A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.
A temperature sensor status has changed to Warning Condition.
This could be caused by the following:
A Storage Enclosure Temperature sensor status has changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.
Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.
For additional troubleshooting, the following tasks are available:
HP System Management Homepage
HP Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Publisher | Log Message |
---|---|---|
308 | HP SAS | A Storage Enclosure Temperature sensor status has changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally. User Action Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary. (WBEM Indication Properties) |
See the latest information about HP ProLiant Management Packs:
Insight Control for Microsoft System Center documentation
HP ProLiant Servers WMI Management Pack
Target | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage |
Category | Alert |
Enabled | True |
Event_ID | 308 |
Event Source | HP SAS |
Alert Generate | True |
Alert Severity | Warning |
Alert Priority | High |
Remotable | True |
Event Log | System |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Servers.ProLiant.WMI.SAS_Temperature_sensor_status_Warning_Condition_Rule" Target="HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage" Enabled="true">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP SAS</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">308</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>HP Windows (WMI) SAS storage system temperature degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>