HPE Windows (SNMP) Rack power subsystem not redundant.

HewlettPackard.Servers.ProLiant.SNMP.Rack_power_subsystem_not_redundant._5_Rule (Rule)

Rack power subsystem not redundant. The rack power subsystem is no longer in a redundant state.

Knowledge Base article:

Summary

The rack power subsystem is not redundant.

Causes

This could be caused by the following:

Resolutions

Replace any failed power supplies as soon as possible to return the system to a redundant state.

For additional troubleshooting, the following tasks are available:

Related Events

The following are monitored NT Event Log entries by this rule:

Event ID

Publisher

Log Message

1160

Server Agents

Rack Information Agent: Rack Power Subsystem Not Redundant
The rack power subsystem is no longer in a redundant state.
User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Enclosure Serial Number '%7';
Trap Sequence Number '%8'
[SNMP TRAP: 22018 in CPQRACK.MIB]

Related Links

See the latest information about HPE ProLiant Management Packs:

Insight Control for Microsoft System Center documentation

Management Pack Information

HPE ProLiant Servers SNMP Management Pack

Element properties:

TargetHewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerOthers
CategoryAlert
EnabledTrue
Event_ID1160
Event SourceServer Agents
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityHigh
RemotableTrue
Event LogSystem
CommentMom2005ID='{9A80071B-F856-492C-8683-C0164F3F491F}'

Member Modules:

ID Module Type TypeId RunAs 
_907D4578_146C_11D3_AB21_00A0C98620CE_ DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="HewlettPackard.Servers.ProLiant.SNMP.Rack_power_subsystem_not_redundant._5_Rule" Target="HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerOthers" Enabled="true" Comment="Mom2005ID='{9A80071B-F856-492C-8683-C0164F3F491F}'">
<Category>Alert</Category>
<DataSources>
<DataSource ID="_907D4578_146C_11D3_AB21_00A0C98620CE_" Comment="{907D4578-146C-11D3-AB21-00A0C98620CE}" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Server Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>1160</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>HPE Windows (SNMP) Rack power subsystem not redundant.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>