External Array Logical Drive failed.
The external array logical drive has failed.
This could be caused by the following:
External Array Logical Drive Status Change. This trap signifies that the agent has detected a change in the status of an external array logical drive. The variable cpqFcaLogDrvStatus indicates the current logical drive status.
If the logical drive status is failed, examine the array for failed drives that need replacement.
For additional troubleshooting, the following tasks are available:
HPE System Management Homepage
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Publisher | Log Message |
---|---|---|
1145 | Storage Agents | External Array Logical Drive Status Change. Logical drive number %5 on array "%4" has a new status of %6. |
See the latest information about HPE ProLiant Management Packs:
Insight Control for Microsoft System Center documentation
HPE ProLiant Servers SNMP Management Pack
Target | HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerStorage |
Category | Alert |
Enabled | True |
Alert Generate | True |
Alert Severity | Error |
Alert Priority | High |
Remotable | True |
Event Log | System |
Comment | Mom2005ID='{06BAB285-15CB-42AF-88EC-FDDDE78F7927}' |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
_907D4578_146C_11D3_AB21_00A0C98620CE_ | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Servers.ProLiant.SNMP.External_Array_Logical_Drive_failed._5_Rule" Target="HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerStorage" Enabled="true" Comment="Mom2005ID='{06BAB285-15CB-42AF-88EC-FDDDE78F7927}'">
<Category>Alert</Category>
<DataSources>
<DataSource ID="_907D4578_146C_11D3_AB21_00A0C98620CE_" Comment="{907D4578-146C-11D3-AB21-00A0C98620CE}" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Storage Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>EventLevel</XPathQuery>
</ValueExpression>
<Operator>LessEqual</Operator>
<ValueExpression>
<Value>2</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>1145</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName>HPE Windows (SNMP) External Array Logical Drive failed.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>