A redundant fan failed in cabinet of server. System can become critical if another fan in this group fails.
SC2_MIB_12015: A redundant fan failed in cabinet
This event is caused by the following problem:
The indicated redundant fan failed
Verify that the system fan is correctly mounted.
Check if latest BIOS revision and BMC firmware is installed.
If the problem persists replace the corresponding fan due to the instructions within the service manual.
Replace defect fan because the system can become critical if another fan in this group fails
To view the details of the problem:
Launch ServerView System Monitor
Launch ServerView Remote Management iRMC
Target | Fujitsu.Servers.PRIMERGY.Windows.Server | ||
Category | EventCollection | ||
Enabled | True | ||
Event_ID | 12015 | ||
Event Source | ServerView Agents | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | High | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | Application |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12015" Enabled="true" Target="FTSWIN!Fujitsu.Servers.PRIMERGY.Windows.Server" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="FTSLIB!Fujitsu.ServerView.Server"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">12015</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">ServerView Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12015.AlertMessage"]$</AlertMessageId>
<AlertParameters/>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>