HPE Windows (WMI) Smart Array controller cache status not configured.

HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_not_configured (Rule)

A Smart Array Controller Cache status has changed to not configured. This may be caused by a configuration change.

Knowledge Base article:

Summary

Array controller cache status not configured.

Causes

This could be caused by the following:

Resolutions

Check the cache controller error code and run diagnostics.

For additional troubleshooting, the following tasks are available:

Related Events

The following are monitored NT Event Log entries by this rule:

Event ID

Publisher

Log Message

12

HPE Smart Array

A Smart Array Controller Cache status has changed to not configured. This may be caused by a configuration change.

User Action

Check the cache controller error code and run diagnostics.

(WBEM Indication Properties)

Related Links

See the latest information about HPE ProLiant Management Packs:

Insight Control for Microsoft System Center documentation

Management Pack Information

HPE ProLiant Servers WMI Management Pack

Element properties:

TargetHewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage
CategoryAlert
EnabledTrue
Event_ID12
Event SourceHP Smart Array
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityHigh
RemotableTrue
Event LogSystem

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_not_configured" Target="HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage" Enabled="true">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP Smart Array</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">12</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>HPE Windows (WMI) Smart Array controller cache status not configured.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>