Drive Array Spare Drive failed.
The drive array spare drive has failed.
This could be caused by the following:
Spare Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.
If the spare drive status is failed, replace the drive.
For additional troubleshooting, the following tasks are available:
HPE System Management Homepage
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Publisher | Log Message |
---|---|---|
1063 | Storage Agents | Drive Array Spare Drive Status Change. The spare drive in slot %4, port %5, bay %6 has a new status of %2. |
See the latest information about HPE ProLiant Management Packs:
Insight Control for Microsoft System Center documentation
HPE ProLiant Servers SNMP Management Pack
Target | HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerStorage |
Category | Alert |
Enabled | True |
Alert Generate | True |
Alert Severity | Error |
Alert Priority | High |
Remotable | True |
Event Log | System |
Comment | Mom2005ID='{ED8F6317-CCCB-4BB9-AC7B-4B76D2DAE92C}' |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
_907D4578_146C_11D3_AB21_00A0C98620CE_ | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Servers.ProLiant.SNMP.Drive_Array_Spare_Drive_failed._5_Rule" Target="HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerStorage" Enabled="true" Comment="Mom2005ID='{ED8F6317-CCCB-4BB9-AC7B-4B76D2DAE92C}'">
<Category>Alert</Category>
<DataSources>
<DataSource ID="_907D4578_146C_11D3_AB21_00A0C98620CE_" Comment="{907D4578-146C-11D3-AB21-00A0C98620CE}" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Storage Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>EventLevel</XPathQuery>
</ValueExpression>
<Operator>LessEqual</Operator>
<ValueExpression>
<Value>2</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>1063</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName>HPE Windows (SNMP) Drive Array Spare Drive failed.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>