Any automatic fail-safe configuration stopped. The Boot Configuration Data (BCD) is not accessible. For the x10sureIS failover processing it is mandatory to access the BCD data. Please contact ... [DDM_5207]

Fujitsu.Servers.PRIMERGY.Windows.Rules.DDM_5207 (Rule)

Please the check the configuration or contact system operator immediately to solve this problem. (Additional a message box is displayed on all active terminals.)

Knowledge Base article:

Summary

[DDM_5207] Any automatic fail-safe configuration stopped. The Boot Configuration Data (BCD) is not accessible. For the x10sureIS failover processing it is mandatory to access the BCD data. Please contact system operator immediately to solve this problem.

Causes

This event is caused by the following problem:

Resolutions

To view the details of the problem:

Element properties:

TargetFujitsu.Servers.PRIMERGY.Windows.Server
CategoryEventCollection
EnabledTrue
Event_ID5207
Event Sourceddm
Alert GenerateTrue
Alert SeverityError
Alert PriorityHigh
RemotableTrue
Alert Message
[DDM_5207] Any automatic fail-safe configuration stopped. The Boot Configuration Data (BCD) is not accessible. For the x10sureIS failover processing it is mandatory to access the BCD data. Please contact ...
Please the check the configuration or contact system operator immediately to solve this problem. (Additional a message box is displayed on all active terminals.)
Event LogSystem

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
Alert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="Fujitsu.Servers.PRIMERGY.Windows.Rules.DDM_5207" Enabled="true" Target="FTSWIN!Fujitsu.Servers.PRIMERGY.Windows.Server" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="FTSLIB!Fujitsu.ServerView.Server"]/NetworkName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">5207</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">ddm</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Fujitsu.Servers.PRIMERGY.Windows.Rules.DDM_5207.AlertMessage"]$</AlertMessageId>
<AlertParameters/>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>