Rack enclosure temperature failed. (consolidation)
The rack enclosure temperature has failed. (consolidation)
This could be caused by the following:
The enclosure temperature status has been set to failed. This trap signifies that a enclosure temperature sensor has been tripped indicating an overheat condition.
Shutdown the enclosure and possibly the rack as soon as possible. Ensure all fans are working properly and that air flow in the rack has not been blocked.
For additional troubleshooting, the following tasks are available:
HPE System Management Homepage
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Publisher | Log Message |
---|---|---|
1147 | Server Agents |
Rack Information Agent: Rack Enclosure Overheated |
See the latest information about HPE ProLiant Management Packs:
Insight Control for Microsoft System Center documentation
HPE ProLiant Servers SNMP Management Pack
Target | HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerOthers |
Category | Alert |
Enabled | False |
Event_ID | 1147 |
Event Source | Server Agents |
Alert Generate | True |
Alert Severity | Error |
Alert Priority | High |
Remotable | True |
Event Log | System |
Comment | Mom2005ID='{9E2A6468-AD82-4C52-9653-34AAC104B6C4}' |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
_907D4578_146C_11D3_AB21_00A0C98620CE_ | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Servers.ProLiant.SNMP.Rack_enclosure_temperature_failed._5_Rule" Target="HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerOthers" Enabled="false" Comment="Mom2005ID='{9E2A6468-AD82-4C52-9653-34AAC104B6C4}'">
<Category>Alert</Category>
<DataSources>
<DataSource ID="_907D4578_146C_11D3_AB21_00A0C98620CE_" Comment="{907D4578-146C-11D3-AB21-00A0C98620CE}" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Server Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>1147</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName>HPE Windows (SNMP) Rack enclosure temperature failed.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>