Power sub system degraded. (consolidation)
The power subsystem has degraded. (consolidation)
This could be caused by the following:
The Fault Tolerant Power Supply subsystem condition has been set to degraded.
A Fault Tolerant Power Supply has been removed from the specified chassis and bay location.
The Fault Tolerant Power Supplies have lost redundancy for the specified chassis.
The Fault Tolerant Power Supply condition has been set to degraded for the specified chassis and bay location.
Replace any failed or missing fans.
For additional troubleshooting, the following tasks are available:
HPE System Management Homepage
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Publisher | Log Message |
---|---|---|
1103 | Server Agents |
System Information Agent: Health: The Fault Tolerant Power Sub-system has been set to Degraded. Check power connections and replace the power supply as needed. |
1128 | Server Agents |
System Information Agent: Health: The fault tolerant power supply has been removed. A hot-plug Fault Tolerant Power Supply has been removed from the system. |
1126 | Server Agents |
System Information Agent: Health: The fault tolerant power supply subsystem has lost redundancy. Restore power or replace any failed or missing power supplies. |
1124 | Server Agents |
System Information Agent: Health: The fault tolerant power supply subsystem is in a degraded state. Restore power or replace the failed power supply. |
See the latest information about HPE ProLiant Management Packs:
Insight Control for Microsoft System Center documentation
HPE ProLiant Servers SNMP Management Pack
Target | HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPPowerSupplies |
Category | Alert |
Enabled | False |
Event Source | Server Agents |
Alert Generate | True |
Alert Severity | Warning |
Alert Priority | High |
Remotable | True |
Event Log | System |
Comment | Mom2005ID='{2B434508-6A92-4465-9C9C-5E4E377C3589}' |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
_907D4578_146C_11D3_AB21_00A0C98620CE_ | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Servers.ProLiant.SNMP.Power_sub_system_degraded._5_Rule" Target="HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPPowerSupplies" Enabled="false" Comment="Mom2005ID='{2B434508-6A92-4465-9C9C-5E4E377C3589}'">
<Category>Alert</Category>
<DataSources>
<DataSource ID="_907D4578_146C_11D3_AB21_00A0C98620CE_" Comment="{907D4578-146C-11D3-AB21-00A0C98620CE}" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Server Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>MatchesMOM2005BooleanRegularExpression</Operator>
<Pattern>^(1103|1128|1126|1124)$</Pattern>
</RegExExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>HPE Windows (SNMP) Power sub-system degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>