HP Windows (WMI) SAS storage system temperature degraded.

HewlettPackard.Servers.ProLiant.WMI.SAS_Temperature_sensor_status_Warning_Condition_Rule (Rule)

A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.

Knowledge Base article:

Summary

A temperature sensor status has changed to Warning Condition.

Causes

This could be caused by the following:

Resolutions

Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.

For additional troubleshooting, the following tasks are available:

Related Events

The following are monitored NT Event Log entries by this rule:

Event ID

Publisher

Log Message

308

HP SAS

A Storage Enclosure Temperature sensor status has changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.

User Action

Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.

(WBEM Indication Properties)

Related Links

See the latest information about HP ProLiant Management Packs:

Insight Control for Microsoft System Center documentation

Management Pack Information

HP ProLiant Servers WMI Management Pack

Element properties:

TargetHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage
CategoryAlert
EnabledTrue
Event_ID308
Event SourceHP SAS
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityHigh
RemotableTrue
Event LogSystem

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="HewlettPackard.Servers.ProLiant.WMI.SAS_Temperature_sensor_status_Warning_Condition_Rule" Target="HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage" Enabled="true">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP SAS</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">308</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>HP Windows (WMI) SAS storage system temperature degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>