HPE Windows (SNMP) Rack enclosure power subsystem degraded.

HewlettPackard.Servers.ProLiant.SNMP.Rack_enclosure_power_subsystem_degraded._5_Rule (Rule)

Rack enclosure power subsystem degraded.

Knowledge Base article:

Summary

The rack enclosure power subsystem has degraded.

Causes

This could be caused by the following:

Resolutions

Check the enclosure and/or blade power connections and reset the fuse.
Check server enclosure connections or add power supplies.
Check the cabling of the power enclosure.
Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed.
Remove the extra power enclosure.

For additional troubleshooting, the following tasks are available:

Related Events

The following are monitored NT Event Log entries by this rule:

Event ID

Publisher

Log Message

1169

Server Agents

Rack Information Agent: Fuse or Breaker Tripped
The fuse has been tripped.
User Action: Check enclosure and / or blade power connections and reset the fuse.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Fuse/Breaker Location '%7';
Enclosure Spare Part Number '%8';
Enclosure Serial Number '%9';
Trap Sequence Number '%10'
[SNMP TRAP: 22027 in CPQRACK.MIB]

1167

Server Agents

Rack Information Agent: Inadequate Power To Power On.
There is not enough power to power on the server blade. The power enclosure micro-controller was not found.
User Action: Check the server enclosure connections or add power supplies.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Blade Position '%7';
Blade Spare Part Number '%8';
Enclosure Serial Number '%9';
Trap Sequence Number '%10'
[SNMP TRAP: 22025 in CPQRACK.MIB]

1166

Server Agents

Rack Information Agent: Inadequate Power To Power On
There is not enough power to power on the server blade. The server enclosure micro-controller was not found.
User Action: Check server enclosure connections or add power supplies.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Blade Position '%7';
Blade Spare Part Number '%8';
Enclosure Serial Number '%9';
Trap Sequence Number '%10'
[SNMP TRAP: 22024 in CPQRACK.MIB]

1178

Server Agents

Rack Information Agent: Power Subsystem Configuration Error
The power subsystem has been improperly configured.
User Action: Check the cabling of the power enclosure.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Enclosure Serial Number '%7';
Enclosure Spare Part Number '%8';
Trap Sequence Number '%9'
[SNMP TRAP: 22036 in CPQRACK.MIB]

1173

Server Agents

Rack Information Agent: Power Subsystem DC Power Problem
There is a power subsystem DC power problem for this enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Check the power bus bar for tripped breakers.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Enclosure Serial Number '%7';
Enclosure Spare Part Number '%8';
Trap Sequence Number '%9'
[SNMP TRAP: 22031 in CPQRACK.MIB]

1174

Server Agents

Rack Information Agent: Power Subsystem Facility AC Power Problem
The AC facility input power has been exceeded for this power enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Enclosure Serial Number '%7';
Enclosure Spare Part Number '%8';
Trap Sequence Number '%9'
[SNMP TRAP: 22032 in CPQRACK.MIB]

1175

Server Agents

Rack Information Agent: Power Subsystem Unknown Power Consumption
There is an unknown power consumer drawing power.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Serial Number '%6';
Trap Sequence Number '%7'
[SNMP TRAP: 22033 in CPQRACK.MIB]

1172

Server Agents

Rack Information Agent: Rack Power Subsystem Not Load Balanced
The power subsystem is out of balance for this power enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Enclosure Serial Number '%7';
Enclosure Spare Part Number '%8';
Trap Sequence Number '%9'
[SNMP TRAP: 22030 in CPQRACK.MIB]

1177

Server Agents

Rack Information Agent: Power Subsystem Too Many Power Enclosures
The maximum number of power enclosures has been exceeded.
User Action: Remove the extra power enclosure.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Enclosure Serial Number '%7';
Trap Sequence Number '%8'
[SNMP TRAP: 22035 in CPQRACK.MIB]

Related Links

See the latest information about HPE ProLiant Management Packs:

Insight Control for Microsoft System Center documentation

Management Pack Information

HPE ProLiant Servers SNMP Management Pack

Element properties:

TargetHewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerOthers
CategoryAlert
EnabledTrue
Event SourceServer Agents
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityHigh
RemotableTrue
Event LogSystem
CommentMom2005ID='{4AA5BC17-7527-40E3-8957-A6C00EFB916F}'

Member Modules:

ID Module Type TypeId RunAs 
_907D4578_146C_11D3_AB21_00A0C98620CE_ DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="HewlettPackard.Servers.ProLiant.SNMP.Rack_enclosure_power_subsystem_degraded._5_Rule" Target="HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerOthers" Enabled="true" Comment="Mom2005ID='{4AA5BC17-7527-40E3-8957-A6C00EFB916F}'">
<Category>Alert</Category>
<DataSources>
<DataSource ID="_907D4578_146C_11D3_AB21_00A0C98620CE_" Comment="{907D4578-146C-11D3-AB21-00A0C98620CE}" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Server Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>MatchesMOM2005BooleanRegularExpression</Operator>
<Pattern>^(1169|1167|1166|1178|1173|1174|1175|1172|1177)$</Pattern>
</RegExExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>HPE Windows (SNMP) Rack enclosure power subsystem degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>