Wear level count of disk above threshold.
RAID_MIB_11090: Wear level count of disk above threshold
The following problem causes this event
Wear level count of disk above threshold.
1) Backup your data. 2) Replace affected disk as soon as possible to avoid malfunction (read only mode).
To view the details of the problem:
Launch ServerView System Monitor
Launch ServerView Remote Management iRMC
Target | Fujitsu.Servers.PRIMERGY.Linux.Server | ||
Category | EventCollection | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
EventDS | DataSource | Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.11090" Enabled="true" Target="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.Server" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="EventDS" TypeID="FTSLin!Fujitsu.Servers.PRIMERGY.Linux.LogFile.DataSource">
<Host>$Target/Property[Type="FTSLIB!Fujitsu.ServerView.Server"]/NetworkName$</Host>
<LogFile>/var/log/messages</LogFile>
<RegExpFilter>\s+ServerView\s+RAID:\s+\[11090\]\s*\[MINOR\]</RegExpFilter>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Fujitsu.Servers.PRIMERGY.Linux.RAIDMIB.Alerts.11090.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/Property[@Name='Date']$</AlertParameter1>
<AlertParameter2>$Data/Property[@Name='Details']$</AlertParameter2>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/Property[@Name='ID']$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>