Disk failed since it never entered ready state,
RAID_MIB_10711: Disk failed since it never entered ready state.
The following problem causes this event
Disk failed since it never entered ready state.
Replace affected disk.
To view the details of the problem:
Launch ServerView RAID Manager
Launch ServerView System Monitor
Target | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | ||
Category | EventCollection | ||
Enabled | True | ||
Event_ID | 10711 | ||
Event Source | ServerView Raid | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | High | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | Application |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10711" Enabled="true" Target="FTSWIN!Fujitsu.Servers.PRIMERGY.Windows.RaidManagement" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="FTSWIN!Fujitsu.Servers.PRIMERGY.Windows.ManagementClientSoftware"]/ServerName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">10711</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">ServerView Raid</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10711.AlertMessage"]$</AlertMessageId>
<AlertParameters/>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>