HPE Windows (SNMP) PCI adapter failed.

HewlettPackard.Servers.ProLiant.SNMP.PCI_adapter_failed._5_Rule (Rule)

PCI adapter failed. A Hot Plug Slot Board has failed to powerup.

Knowledge Base article:

Summary

The PCI adapter has failed.

Causes

This could be caused by the following:

Resolutions

Ensure that the board and all cables are installed correctly and that the board type and revision are the same as the replaced board.

For additional troubleshooting, the following tasks are available:

Related Events

The following are monitored NT Event Log entries by this rule:

Event ID

Publisher

Log Message

1142

Server Agents

System Information Agent: Health: Hot Plug PCI Board Failed. A hot plug PCI adapter has failed to power up. Ensure the board and all cables are installed correctly.
Chassis: '%4'; Slot: '%5'
[SNMP TRAP: 2010 in CPQSINFO.MIB]

Related Links

See the latest information about HPE ProLiant Management Packs:

Insight Control for Microsoft System Center documentation

Management Pack Information

HPE ProLiant Servers SNMP Management Pack

Element properties:

TargetHewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerOthers
CategoryAlert
EnabledTrue
Event_ID1142
Event SourceServer Agents
Alert GenerateTrue
Alert SeverityError
Alert PriorityHigh
RemotableTrue
Event LogSystem
CommentMom2005ID='{F82DBCA6-24DD-4014-B1C8-5BE58B9D323E}'

Member Modules:

ID Module Type TypeId RunAs 
_907D4578_146C_11D3_AB21_00A0C98620CE_ DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="HewlettPackard.Servers.ProLiant.SNMP.PCI_adapter_failed._5_Rule" Target="HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerOthers" Enabled="true" Comment="Mom2005ID='{F82DBCA6-24DD-4014-B1C8-5BE58B9D323E}'">
<Category>Alert</Category>
<DataSources>
<DataSource ID="_907D4578_146C_11D3_AB21_00A0C98620CE_" Comment="{907D4578-146C-11D3-AB21-00A0C98620CE}" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Server Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>1142</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName>HPE Windows (SNMP) PCI adapter failed.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>