HP Windows (WMI) SAS storage system fan failed.

HewlettPackard.Servers.ProLiant.WMI.SAS_Fan_status_Error_Rule (Rule)

A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.

Knowledge Base article:

Summary

A fan status has changed to Error.

Causes

This could be caused by the following:

Resolutions

Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.

For additional troubleshooting, the following tasks are available:

Related Events

The following are monitored NT Event Log entries by this rule:

Event ID

Publisher

Log Message

306

HP SAS

A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.

User Action

Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.

(WBEM Indication Properties)

Related Links

See the latest information about HP ProLiant Management Packs:

Insight Control for Microsoft System Center documentation

Management Pack Information

HP ProLiant Servers WMI Management Pack

Element properties:

TargetHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage
CategoryAlert
EnabledTrue
Event_ID306
Event SourceHP SAS
Alert GenerateTrue
Alert SeverityError
Alert PriorityHigh
RemotableTrue
Event LogSystem

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="HewlettPackard.Servers.ProLiant.WMI.SAS_Fan_status_Error_Rule" Target="HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage" Enabled="true">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP SAS</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">306</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName>HP Windows (WMI) SAS storage system fan failed.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>