regulation activated due to high temperature.
RAID_MIB_10973: Write regulation activated due to high temperature
The following problem causes this event
Write regulation activated due to high temperature.
If this condition persists, increase air flow, lower room temperature or reduce write load.
To view the details of the problem:
Launch ServerView System Monitor
Launch ServerView Remote Management iRMC
Target | Fujitsu.Servers.PRIMERGY.Linux.Server | ||
Category | EventCollection | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
EventDS | DataSource | Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.10973" Enabled="true" Target="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.Server" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="EventDS" TypeID="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource">
<Host>$Target/Property[Type="FTSLIB!Fujitsu.ServerView.Server"]/NetworkName$</Host>
<LogFile>/var/log/messages</LogFile>
<RegExpFilter>\s+ServerView\s+RAID:\s+\[10973\]\s*\[MINOR\]</RegExpFilter>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.10973.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/Property[@Name='Date']$</AlertParameter1>
<AlertParameter2>$Data/Property[@Name='Details']$</AlertParameter2>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/Property[@Name='ID']$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>